DWL@DWL10000455795
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.10.0.0 | * | 20.07.2023 | 4 MB | EXE | AS4_HW_X20cCP1301.exe | |
Popis |
V4.1 HW Upgrade (X20cCP1301) Revision information X20cCP1301 Version 1.10.0.0: ID: 772630 / Support ID: 400400350, 400406359, 400407650 Wrong power consumption data corrected: calculated values in AS did not match to correct documentation Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\60248_0.pci(17) Version 1.9.0.0: ID: 736770 Fixed boot and warm restart issue In rare cases the X20CP13xx does not boot correctly after a restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60248_0.pci(17) Version 1.8.0.0: ID: Adaptations for Automation Studio4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.7.0.0: ID: 673160 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60248_0.pci(16) Version 1.6.1.0: ID: 547425 Module documentation revised Data sheet V1.16 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 568505 / Support ID: 400237284 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.5.0.0: ID: 537190 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 537205 X20(c)CP13xx module documentation revised Data sheet V 1.15 Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.3.2.0: ID: 490200 Support X20cCP1301 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60248_0.pci(13) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.9.0.0 | * | 24.09.2021 | 4 MB | EXE | AS4_HW_X20cCP1301.exe | |
Popis |
V4.1 HW Upgrade (X20cCP1301) Revision information X20cCP1301 Version 1.9.0.0: ID: 736770 Fixed boot and warm restart issue In rare cases the X20CP13xx does not boot correctly after a restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60248_0.pci(17) Version 1.8.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.7.0.0: ID: 673160 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60248_0.pci(16) Version 1.6.1.0: ID: 547425 Module documentation revised Data sheet V1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 568505 / Support ID: 400237284 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.5.0.0: ID: 537190 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 537205 X20(c)CP13xx module documentation revised Data sheet V 1.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.3.2.0: ID: 490200 Support X20cCP1301 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60248_0.pci(13) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.8.0.0 | * | 23.07.2021 | 3 MB | EXE | AS4_HW_X20cCP1301.exe | |
Popis |
V4.1 HW Upgrade (X20cCP1301) Revision information X20cCP1301 Version 1.8.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.7.0.0: ID: 673160 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60248_0.pci(16) Version 1.6.1.0: ID: 547425 Module documentation revised Data sheet V1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 568505 / Support ID: 400237284 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.5.0.0: ID: 537190 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 537205 X20(c)CP13xx module documentation revised Data sheet V 1.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.3.2.0: ID: 490200 Support X20cCP1301 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60248_0.pci(13) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.7.0.0 | * | 28.01.2020 | 4 MB | EXE | AS4_HW_X20cCP1301.exe | |
Popis |
V4.1 HW Upgrade (X20cCP1301) Revision information X20cCP1301 Version 1.7.0.0: ID: 673160 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\60248_0.pci(16) Version 1.6.1.0: ID: 547425 Module documentation revised Data sheet V1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 568505 / Support ID: 400237284 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.5.0.0: ID: 537190 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 537205 X20(c)CP13xx module documentation revised Data sheet V 1.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.3.2.0: ID: 490200 Support X20cCP1301 Channel description changed: Yes Configuration description changed: Yes Firmware changed:Yes Firmware: 1\60248_0.pci(13) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.6.1.0 | * | 07.12.2017 | 4 MB | EXE | AS4_HW_X20cCP1301.exe | |
Popis |
V4.1 HW Upgrade (X20cCP1301) Revision information X20cCP1301 Version 1.6.1.0: ID: 547425 Module documentation revised Datasheet V1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 568505 / Support ID: 400237284 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.5.0.0: ID: 537190 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 537205 X20(c)CP13xx module documentation revised Data sheet V 1.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\60248_0.pci(13) Version 1.3.2.0: ID: 490200 Support X20cCP1301 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\60248_0.pci(13) |