V3.0 HW Upgrade (80SD100XS.C04X-01)

DWL@DWL10000082669

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.6.1.0 * 11.02.2013 993 KB EXE AS3.0_HW_80SD100XS.C04X-01.exe
Popis V3.0 HW Upgrade (80SD100XS.C04X-01)

Revision information 80SD100XS.C04X-01

Version 1.6.1.0:

ID: 319020
Module bootup timeout configured
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 320785
Accelerated firmware update.
Allows reliable firmware update behind CANIO bus controllers.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42880_1.fw(12), 1\42880_2.fw(12), 1\42880_3.fw(12)

Version 1.6.0.0:

ID: 288435 / Support ID: 400084530
Encoder position should be displayed at PosVal03, if SDC information is setto "on"
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 301445
Support for HW-Variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42880_1.fw(11), 1\42880_2.fw(11), 1\42880_3.fw(11)

Version 1.5.3.0:

ID: 296370 / Support ID: 400087355
80SD100XS.C04X-01: Erroneous Detection of Short Circuit between Motor-Phaseand Ground
Due to a Firmware-Error the activation of the Controller could be blocked under certain circumstances because of a wrongly assumed Short Circuit to Ground
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42880_1.fw(11), 1\42880_2.fw(11)

Version 1.5.2.0:

ID: 290355 / Support ID: 400082483
In rare cases ACOPOSmicro generated an erroneous status indication (UZKStatus = not OK).
Also high motor currents in conjunction with tolerances of electronic components could lead to module internal disturbances which in consequence could generate error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42880_1.fw(10), 1\42880_2.fw(10)

Version 1.5.1.0:

ID: 272445 / Support ID: 400049998
Module in undefined state, if no trigger happens in mode -121 (Remaining distance mode)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 272450 / Support ID: 400051695
The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 272455
Ramp mode: Wrong configuratin for referencing speed is possible
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42880_1.fw(9), 1\42880_2.fw(9)

Version 1.4.1.2:

ID: 245875
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42880_1.fw(8), 1\42880_2.fw(8)

Version 1.4.1.1:

ID: 243370
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42880_1.fw(8), 1\42880_2.fw(8)

Version 1.0.0.0:

ID: 195055
Support for the module 80SD100XS.C04X-01
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42880_1.fw(3)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.4.0.0 * 31.03.2016 1 MB EXE AS3.0_HW_80SD100XS.C04X-01.exe