DWL@DWL10000604630
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.6.0.0 | * | 05.03.2024 | 2 MB | EXE | AS4_HW_X67SI8103.exe | |
Popis |
V4.6 HW Upgrade (X67SI8103) Revision information X67SI8103 Version 2.6.0.0: ID: 780170 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780275 New data sheet V2.18 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(580) Version 2.4.0.0: ID: 715280 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727155 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(574) Version 2.3.1.0: ID: 706365 Limit values for the module cycle time adjusted The limit values for the calculation and monitoringof module cycle time andslot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706405 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(573) Version 2.2.0.0: ID: 668625 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688775 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689725 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689960 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690110 New data sheet V2.06 Forchanges see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(571) Version 2.1.0.0: ID:644315 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - seechapter "Switching to mapp Safety" in help! Channel description changed:Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\47996_1.fw(570) Version 1.10.10.0: ID: 622805 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(331) Version 1.10.9.1: ID: 643225 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.9.0: ID: 460730 / Support ID: 400173996, 400196973,400253218 functional outputs deaktivated at powerup The functional outputs are deactivated on while powerup of module now. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 618295 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.1.1: ID: 559200 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(326) Version 1.10.1.0: ID: 516625 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 533060 Add blackout mode Add blackout mode Channel description changed:Yes Configuration description changed: No Firmware changed: No ID: 533150 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 541340 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No ID: 550705 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550745 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(325) Version 1.10.0.1: ID: 487615 / Support ID: 400191602 Possibility to configure the outputs to be switched in SafeDESIGNER Startingwith SafetyRelease 1.10 the outputs can be configured to be switched in SafeDESIGNER instead of Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.10.0.0: ID: 385305 / Support ID: 400135300 keine Channel description changed: No Configuration description changed: No Firmware changed: No ID: 402845 / Support ID: 400142613 Step File The step file is available since 14th November 2014. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470675 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470680 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.9.1.0: ID: 424655 change of input filter The behaviour of the input filterhas changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424660 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 424665 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301) Version 1.9.0.0: ID: 413880 SafeModuleID>300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414035 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414375 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290), 4\47996_1.fw(300) Version 1.6.0.8: ID: 388480 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.7: ID: 339305 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.5: ID: 335525 /Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDsup to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335530 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.0: ID: 314370 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.4: ID: 303420 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.1: ID: 294350 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.4.0.0 | * | 09.06.2021 | 2 MB | EXE | AS4_HW_X67SI8103.exe | |
Popis |
V4.6 HW Upgrade (X67SI8103) Revision information X67SI8103 Version 2.4.0.0: ID: 715280 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 727155 New data sheet V2.10 For changes see chapter "Version history" in the datasheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(574) Version 2.3.1.0: ID: 706365 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706405 New data sheet V2.08 For changes see chapter "Version history"in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(573) Version 2.2.0.0: ID: 668625 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688775 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689725 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 689960 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690110 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(571) Version 2.1.0.0: ID: 644315 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\47996_1.fw(570) Version 1.10.10.0: ID: 622805 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(331) Version 1.10.9.1: ID: 643225 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.9.0: ID: 460730 / Support ID: 400173996, 400196973, 400253218 functional outputs deaktivated at powerup The functional outputs aredeactivated on while powerup of module now. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 618295 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.1.1: ID: 559200 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(326) Version 1.10.1.0: ID: 516625 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 533060 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533150 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed:No Firmware changed: No ID: 541340 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550705 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550745 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(325) Version 1.10.0.1: ID: 487615 / Support ID: 400191602 Possibility toconfigure the outputs to be switched in SafeDESIGNER Starting with SafetyRelease 1.10 the outputs can be configured to be switched in SafeDESIGNER instead of Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.10.0.0: ID: 385305 / Support ID: 400135300 keine Channel description changed: No Configuration description changed: No Firmware changed: No ID: 402845 / Support ID: 400142613 Step File The step file is available since 14th November 2014. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470675 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470680 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.9.1.0: ID: 424655 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424660 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 424665 Update Online Help Update Online Help V1.91 Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 6\47996_1.fw(301) Version 1.9.0.0: ID: 413880 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in theAS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414035 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414375 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290), 4\47996_1.fw(300) Version 1.6.0.8: ID: 388480 Themodule also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.7: ID: 339305 internalAdjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.5: ID: 335525 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335530 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.0: ID: 314370 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.4: ID: 303420 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.1: ID: 294350 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.3.1.0 | * | 01.12.2020 | 2 MB | EXE | AS4_HW_X67SI8103.exe | |
Popis |
V4.6 HW Upgrade (X67SI8103) Revision information X67SI8103 Version 2.3.1.0: ID: 706365 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706405 New data sheet V2.08 For changes see chapter "Version history" inthe data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(573) Version 2.2.0.0: ID: 668625 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688775 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even thoughthe parametrized "safe data duration"is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689725 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689960 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690110 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(571) Version 2.1.0.0: ID: 644315 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\47996_1.fw(570) Version 1.10.10.0: ID: 622805 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(331) Version 1.10.9.1: ID: 643225 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.9.0: ID: 460730 / Support ID: 400173996, 400196973, 400253218 functional outputs deaktivated at powerup The functional outputs are deactivated on while powerup of module now. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 618295 logger entry 112174, 108078 Logger entry 112174, 108078could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.1.1: ID: 559200 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(326) Version 1.10.1.0: ID: 516625 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 533060 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533150 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 541340 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550705 Loggerentry on negativ edgeof SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550745 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(325) Version 1.10.0.1: ID: 487615 / Support ID: 400191602 Possibility to configure the outputs to be switched in SafeDESIGNER Starting with SafetyRelease 1.10 the outputs can be configured to be switched in SafeDESIGNER instead of Automation Studio Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.10.0.0: ID: 385305 / Support ID: 400135300 keine Channel description changed: No Configuration description changed: No Firmware changed: No ID: 402845 / Support ID: 400142613 Step File The step file is available since 14thNovember 2014. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470675 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470680 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.9.1.0: ID: 424655 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424660 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 424665 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301) Version 1.9.0.0: ID: 413880 SafeModuleID >300 Nowit is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414035 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414375 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290), 4\47996_1.fw(300) Version 1.6.0.8: ID: 388480 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.7: ID: 339305 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:3\47996_1.fw(290) Version 1.6.0.5: ID: 335525 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335530 The modulealso supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.0: ID: 314370 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.4: ID: 303420 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:3\47996_1.fw(290) Version 1.5.0.1: ID: 294350 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.2.0.0 | * | 21.07.2020 | 2 MB | EXE | AS4_HW_X67SI8103.exe | |
Popis |
V4.6 HW Upgrade (X67SI8103) Revision information X67SI8103 Version 2.2.0.0: ID: 668625 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 688775 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689725 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 689960 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690110 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\47996_1.fw(571) Version 2.1.0.0: ID: 644315 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\47996_1.fw(570) Version 1.10.10.0: ID: 622805 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301),7\47996_1.fw(331) Version 1.10.9.1: ID: 643225 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.9.0: ID: 460730 / Support ID: 400173996, 400196973, 400253218 functionaloutputs deaktivated at powerup The functional outputs are deactivated onwhile powerup of module now. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 618295 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.1.1: ID: 559200 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(326) Version 1.10.1.0: ID: 516625 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 533060 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533150 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 541340 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550705 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 550745 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(325) Version 1.10.0.1: ID: 487615 / Support ID: 400191602 Possibility to configure the outputs to be switched in SafeDESIGNER Starting with SafetyRelease 1.10 the outputs can be configured to be switched in SafeDESIGNER instead of Automation Studio Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.10.0.0: ID: 385305 / Support ID: 400135300 keine Channel description changed: No Configuration description changed: No Firmware changed: No ID: 402845 / Support ID: 400142613 Step File The step file is available since 14th November 2014. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470675 changed manual verionto 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470680 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.9.1.0: ID: 424655 change ofinput filter The behaviour of the input filter has changed. Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 424660 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 424665 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301) Version 1.9.0.0: ID: 413880 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414035 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmwarechanged: No ID: 414375 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290), 4\47996_1.fw(300) Version 1.6.0.8: ID: 388480 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.7: ID: 339305 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.5: ID: 335525 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335530 The module also supports SafetyRelease 1.7 Starting with this version, the module also supportsSafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.0: ID: 314370 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.4: ID: 303420 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.1: ID: 294350 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.1.0.0 | * | 05.07.2019 | 1 MB | EXE | AS4_HW_X67SI8103.exe | |
Popis |
V4.6 HW Upgrade (X67SI8103) Revision information X67SI8103 Version 2.1.0.0: ID: 644315 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\47996_1.fw(570) Version 1.10.10.0: ID: 622805 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(331) Version 1.10.9.1: ID: 643225 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.9.0: ID: 460730 / Support ID: 400173996, 400196973, 400253218 functional outputs deaktivated at powerup The functional outputs are deactivated on while powerup of module now. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 618295 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(330) Version 1.10.1.1: ID: 559200 minimum allowed operating temperature extended to -40°C The minimum allowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(326) Version 1.10.1.0: ID: 516625 minimum allowed operating temperature extended to -40°C The minimumallowed operating temperature was extended to -40°C Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 533060 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533150 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID:541340 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 550705 Loggerentry on negativ edge of SafeModuleOK If a negativ edgeon SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 550745 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configurationdescription changed: No Firmware changed: Yes Firmware: 6\47996_1.fw(301), 7\47996_1.fw(325) Version 1.10.0.1: ID: 487615 / Support ID: 400191602 Possibility to configure the outputs to be switched in SafeDESIGNER Starting with SafetyRelease 1.10 the outputs can be configured to be switched in SafeDESIGNER instead of Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version1.10.0.0: ID: 385305 / Support ID: 400135300 keine Channeldescription changed: No Configuration description changed: No Firmware changed: No ID: 402845 / Support ID: 400142613 Step File The step file is available since 14th November 2014. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470675 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 470680 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 6\47996_1.fw(301), 7\47996_1.fw(320) Version 1.9.1.0: ID: 424655 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424660 fw valid from SafetyRelease 1.2 on The firmware is used for all SafetyReleases from 1.2 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 424665 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 6\47996_1.fw(301) Version 1.9.0.0: ID:413880 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414035 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414375 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290), 4\47996_1.fw(300) Version 1.6.0.8: ID: 388480 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.7: ID: 339305 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.5: ID: 335525 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 335530 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.6.0.0: ID: 314370 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.4: ID: 303420 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\47996_1.fw(290) Version 1.5.0.1: ID: 294350 First Official Release First Official Release Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 3\47996_1.fw(290) |