DWL@DWL10000303185
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.10.9.0 | * | 08.11.2018 | 6 MB | EXE | AS4_HW_X20SLX210.exe | |
Popis |
V4.0 HW Upgrade (X20SLX210) Revision information X20cSLX410 Version 1.10.9.0: ID: 618245 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(330) Version 1.10.5.0: ID: 582825 logger message 106773 Fix for logger message 106773 "Parameter checksum sizes do not match". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(326) Version 1.10.4.1: ID: 585670 channel error when wired to +24V Temporary channel errors (logger entry 115011) are reported if If channels arewired to +24V during module bootup. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:589970 additional parameters Support additonal parameters (AsSafetyFBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41! Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589975 fix CLEAR DATA Not all relevant data has been deleted upon command "CLEAR DATA" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589980 logger entry 123432 fixed logger entry 123432 when using setup mode in combination with machineoptions Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589985 bootup time increase of bootup time with Upgrade V1.10.2.9 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589990 increased tolerance against asynchronous communication problems Problems in asynchronous communication to safety modules now cause the modulesto be rated as "missing" not until the "Node Guarding Timeout" has expired (instead of after a few seconds) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589995 extended operating temperature range Firmware preparation for hardware revisions that allow operating temperature range down to -40°C. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(326) Version 1.10.3.2: ID: 549110 / Support ID: 400225917 Correctionof SLX download frame Correction of SLX download frame Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.3.1: ID: 537600 logger message 110367 with external maschine options SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message 110367 and others). Channel description changed: No Configuration description changed: No Firmware changed: No ID: 537605 logger message 123416 when aknowledging a firmware mismatch The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.2.9: ID: 381670 / Support ID: 400132230 X20(c)SLX910: warn about invalid two channel processing mode X20(c)SLX910: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 481780 / Support ID: 400199480 error message about incompatible AR version Error message during AutomationStudio compile when trying to use Safety Release 1.10 with an AR version that is too old. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 494085 Improve SLX cycle time Performance optimization for improvement of internal SLX cycle time. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 494095 online help V1.103 Update online help to V1.103 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 502230 support Acopos P3 (X20SLX210 and X20SLX410 only) X20SLX210 and X20SLX410 support all variants of Acopos P3 (X20SLX910 supports 1 axis only) Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 513925 / Support ID: 400193973, 400206803 SLXbootState 54 SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 516045 fixes for parameters in SafeDESIGNER Minor text corrections. Remove obsolete parameter "Cycle time". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 521125 Adapt filter algorithm to eliminatedependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522940 Error while downloadingbig SafeDESIGNER applications to the SLX. Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522945 Setup Mode and automated acknowledgements - Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher) - new parameters for automated acknowledgement of SafeKEY and firmware exchange. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 528960 SafeOS Status in SafeDESIGNER Remote Control It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions. SafeDESIGNER SafePLC window or AsSafety can be used instead. This affects a set of following versions: SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3 and AR B4.26 to C4.26 or C4.33 to E4.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.0.0: ID: 374990/ Support ID: 400129134 SafeDESIGNER communication Variable status Frequent activating/deactivating of SafeDESIGNER variable status could leadtofailure of SLX communication. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 390095 / Support ID: 400137073 informations about actual application CRC and timestamp of the SafeDESIGNER application that is actually stored on the SLX can be read via asynchronous data points. Channel description changed:Yes Configuration description changed: No Firmware changed: Yes ID: 411790 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 426855 / Support ID: 400151377 Optional modules no longer reported missing via SLX LEDs Channel description changed: No Configuration description changed: No Firmware changed: No ID: 440400 / Support ID: 400147709, 400160605, 400165854, 400175456 Input checksum data error In rare cases itcould happen sporadically that the SLX entered failsafe state with "Input checksum data error" (logger messages 69648, 73744, 69655 und 73751) Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 448715 application download Performance optimization of application download to SLX. Some sequences have been changes for this which omitted some of the values ofSLXbootState. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448980 / Support ID: 400162839, 400168358 limit of max 1 SLX per CPU / line integration If there are more then one SLXin the AS hardware tree, only one of them maybe enabled. On the other hand now it is allowed to download a SafeDESIGNER application that doesn't match the SafeLOGIC-ID of the AS hardware tree. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(320) Version 1.9.2.0: ID: 450785 / Support ID: 400137924 SafeLOGIC-X with Panal PC SafeLOGIC-X didn't work with some Panal PCs (e.g. 5PC901 and 5PPC2100) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313) Version 1.9.1.0: ID: 425385 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425390 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 425395 fw valid from SafetyRelease 1.8 on The firmware is used for all SafetyReleases from 1.8 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425400 Default values changed Default values of Cycle_Time_typical_us and Default_Max_X2X_CycleTime_us changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 4\57992_1.fw(313) Version 1.9.0.0: ID: 419950 The module also supports SafetyRelease 1.9 Starting with this version, the module also supports SafetyRelease 1.9 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 419955 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 2\57992_1.fw(311) Version 1.8.0.3: ID: 393855 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 2\57992_1.fw(311) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.4.1 | * | 28.06.2018 | 5 MB | EXE | AS4_HW_X20SLX210.exe | |
Popis |
V4.0 HW Upgrade (X20SLX210) Revision information X20cSLX410 Version 1.10.4.1: ID: 585670 channel error when wired to +24V Temporary channel errors (logger entry 115011) are reported if If channels arewired to +24V during module bootup. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:589970 additional parameters Support additonal parameters (AsSafetyFBK safeDownloadData_V2.Type=safeDATA_TYPE_ADDPARA); requires AR >= A04.41! Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589975 fix CLEAR DATA Not all relevant data has been deleted upon command "CLEAR DATA" Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589980 logger entry 123432 fixed logger entry 123432 when using setup mode in combination with machineoptions Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589985 bootup time increase of bootup time with Upgrade V1.10.2.9 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589990 increased tolerance against asynchronous communication problems Problems in asynchronous communication to safety modules now cause the modulesto be rated as "missing" not until the "Node Guarding Timeout" has expired (instead of after a few seconds) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 589995 extended operating temperature range Firmware preparation for hardware revisions that allow operating temperature range down to -40°C. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(326) Version 1.10.3.2: ID: 549110 / Support ID: 400225917 Correctionof SLX download frame Correction of SLX download frame Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.3.1: ID: 537600 logger message 110367 with external maschine options SLX did not boot correctly when using external machine options with upgradeV1.10.2.9 (logger message 110367 and others). Channel description changed: No Configuration description changed: No Firmware changed: No ID: 537605 logger message 123416 when aknowledging a firmware mismatch The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with logger message 123416. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.2.9: ID: 381670 / Support ID: 400132230 X20(c)SLX910: warn about invalid two channel processing mode X20(c)SLX910: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 481780 / Support ID: 400199480 error message about incompatible AR version Error message during AutomationStudio compile when trying to use Safety Release 1.10 with an AR version that is too old. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 494085 Improve SLX cycle time Performance optimization for improvement of internal SLX cycle time. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 494095 online help V1.103 Update online help to V1.103 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 502230 support Acopos P3 (X20SLX210 and X20SLX410 only) X20SLX210 and X20SLX410 support all variants of Acopos P3 (X20SLX910 supports 1 axis only) Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 513925 / Support ID: 400193973, 400206803 SLXbootState 54 SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 516045 fixes for parameters in SafeDESIGNER Minor text corrections. Remove obsolete parameter "Cycle time". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 521125 Adapt filter algorithm to eliminatedependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522940 Error while downloadingbig SafeDESIGNER applications to the SLX. Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522945 Setup Mode and automated acknowledgements - Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher) - new parameters for automated acknowledgement of SafeKEY and firmware exchange. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 528960 SafeOS Status in SafeDESIGNER Remote Control It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions. SafeDESIGNER SafePLC window or AsSafety can be used instead. This affects a set of following versions: SLX Upgrade >=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3 and AR B4.26 to C4.26 or C4.33 to E4.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.0.0: ID: 374990/ Support ID: 400129134 SafeDESIGNER communication Variable status Frequent activating/deactivating of SafeDESIGNER variable status could leadtofailure of SLX communication. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 390095 / Support ID: 400137073 informations about actual application CRC and timestamp of the SafeDESIGNER application that is actually stored on the SLX can be read via asynchronous data points. Channel description changed:Yes Configuration description changed: No Firmware changed: Yes ID: 411790 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 426855 / Support ID: 400151377 Optional modules no longer reported missing via SLX LEDs Channel description changed: No Configuration description changed: No Firmware changed: No ID: 440400 / Support ID: 400147709, 400160605, 400165854, 400175456 Input checksum data error In rare cases itcould happen sporadically that the SLX entered failsafe state with "Input checksum data error" (logger messages 69648, 73744, 69655 und 73751) Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 448715 application download Performance optimization of application download to SLX. Some sequences have been changes for this which omitted some of the values ofSLXbootState. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448980 / Support ID: 400162839, 400168358 limit of max 1 SLX per CPU / line integration If there are more then one SLXin the AS hardware tree, only one of them maybe enabled. On the other hand now it is allowed to download a SafeDESIGNER application that doesn't match the SafeLOGIC-ID of the AS hardware tree. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(320) Version 1.9.2.0: ID: 450785 / Support ID: 400137924 SafeLOGIC-X with Panal PC SafeLOGIC-X didn't work with some Panal PCs (e.g. 5PC901 and 5PPC2100) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313) Version 1.9.1.0: ID: 425385 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425390 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 425395 fw valid from SafetyRelease 1.8 on The firmware is used for all SafetyReleases from 1.8 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425400 Default values changed Default values of Cycle_Time_typical_us and Default_Max_X2X_CycleTime_us changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 4\57992_1.fw(313) Version 1.9.0.0: ID: 419950 The module also supports SafetyRelease 1.9 Starting with this version, the module also supports SafetyRelease 1.9 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 419955 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 2\57992_1.fw(311) Version 1.8.0.3: ID: 393855 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 2\57992_1.fw(311) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.3.2 | * | 07.09.2017 | 5 MB | EXE | AS4_HW_X20SLX210.exe | |
Popis |
V4.0 HW Upgrade (X20SLX210) Revision information X20cSLX410 Version 1.10.3.2: ID: 549110 / Support ID: 400225917 Correction of SLX download frame Correction of SLX download frame Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.3.1: ID: 537600 logger message 110367 with external maschine options SLX did not boot correctly when using external machine options withupgrade V1.10.2.9 (logger message 110367 and others). Channel description changed: No Configuration description changed: No Firmware changed: No ID: 537605 logger message 123416 when aknowledging a firmware mismatch The command for firmware acknowledgement was accepted although there was still a SCAN in progress. This could lead to a failure with loggermessage 123416. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313),5\57992_1.fw(324) Version 1.10.2.9: ID: 381670 / Support ID: 400132230 X20(c)SLX910: warn about invalid two channel processing mode X20(c)SLX910: SafeDESIGNER generates a warning during compile if a two-channel evaluation channel is used but the according parameter "Two Channel Processing Mode" is "none". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 481780 / Support ID: 400199480 error message about incompatible AR version Error message during AutomationStudio compile when trying to use Safety Release 1.10 with an AR version that is too old. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 494085 Improve SLX cycle time Performance optimization for improvement of internal SLX cycle time. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 494095 online help V1.103 Update online help to V1.103 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 502230 support Acopos P3 (X20SLX210 and X20SLX410 only) X20SLX210 and X20SLX410 support all variants of Acopos P3 (X20SLX910 supports 1 axis only) Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 513925 / Support ID: 400193973, 400206803 SLXbootState 54 SLXbootState never reached value 54 "SafeRUN" although SLX booted correctly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 516045 fixes for parameters in SafeDESIGNER Minor text corrections. Remove obsolete parameter "Cycle time". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 521125 Adapt filter algorithm to eliminate dependencies between TON and TOF-filter Filter algorithm was adapted to eliminate dependencies between TON and TOF-filter which existed since FW V301. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522940 Error while downloading bigSafeDESIGNER applications to the SLX. Download was aborted and the message "File Unlock Status: Error while writing unlock status!" was shown. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 522945 Setup Mode and automated acknowledgements - Setup Mode is supported (requires SafeDESIGNER 4.3 and AutomationRuntime B4.26 or higher) - new parameters for automated acknowledgement of SafeKEY and firmware exchange. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID:528960 SafeOS Status in SafeDESIGNER Remote Control It is a known issue that the SafeOS status in SafeDESIGNER remote control is not shown correctly when using certain versions. SafeDESIGNER SafePLC window or AsSafety can be used instead. This affects a set of following versions: SLX Upgrade>=V1.10.2.x, Safety Release 1.10, SafeDESIGNER >=V4.2.3 and AR B4.26to C4.26 or C4.33 to E4.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 4\57992_1.fw(313), 5\57992_1.fw(324) Version 1.10.0.0: ID: 374990 / Support ID: 400129134 SafeDESIGNER communication Variable status Frequent activating/deactivating of SafeDESIGNER variable status could leadto failure of SLX communication. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 390095 / Support ID: 400137073 informations about actual application CRC and timestamp of the SafeDESIGNER application that is actually stored on the SLX can be read via asynchronous data points. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 411790 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 426855 / Support ID: 400151377 Optional modules no longer reported missing via SLX LEDs Channel description changed: No Configuration description changed: No Firmware changed: No ID: 440400 / Support ID: 400147709, 400160605,400165854, 400175456 Input checksum data error In rare cases it could happen sporadically that the SLX entered failsafe state with "Input checksum data error" (logger messages 69648, 73744, 69655 und 73751) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448715 application download Performance optimization of application download to SLX. Some sequences have been changesfor this which omitted some of the values of SLXbootState. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448980 / Support ID: 400162839, 400168358 limit of max 1 SLX per CPU / line integration If there are more then one SLX in the AS hardware tree, only one of them may be enabled. On the other hand now it is allowed to download a SafeDESIGNER application that doesn't match the SafeLOGIC-ID of the AS hardware tree. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 4\57992_1.fw(313), 5\57992_1.fw(320) Version 1.9.2.0: ID:450785 / Support ID: 400137924 SafeLOGIC-X with Panal PC SafeLOGIC-X didn't work with some Panal PCs (e.g. 5PC901 and 5PPC2100) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 4\57992_1.fw(313) Version 1.9.1.0: ID: 425385 change of input filter The behaviour of the input filter has changed. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 425390 Update Online Help Update Online Help V1.91 Channel description changed: No Configuration description changed: No Firmware changed: No ID:425395 fw valid from SafetyRelease 1.8 on The firmware is used for all SafetyReleases from 1.8 on. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 425400 Default values changed Default values of Cycle_Time_typical_us and Default_Max_X2X_CycleTime_us changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 4\57992_1.fw(313) Version 1.9.0.0: ID: 419950 The module also supports SafetyRelease 1.9 Starting with this version, the module also supports SafetyRelease 1.9 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 419955 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 2\57992_1.fw(311) Version 1.8.0.3: ID:393855 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 2\57992_1.fw(311) |