DWL@DWL10000349443

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.7.0.0 * 23.07.2021 3 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.7.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.6.1.0:

ID: 687470
Limitation of the cycle time
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 689455
Module documentation revised
Data sheet V 1.25
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430)

Version 1.6.0.0:

ID: 650580
Additional status bit for rtiABRPos reference impulse loss
An additional status bit was introduced, that detects the loss of the reference impulse signals.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430)

Version 1.5.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: 623545
Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8001
Bootup time has been improved
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.1.0:

ID:601825
Correction HWX-File
Parameter specification corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.0.0:

ID: 594335
Support new hwvariante 4 with fw v420
Solving bootup problems
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 594890
Added configuration "blackout mode"
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600635
Module documentation revised
Data sheet V 1.23
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID:463510
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.6.1.0 * 10.06.2020 3 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.6.1.0:

ID: 687470
Limitation of the cycle time
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 689455
Module documentation revised
Data sheet V 1.25
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430)

Version 1.6.0.0:

ID: 650580
Additional status bit for rtiABRPos reference impulse loss
An additional status bit was introduced, that detects the loss of the reference impulse signals.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430)

Version 1.5.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: 623545
Bootup time significantly increases withupgrade V1.3.0.0 of X20RT8001
Bootup time has been improved
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.1.0:

ID: 601825
Correction HWX-File
Parameter specification corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.0.0:

ID: 594335
Support new hw variante 4 with fw v420
Solving bootup problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 594890
Added configuration "blackout mode"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600635
Module documentation revised
Data sheet V 1.23
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed:Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentationrevised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.6.0.0 * 16.01.2020 3 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.6.0.0:

ID: 650580
Additional status bit for rtiABRPos reference impulse loss
An additional status bit was introduced, that detects the loss of the reference impulse signals.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(430), 1\58713_3.fw(430), 1\58713_4.fw(430)

Version 1.5.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: 623545
Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8001
Bootup time has been improved
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.1.0:

ID: 601825
Correction HWX-File
Parameter specification corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.0.0:

ID: 594335
Support new hw variante 4 with fw v420
Solving bootup problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 594890
Added configuration "blackout mode"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600635
Module documentation revised
Data sheet V 1.23
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputscorrected
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200),1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.5.0.0 * 25.10.2019 3 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.5.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID: 623545
Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8001
Bootup time has been improved
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.1.0:

ID: 601825
Correction HWX-File
Parameter specification corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.0.0:

ID: 594335
Support new hw variante 4 with fw v420
Solving bootup problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 594890
Added configuration "blackout mode"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600635
Module documentation revised
Data sheet V 1.23
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as firstinstruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support forAutomation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.4.0.0 * 18.12.2018 3 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.4.0.0:

ID: 623545
Bootup time significantly increases withupgrade V1.3.0.0 of X20RT8001
Bootup time has been improved
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.1.0:

ID: 601825
Correction HWX-File
Parameter specification corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.0.0:

ID: 594335
Support new hw variante 4 with fw v420
Solving bootup problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 594890
Added configuration "blackout mode"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600635
Module documentation revised
Data sheet V 1.23
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed:Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentationrevised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.3.1.0 * 10.08.2018 3 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.3.1.0:

ID: 601825
Correction HWX-File
Parameter specification corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.3.0.0:

ID: 594335
Support new hw variante 4 with fw v420
Solving bootup problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 594890
Added configuration "blackout mode"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600635
Module documentation revised
Data sheet V 1.23
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Datasheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonizationof all reACTION modules
Harmonization of hardwarefiles for similar usageand easier maintenance.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.3.0.0 * 28.06.2018 3 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.3.0.0:

ID: 594335
Support new hw variante 4 with fw v420
Solving bootup problems
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 594890
Added configuration "blackout mode"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600635
Module documentation revised
Data sheet V 1.23
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420), 1\58713_4.fw(420)

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed:Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.2.0.0 * 24.04.2018 2 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.2.0.0:

ID: 587355 / Support ID: 400247572
Correction of the functionality of the timestamp outputs
Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 591710
Module documentation revised
Data sheet V 1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(420), 1\58713_3.fw(420)

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.1.1.0 * 02.05.2017 2 MB EXE AS4_HW_X20RT8001.exe
Popis V4.1 HW Upgrade (X20RT8001)

Revision information X20RT8001

Version 1.1.1.0:

ID: 530765
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.1.0.0:

ID: 471685
Harmonization of all reACTION modules
Harmonization of hardwarefiles for similar usage and easier maintenance.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 478590
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 483495
Execution of functionblocks rtiPWM und rtiDiv revised.
The functions blocks rtiPWM and rtiDiv do not cause a timing error, when they are used as first instruction in the in reACTION task.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\58713_2.fw(320), 1\58713_3.fw(320)

Version 1.0.1.0:

ID: 463510
Module documentation revised
Data sheet V 1.04
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 469860
Correction Channel-Description
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200),1\58713_3.fw(200)

Version 1.0.0.0:

ID: 426115
Support X20RT8001
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\58713_2.fw(200), 1\58713_3.fw(200)