Popis |
V4.6 HW Upgrade (X20SI8110) Revision information X20SI8110 Version 2.6.0.0: ID: 780340 New data sheet V2.20 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 780355 Correction of the input filter with set "Filter off". Correction of the input filter, if a "Filter off" is set and a channel error is detected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 780400 / Support ID: 400412437 Configuration for Power Calculation available The Configuration for Power Calculation is now available in Automation Studio Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 10\59202_1.fw(580) Version 2.4.0.0: ID: 719745 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 726610 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID:727130 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(574) Version 2.3.1.0: ID: 706330 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706390 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(573) Version 2.3.0.0: ID: 692365 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692395 / Support ID: 400311305 The OSDD signal at the pulse output is corrected. The OSDD signal atthe pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696565 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(572) Version 2.2.0.0: ID: 668560 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID:689935 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690080 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 690165 Propagation delay statistics The Propagation delay statistics can now be readout. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690170 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\59202_1.fw(571) Version 2.1.0.0: ID: 644310 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must beadapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\59202_1.fw(570) Version 1.10.9.1: ID: 643470 data sheet V1.141 See chapture "Version history" in thedata sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(330) Version 1.10.9.0: ID: 618230 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59202_1.fw(330) Version 1.10.1.0: ID: 575525 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configurationdescription changed: No Firmware changed: Yes ID: 575530 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 575535 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 575540 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 577395 / Support ID: 400234330 Increasethe tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(325) Version 1.10.0.6: ID: 533070 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 543080 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543085 New channel for ConnectionValid New channel forConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(322) Version 1.10.0.3: ID: 463885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59202_1.fw(322) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.4.0.0 | * | 09.06.2021 | 1 MB | EXE | AS4_HW_X20SI8110.exe | |
Popis |
V4.6 HW Upgrade (X20SI8110) Revision information X20SI8110 Version 2.4.0.0: ID: 719745 Failsafe at every boot It could happen under rare conditions that the module is stuck in failsafe state at every boot, generating logger messages: -1073565951/-1073561855 "internal cross communication error EPS" or -1073565945/-1073561849 "Received crc data is not equal to sent crc data" Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 726610 The power calculation of the modules is supported The data for the power calculation of the data sheet is included in the HWX. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 727130 New data sheet V2.10 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(574) Version 2.3.1.0: ID: 706330 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706390 New data sheet V2.08 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(573) Version 2.3.0.0: ID: 692365 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692395 / SupportID: 400311305 The OSDD signal at the pulse output is corrected. TheOSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696565 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(572) Version 2.2.0.0: ID: 668560 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689935 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690080 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 690165 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690170 / Support ID: 400299371 Loss of safety connection Loss of safety connection,even though the parametrized "safe data duration"is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\59202_1.fw(571) Version 2.1.0.0: ID: 644310 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\59202_1.fw(570) Version 1.10.9.1: ID: 643470 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(330) Version 1.10.9.0: ID: 618230 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59202_1.fw(330) Version 1.10.1.0: ID: 575525 add PhysicalStateChannels on X20SLX842 addPhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 575530 Adapt filter algorithm to eliminate dependencies between TON andTOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 575535 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 575540 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 577395 / Support ID: 400234330 Increase the tolerance of the voltage monitor The tolerance of thevoltage monitor was increased to prevent sporadic falseerrors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(325) Version 1.10.0.6: ID: 533070 Add blackout mode Add blackout mode Channeldescription changed: Yes Configuration description changed: No Firmware changed: No ID: 543080 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543085 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(322) Version 1.10.0.3: ID: 463885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59202_1.fw(322) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.3.1.0 | * | 01.12.2020 | 1 MB | EXE | AS4_HW_X20SI8110.exe | |
Popis |
V4.6 HW Upgrade (X20SI8110) Revision information X20SI8110 Version 2.3.1.0: ID: 706330 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 706390 New data sheet V2.08 For changes see chapter "Version history" inthe data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(573) Version 2.3.0.0: ID: 692365 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 692395 / Support ID: 400311305 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse outputis output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696565 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(572) Version 2.2.0.0: ID: 668560 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689935 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690080 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 690165 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690170 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 10\59202_1.fw(571) Version 2.1.0.0: ID: 644310 major (even incompatible) changes for mapp Safety First upgradefor mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\59202_1.fw(570) Version 1.10.9.1: ID: 643470 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(330) Version 1.10.9.0: ID:618230 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59202_1.fw(330) Version 1.10.1.0: ID: 575525 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 575530 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 575535 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 575540 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed:No ID: 577395 / Support ID: 400234330 Increase the tolerance ofthe voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(325) Version 1.10.0.6: ID: 533070 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 543080 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543085 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(322) Version 1.10.0.3: ID: 463885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59202_1.fw(322) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.3.0.0 | * | 02.09.2020 | 1 MB | EXE | AS4_HW_X20SI8110.exe | |
Popis |
V4.6 HW Upgrade (X20SI8110) Revision information X20SI8110 Version 2.3.0.0: ID: 692365 Support of the DYNlink interface The DYNlink interface is supported by the safe inputs. Channel description changed: No Configuration description changed: Yes Firmware changed:Yes ID: 692395 / Support ID: 400311305 The OSDD signal at the pulse output is corrected. The OSDD signal at the pulse output is output correctly even when not in use. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 696565 New data sheet V2.07 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 10\59202_1.fw(572) Version 2.2.0.0: ID: 668560 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689935 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690080 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 690165 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690170 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\59202_1.fw(571) Version 2.1.0.0: ID: 644310 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\59202_1.fw(570) Version 1.10.9.1: ID: 643470 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(330) Version 1.10.9.0: ID: 618230 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59202_1.fw(330) Version 1.10.1.0: ID: 575525 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 575530 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 575535 Provide CRC of theFirmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 575540 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 577395 / Support ID: 400234330 Increase the tolerance of the voltagemonitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(325) Version 1.10.0.6: ID: 533070 Add blackout mode Add blackout mode Channel description changed: Yes Configurationdescription changed: No Firmware changed: No ID: 543080 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543085 Newchannel for ConnectionValid New channel for ConnectionValid Channeldescription changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(322) Version 1.10.0.3: ID: 463885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59202_1.fw(322) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.2.0.0 | * | 21.07.2020 | 1 MB | EXE | AS4_HW_X20SI8110.exe | |
Popis |
V4.6 HW Upgrade (X20SI8110) Revision information X20SI8110 Version 2.2.0.0: ID: 668560 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689935 Improvement of the internalvoltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690080 New data sheet V2.06 For changes see chapter "Version history" in the data sheet. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 690165 Propagation delay statistics The Propagation delay statistics can now be read out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 690170 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 10\59202_1.fw(571) Version 2.1.0.0: ID: 644310 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\59202_1.fw(570) Version 1.10.9.1: ID: 643470 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(330) Version 1.10.9.0: ID: 618230 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59202_1.fw(330) Version 1.10.1.0: ID: 575525 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 575530 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 575535 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 575540 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 577395/ Support ID: 400234330 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(325) Version 1.10.0.6: ID: 533070 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 543080 New default values The default values for "Filter On" and "Discrepancy Time" have beenmodified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543085 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(322) Version 1.10.0.3: ID: 463885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59202_1.fw(322) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.1.0.0 | * | 05.07.2019 | 1 MB | EXE | AS4_HW_X20SI8110.exe | |
Popis |
V4.6 HW Upgrade (X20SI8110) Revision information X20SI8110 Version 2.1.0.0: ID: 644310 major (even incompatible) changes for mapp Safety First upgrade for mapp Safety. ATTENTION: existing applications must be adapted - see chapter "Switching to mapp Safety" in help! Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 10\59202_1.fw(570) Version 1.10.9.1: ID: 643470 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(330) Version 1.10.9.0: ID: 618230 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59202_1.fw(330) Version 1.10.1.0: ID: 575525 add PhysicalStateChannels on X20SLX842 add PhysicalStateChannels on X20SLX842. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 575530 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 575535 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: No ID: 575540 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 577395 / Support ID: 400234330 Increase the tolerance of the voltage monitor The tolerance of the voltage monitor was increased to prevent sporadic false errors 99849 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(325) Version 1.10.0.6: ID: 533070 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmwarechanged: No ID: 543080 New default values The default values for "Filter On" and "Discrepancy Time" have been modified Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543085 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\59202_1.fw(322) Version 1.10.0.3: ID: 463885 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\59202_1.fw(322) |