DWL@DWL10000665843

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.4.0 * 15.11.2022 551 KB EXE AS4_HW_5PC901.TS17-01.exe
Popis V4.9 HW Upgrade (5PC901.TS17-01)

Revision information 5PC901.TS17-01

Version 1.0.4.0:

ID: 759360
New MTCX FW V01.32 for PPC900
New MTCX FW V01.32 for PPC900 with following changes:
- Optimized internal power supply.
- Bugfix: 5AC901.ICAN-01 (SJA1000 CAN).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\64644_0.fw(132)

Version 1.0.3.0:

ID: 752940
Bugfix: Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\64644_0.fw(131)

Version 1.0.2.0:

ID: 749085
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\64644_0.fw(131)

Version 1.0.1.0:

ID: 711340
Preparation for hyperthreading expansionsin the B&R Hypervisor from AS 4.10.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\64644_0.fw(131)

Version 1.0.0.0:

ID: 693530
Support for 5PC901.TS17-xx:
The Panel PC 900 (Skylake) is supported with Automation Studio Version V4.9. As operating system it is mandatory to use at least the version A4.90 of theAutomation Runtime Embedded.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed:Yes
Firmware: 1\64644_0.fw(131)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.3.0 * 10.06.2022 557 KB EXE AS4_HW_5PC901.TS17-01.exe
Popis V4.9 HW Upgrade (5PC901.TS17-01)

Revision information 5PC901.TS17-01

Version 1.0.3.0:

ID: 752940
Bugfix: Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\64644_0.fw(131)

Version 1.0.2.0:

ID: 749085
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware:1\64644_0.fw(131)

Version 1.0.1.0:

ID: 711340
Preparation for hyperthreading expansions in the B&R Hypervisor from AS 4.10.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\64644_0.fw(131)

Version 1.0.0.0:

ID: 693530
Support for 5PC901.TS17-xx:
The Panel PC 900 (Skylake) is supported with Automation Studio Version V4.9. As operating system it is mandatory to use at least the version A4.90 of theAutomation Runtime Embedded.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\64644_0.fw(131)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.2.0 * 03.05.2022 557 KB EXE AS4_HW_5PC901.TS17-01.exe
Popis V4.9 HW Upgrade (5PC901.TS17-01)

Revision information 5PC901.TS17-01.TS17-00

Version 1.0.2.0:

ID: 749085
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\64644_0.fw(131)

Version 1.0.1.0:

ID: 711340
Preparation for hyperthreading expansions in the B&R Hypervisor from AS 4.10.
Channel description changed: No
Configuration description changed: Yes
Firmwarechanged: No
Firmware: 1\64644_0.fw(131)

Version 1.0.0.0:

ID: 693530
Support for 5PC901.TS17-xx:
The Panel PC 900 (Skylake) is supported with Automation Studio Version V4.9. As operating system it is mandatory to use at least the version A4.90 of theAutomation Runtime Embedded.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\64644_0.fw(131)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.0.0 * 20.11.2020 554 KB EXE AS4_HW_5PC901.TS17-01.exe
Popis V4.9 HW Upgrade (5PC901.TS17-01)

Revision information 5PC901.TS17-00

Version 1.0.0.0:

ID: 693530
Support for 5PC901.TS17-xx:
The Panel PC 900 (Skylake) is supported with Automation Studio Version V4.9. As operating system it is mandatory to use at least the version A4.90 of theAutomation Runtime Embedded.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\64644_0.fw(131)