DWL@DWL10000326476
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.0.1.0 | * | 10.06.2022 | 238 KB | EXE | AS4_HW_5ACCLI01.SDL0-000.exe | |
Popis |
V4.1 HW Upgrade (5ACCLI01.SDL0-000) Revision information 5ACCLI01.SDL0-000 Version 2.0.1.0: ID: 751445 / Support ID: 400380204 Bugfix: Module supervision of the APC2100/APC2200 Monitor/Panel option fromARA4.81. Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 2.0.0.0: ID: 667070 Extensions Hypervisor from AR A4.81 USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver,SDLx Transmitter). Starting with AS 4.8 following HWX upgrades (or newer) are recommended for APC2100/APC2200, mixed operation of the current and older HWX upgrades is not recommended: APC2100 system unit: V2.1.0.0 APC2200 system unit: V2.0.0.0 5ACCLI01.SDL0-000: V2.0.0.0 AP1000 panels: V2.0.0.0 AP9x3 panels: V2.0.0.0 AP9xD panels: V2.0.0.0 AP900 panels: V2.0.0.0 AP5000 panels: V2.0.0.0 AP5000 extension unit: V2.0.0.0 5DLSDL.1001-00: V2.0.0.0 5DLSDL.1002-00: V2.0.0.0 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 667075 EPLAN Daten implemented Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 677900 Module supervision of the APC2100/APC2200 Monitor/Panel option from AR A4.81: The supervision of the APC2100/APC2200 Monitor/Panel option is activ from Automation Runtime version A4.81. In case of a missconfiguration or missing APC2100/APC2200 Monitor/Panel option the Automation PC is starting up in the service mode. This behavior can be configured via the configuration of the supervised option, the default is supervised = on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 681980 Support for IOMapping starting with AS 4.8.2/AR A4.82. Channel description changed: Yes Configuration description changed: No Firmware changed: No Version 1.1.0.0: ID: 647700 Preparation to support the Automation PC 2200 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.0.0.0: ID: 407610 First official version Channel description changed: Yes Configuration description changed: Yes Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.0.0.0 | * | 08.04.2020 | 235 KB | EXE | AS4_HW_5ACCLI01.SDL0-000.exe | |
Popis |
V4.1 HW Upgrade (5ACCLI01.SDL0-000) Revision information 5ACCLI01.SDL0-000 Version 2.0.0.0: ID: 667070 Extensions Hypervisor from AR A4.81 USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter). Starting with AS 4.8 following HWX upgrades (or newer) are recommended for APC2100/APC2200, mixed operation of the current and older HWX upgrades is not recommended: APC2100 system unit: V2.1.0.0 APC2200 system unit: V2.0.0.0 5ACCLI01.SDL0-000: V2.0.0.0 AP1000 panels: V2.0.0.0 AP9x3 panels: V2.0.0.0 AP9xD panels: V2.0.0.0 AP900 panels: V2.0.0.0 AP5000 panels: V2.0.0.0 AP5000 extension unit: V2.0.0.0 5DLSDL.1001-00: V2.0.0.0 5DLSDL.1002-00: V2.0.0.0 Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 667075 EPLAN Daten implemented Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 677900 Module supervision of the APC2100/APC2200 Monitor/Panel option from AR A4.81: The supervision of the APC2100/APC2200 Monitor/Panel option is activ from Automation Runtime version A4.81. In case of a missconfiguration or missing APC2100/APC2200 Monitor/Panel option the Automation PC is starting up in the service mode. This behavior can be configured via the configuration of the supervised option, the default is supervised = on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 681980 Support for IOMapping starting with AS 4.8.2/AR A4.82. Channel description changed: Yes Configuration description changed: No Firmware changed: No Version 1.1.0.0: ID: 647700 Preparation to support the AutomationPC 2200 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.0.0.0: ID: 407610 First official version Channel description changed: Yes Configuration description changed: Yes Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.0.0.0 | * | 27.01.2015 | 357 KB | EXE | AS4_HW_5ACCLI01.SDL0-000.exe | |
Popis |
V4.1 HW Upgrade (5ACCLI01.SDL0-000) Revision information 5ACCLI01.SDL0-000 Version 1.0.0.0: ID: 407610 First official version Channel description changed: Yes Configuration description changed: Yes Firmware changed: No |