DWL@DWL10000679245
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.4.0.1 | * | 20.07.2023 | 576 KB | EXE | AS4_HW_8EIxxxHxSSx.xxxx-1.exe | |
Popis |
V4.4 HW Upgrade (8EIxxxHxSSx.xxxx-1) Revision information 8EIxxxHxSSx.xxxx-1 Version 2.4.0.1: ID: 727230 / Support ID: 400353504 Wrong description for encoder connector in module configuration For some modules the description of the encoder connector was wrong. The description of the encoder connector in the configuration in AS was not the same as on the housing of the module. Added attribute "Label" for encoder connectors. -Automation Studio version AS 4.4.4 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 758995 HW upgrade for support of ACOPOS P3 modules without rectifier New ACP P3 servo drives 8EI017HCDS2.xxxx-1 and 8EI022HCDS2.xxxx-1 without rectifier are now supported. -Automation Studio version 4.4.4 -mapp Motion version 5.18.0 -ACP10 version: no restriction Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.4.0.0: ID: 712440 ACOPOS P3 SafeMOTION: Safe encoder interface "HIPERFACE DSL SafeMOTION" supported The safe encoder interface "HIPERFACE DSL SafeMOTION" is now supported for ACOPOS P3 SafeMOTION modules. -ACP10 version 5.13.0 -mappMotion version 5.13 -Automation Studio minimum version AS 4.4.4 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.3.1.2: ID: 707135 / Support ID: 400193653, 400199515, 400216656, 400240315, 400244641, 400259325, 400259805, 400264294, 400264504, 400267855, 400276023, 400282533, 400286540, 400293220, 400292633, 400307303, 400307335, 400318959, 400325019, 400330060 Support of Speed Torque Chart in Automation Studio for ACOPOS P3 Extension of the hardware upgrades to support the Speed Torque Chart for ACOPOS P3. This function is supported from AS 4.10. The following upgrades don´t support the Speed Torque Chart 8EIxxxHxDSx.xxxx-1 8EIxxxHxSSx.xxxx-1 8EIxxxHxTSx.xxxx-1 8EIxxxMxDSx.xxxx-1 8EIxxxMxSSx.xxxx-1 8EIxxxMxTSx.xxxx-1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.3.0.3: ID: 653460 Support of T-Format (Tamagawa) encoder added -ACP10 version 5.08.0 -mapp Motion version 5.8.0 -Automation Studio version AS 4.0.11 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 683195 Added description "(PLK)" for attribute "Label" for Powerlink connectors Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.3.0.2: ID: 622560 Parameter "SdcEnabled" initialized incorrectly Data type of parameter was changed to STRING and inital value to "off". Channel description changed: No Configuration description changed: No Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.4.0.0 | * | 04.03.2021 | 256 KB | EXE | AS4_HW_8EIxxxHxSSx.xxxx-1.exe | |
Popis |
V4.4 HW Upgrade (8EIxxxHxSSx.xxxx-1) Revision information 8EIxxxHxSSx.xxxx-1.xxxx-1 Version 2.4.0.0: ID: 712440 ACOPOS P3 SafeMOTION: Safe encoder interface "HIPERFACE DSL SafeMOTION" supported The safe encoder interface "HIPERFACE DSL SafeMOTION" is now supported for ACOPOS P3SafeMOTION modules. -ACP10 version 5.13.0 -mappMotion version 5.13 -Automation Studio minimum version AS 4.4.4 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.3.1.2: ID: 707135 / Support ID: 400193653, 400199515, 400216656, 400240315, 400244641, 400259325, 400259805, 400264294, 400264504, 400267855, 400276023, 400282533, 400286540, 400293220, 400292633, 400307303, 400307335, 400318959, 400325019, 400330060 Support of Speed Torque Chart in Automation Studio for ACOPOS P3 Extension of the hardware upgrades to support the Speed Torque Chart for ACOPOS P3. This function is supported from AS 4.10. The following upgrades don´t support the Speed Torque Chart 8EIxxxHxDSx.xxxx-1 8EIxxxHxSSx.xxxx-1 8EIxxxHxTSx.xxxx-1 8EIxxxMxDSx.xxxx-1 8EIxxxMxSSx.xxxx-1 8EIxxxMxTSx.xxxx-1 Channel description changed:No Configuration description changed: Yes Firmware changed: No Version 2.3.0.3: ID: 653460 Support of T-Format (Tamagawa) encoder added -ACP10 version 5.08.0 -mapp Motion version 5.8.0 -Automation Studio version AS 4.0.11 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 683195 Added description "(PLK)" for attribute "Label" for Powerlink connectors Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.3.0.2: ID: 622560 Parameter "SdcEnabled" initialized incorrectly Data type of parameter was changed to STRING and inital value to "off". Channel description changed: No Configuration description changed: No Firmware changed: No |