DWL@DWL10000784807
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
|---|---|---|---|---|---|---|
| 2.7.0.0 | * | 15.12.2025 | 3 MB | EXE | AS6_HW_X90SL104.48-S1.exe | |
| Popis |
V6.0 HW Upgrade (X90SL104.48-S1) Revision information X90SL104.48-S1 Version 2.7.0.0: ID: FUVI-11679 Improved synchronization during startup Improved synchronization during startup prevents sporadic FailSafe. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\62661_1.fw(592), 11\62661_1.fw(592) Version 2.5.3.1: ID: 786330 AutomationSoftware 6.x support AutomationSoftware 6.x Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\62661_1.fw(579), 11\62661_1.fw(579) Version 2.5.3.0: ID: 776925 Temperature failures fixed Temperature failures at approx. 60°C ambient temperature have been fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\62661_1.fw(579), 11\62661_1.fw(579) Version 2.5.1.1: ID: 697860 "CLEAR DATA" Safe Commissioning Options "CLEAR DATA" did not delete the data for Safe Commissioning Options with data types SAFEINT, SAFEDINT and SAFEDWORD. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727335 Safe Commissioning Options without SAFEBOOL Logger message "externalmachine options discrepancy" was triggered by mistake when Safe CommissioningOptions where used without using any channel SafeCommissioningOptionsBITxxx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 736430 online project compare Activation of SafeDESIGNER option "Download project source to SL (online project compare)" didn't have any effect (requires mappSafety 5.15). Channeldescription changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\62661_1.fw(577), 11\62661_1.fw(577) Version 2.5.0.0: ID: 715805 Improved stability during boot-up Improved stability during boot-up Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:718050 SafeDESIGNER Variable status improve performance Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 718845 Fix HWX description of SafeLOGIC-to-CPU communication Fix HWX description of SafeLOGIC-to-CPU communication Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 10\62661_1.fw(576) Version2.4.0.0: ID: 708520 Increase maximum switching frequency The maximum switching frequency is increased to the value of the data sheet Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\62661_1.fw(575) Version 2.3.0.1: ID: 691170 increased some system limits Inreased flag counter, number of force variables and sizes of input/output buffers (see technical data). ATTENTION: SafeDESIGNER project must be recompiled and downloaded! It is recommended to perform a SafeKEY-FORMAT before upgrading to thisversion. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 691175 Increased some system limits Double flag memory and flag counter to 256kB respectively16384 flags. Triple memory for safe input data to 6kB. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 703755 "Safe digital outputs" have to be used within SafeDIGNER application Channels configured as " Safe digital output" in Automation Studio can onlybe switched on, if it is also used in SafeDESIGNER application Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 708235 CANopen Safety support Module supports CANopen Safety Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 711370 SafeDOMAIN-to-SafeDOMAIN communication: Connected SafeDOMAIN Provide a Connected SafeDOMAIN (required minimum versions: Automation Runtime A4.90, mappSafety 5.13, X20(c)SL81xx V2.3.0.0) Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\62661_1.fw(574) Version 2.2.0.1: ID: 663695 Support of Safe Commissioning Options ATTENTION: - requires AR E4.71 or A4.72 or higher - if used at least one Safe Commissioning Option with data type BOOL must beused also - use SafeKEY FORMAT to remove Safe Commissioning Options with data types other than BOOL from target Channel description changed: No Configuration description changed:No Firmware changed: No ID: 671740 Configurable test interval for inputs The test interval for inputs is configurable via the parameter "Test interval of input signal path" Channel description changed: No Configuration description changed: No Firmware changed: No ID: 675650 SafeDOMAIN-to-SafeDOMAIN communication Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher) Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 10\62661_1.fw(573) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 2.5.3.1 | * | 07.05.2024 | 3 MB | EXE | AS6_HW_X90SL104.48-S1.exe | |
| Popis |
V6.0 HW Upgrade (X90SL104.48-S1) Revision information X90SL104.48-S1 Version 2.5.3.1: ID: 786330 AutomationSoftware 6.x support AutomationSoftware 6.x Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\62661_1.fw(579), 11\62661_1.fw(579) Version 2.5.3.0: ID: 776925 /Support ID: 400409795 Temperature failures fixed Temperature failures at approx. 60°C ambient temperature have been fixed. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\62661_1.fw(579), 11\62661_1.fw(579) Version 2.5.1.1: ID: 697860 "CLEAR DATA" Safe Commissioning Options "CLEAR DATA" did not delete the data for Safe Commissioning Options with data types SAFEINT, SAFEDINT and SAFEDWORD. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727335 / Support ID: 400353463 Safe Commissioning Options without SAFEBOOL Logger message "external machine options discrepancy" was triggered by mistake when Safe Commissioning Options where used without using any channelSafeCommissioningOptionsBITxxx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 736430 online project compare Activation of SafeDESIGNER option "Downloadproject source to SL (online project compare)" didn't have any effect (requires mappSafety 5.15). Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\62661_1.fw(577), 11\62661_1.fw(577) Version 2.5.0.0: ID: 715805 Improved stability during boot-up Improved stability during boot-up Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 718050 SafeDESIGNER Variable status improve performance Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 718845 Fix HWX description of SafeLOGIC-to-CPU communication Fix HWX description of SafeLOGIC-to-CPU communication Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\62661_1.fw(576) Version 2.4.0.0: ID: 708520 / Support ID: 400335786 Increase maximum switching frequency The maximum switching frequency is increased to the value of the data sheet Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 10\62661_1.fw(575) Version 2.3.0.1: ID: 691170 increased some system limits Inreased flag counter, number of force variables and sizes of input/output buffers (see technical data). ATTENTION: SafeDESIGNER project must be recompiled and downloaded! It is recommended to perform a SafeKEY-FORMAT before upgrading to this version. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 691175 Increased some system limits Double flag memory and flag counter to 256kB respectively 16384 flags. Triple memory for safe input data to 6kB. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 703755 / Support ID: 400335138 "Safe digital outputs" have to be used within SafeDIGNER application Channels configured as " Safe digital output" in Automation Studio can onlybe switched on, if it is also used in SafeDESIGNER application Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 708235 CANopen Safety support Module supports CANopen Safety Channel description changed: No Configuration description changed: Yes Firmware changed:Yes ID: 711370 SafeDOMAIN-to-SafeDOMAIN communication: Connected SafeDOMAIN Provide a Connected SafeDOMAIN (required minimum versions: Automation Runtime A4.90, mappSafety 5.13, X20(c)SL81xx V2.3.0.0) Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\62661_1.fw(574) Version 2.2.0.1: ID: 663695 Support of Safe Commissioning Options ATTENTION: - requires AR E4.71 or A4.72 or higher - if used at least one Safe Commissioning Option with data type BOOL must beused also - use SafeKEY FORMAT to remove Safe Commissioning Options with data types other than BOOL from target Channel description changed: No Configuration description changed: No Firmware changed: No ID: 671740 Configurable test interval for inputs The test interval for inputs is configurable via the parameter "Test interval of input signal path" Channel description changed:No Configuration description changed: No Firmware changed: No ID: 675650 SafeDOMAIN-to-SafeDOMAIN communication Support SafeDOMAIN-to-SafeDOMAIN communication between SafeLOGIC and SafeLOGIC-X (requires mappSafety 5.10 or higher) Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 10\62661_1.fw(573) |
|||||