1.15.0.0 | * | 20.07.2023 | 5 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT Version 1.15.0.0: ID: 772635 / Support ID: 400400350, 400406359, 400407650 Wrong power consumption data corrected: calculated values in ASdid not match to correct documentation Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(17), 1\59143a0.epl(142) Version 1.14.0.0: ID: 736775 Fixed boot and warm restart issue In rare cases the X20CP13xx does not boot correctly after a restart Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(17), 1\59143a0.epl(142) Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel descriptionchanged: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 704885 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface couldfail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(142) Version 1.11.1.0: ID: 664935 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 695220 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.11.0.0: ID: 673090 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673140 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.10.0.0: ID: 652305 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652400 Error correction: DNA tree topologies not always started up correctly Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 669160 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 672490 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(141) Version 1.8.0.0: ID: 636550 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 636785 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(138) Version 1.7.0.0: ID: 610705 / Support ID: 400250890 POWERLINKCNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.14.0.0 | * | 24.09.2021 | 5 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT-RT Version 1.14.0.0: ID: 736775 Fixed boot and warm restart issue In rare cases the X20CP13xx does not boot correctly after a restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(17), 1\59143a0.epl(142) Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 704885 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK networkin this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(142) Version 1.11.1.0: ID: 664935 Support data point StorageWear, wear level of storage mediumstarting from AR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 695220 Support for automatic DNA configuration from AS 4.9.1 Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.11.0.0: ID: 673090 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the lossof the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673140 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.10.0.0: ID: 652305 POWERLINK: Possible failure of already configuredCNs if new "chained stations" added during operation Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 652400 Error correction: DNA tree topologies not alwaysstarted up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669160 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 672490 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(141) Version 1.8.0.0: ID: 636550 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 636785 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(138) Version 1.7.0.0: ID: 610705 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINKV2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames weresent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.13.0.0 | * | 23.07.2021 | 4 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT-RT Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 704885 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(142) Version 1.11.1.0: ID: 664935 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 695220 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.11.0.0: ID: 673090 Additional status bit for rtiABRPos reference impulseloss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673140 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.10.0.0: ID: 652305 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652400 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669160 Module documentation revised Data sheet V 1.23 Channel description changed:No Configuration description changed: No Firmware changed: No ID: 672490 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(141) Version 1.8.0.0: ID: 636550 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 636785 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(138) Version 1.7.0.0: ID: 610705 / SupportID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentationrevised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timingproblem in the firmware it could happen that no asynchronous frames were sentin the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.12.0.0 | * | 08.04.2021 | 4 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT-RT Version 1.12.0.0: ID: 704885 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(142) Version 1.11.1.0: ID: 664935 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 695220 Support for automatic DNA configurationfrom AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.11.0.0: ID: 673090 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673140 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.10.0.0: ID: 652305 POWERLINK:Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652400 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669160 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 672490 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware:1\59143_0.pci(13), 1\59143a0.epl(141) Version 1.8.0.0: ID: 636550 POWERLINK-Manager: With frequent failure of CN's, which are operatedwith the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 636785 Module documentation revised Data sheet V 1.21 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(138) Version 1.7.0.0: ID: 610705 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flagsof CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225/ Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.11.0.0 | * | 28.01.2020 | 4 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT Version 1.11.0.0: ID: 673090 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, thatdetects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673140 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(14), 1\59143a0.epl(141) Version 1.10.0.0: ID: 652305 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652400 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669160 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 672490 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(141) Version 1.8.0.0: ID: 636550 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization"Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 636785 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(138) Version 1.7.0.0: ID: 610705 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be receivedfrom all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.0.0 | * | 11.12.2019 | 4 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT Version 1.10.0.0: ID: 652305 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652400 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669160 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 672490 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(141) Version 1.8.0.0: ID: 636550 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressedby the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 636785 Module documentation revised Data sheet V 1.21 Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(138) Version 1.7.0.0: ID: 610705 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTsoutputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacingthe CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.8.0.0 | * | 21.05.2019 | 4 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT Version 1.8.0.0: ID: 636550 POWERLINK-Manager: With frequentfailure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 636785 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(13), 1\59143a0.epl(138) Version 1.7.0.0: ID: 610705 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.7.0.0 | * | 06.09.2018 | 4 MB | EXE | AS4_HW_X20cCP1382-RT.exe | |
Popis |
V4.2 HW Upgrade (X20cCP1382-RT) Revision information X20cCP1382-RT Version 1.7.0.0: ID: 610705 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610715 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(12), 1\59143a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID:543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |