DWL@DWL10000304929
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
|---|---|---|---|---|---|---|
| 1.7.0.0 | * | 01.10.2024 | 1 MB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.7.0.0: ID: TDYD-7029 Incorrectly configured modules were not identified on the X2X bus in certain circumstances. A dynamic hardwareconfiguration is used for various customer applications. In this case, a default configuration is simply created in AS and the actual configuration is readout after the system has started up. Due to a hardware change of several I/O modules, only a cyclic size of 12 bytes (previously 31 bytes) is accepted in the bootloader. If a module with more cyclic data (e.g. a safety module) is nowconfigured, this module can no longer be identified on the bus. As a workaround, these "large" modules can be configured on other X2X slots. This problem can only be corrected with a new bootloader, which can only be delivered via production. Production will be switched to the new software accordingly. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_21.fw(230), 1\42157_5.fw(801) Version 1.6.0.0: ID: 760740 Support new HW variant 21 Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_21.fw(210), 1\42157_5.fw(801) Version 1.5.0.0: ID: 738545 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_5.fw(801) Version 1.4.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.0: ID: 676555 Support hardware variant 11 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_5.fw(801) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmwarechanged: no Version 1.1.0.0: ID: 631795 Support hardwarevariant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 632650 Module documentation revised Data sheet V2.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801) Version 1.0.3.0: ID:467200 Module documentation revised Data sheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID: 394230 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction of data point StatusDigitalOutput08 Data point corrected whenused in function model 254. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunity of output status feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 1.6.0.0 | * | 28.10.2022 | 1,022 KB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.6.0.0: ID: 760740 Support new HW variant 21 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_21.fw(210), 1\42157_5.fw(801) Version 1.5.0.0: ID: 738545 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_5.fw(801) Version 1.4.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.0: ID: 676555 Support hardware variant 11 Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_5.fw(801) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 631795 Support hardware variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 632650 Module documentation revised Data sheet V2.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801) Version 1.0.3.0: ID: 467200 Module documentation revised Data sheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID:394230 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction of data point StatusDigitalOutput08 Data point corrected when used in function model 254. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunity of output status feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 1.5.0.0 | * | 04.11.2021 | 1,012 KB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.5.0.0: ID: 738545 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_20.fw(200), 1\42157_5.fw(801) Version 1.4.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.0: ID: 676555 Support hardware variant 11 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_5.fw(801) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration descriptionchanged: yes Firmware changed: no Version 1.1.0.0: ID: 631795 Support hardware variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 632650 Module documentation revised Data sheet V2.15 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801) Version 1.0.3.0: ID: 467200 Module documentation revised Datasheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID: 394230 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction of data point StatusDigitalOutput08 Data point corrected when used in function model 254. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunity of output status feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 1.4.0.0 | * | 23.07.2021 | 957 KB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.4.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.3.0.0: ID: 676555 Supporthardware variant 11 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_5.fw(801) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 631795 Support hardware variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 632650 Module documentation revised Data sheet V2.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801) Version 1.0.3.0: ID: 467200 Module documentation revised Data sheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID: 394230 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction ofdata point StatusDigitalOutput08 Data point corrected when used in function model 254. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunityof output status feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 1.3.0.0 | * | 06.03.2020 | 952 KB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.3.0.0: ID: 676555 Support hardware variant 11 Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_10.fw(150), 1\42157_11.fw(150), 1\42157_5.fw(801) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 631795 Support hardware variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 632650 Module documentation revised Data sheet V2.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801) Version 1.0.3.0: ID: 467200 Module documentation revised Data sheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID: 394230 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction of data point StatusDigitalOutput08 Data point corrected when used in function model 254. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunity of output status feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 1.2.0.0 | * | 25.10.2019 | 943 KB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 631795 Support hardware variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 632650 Module documentation revised Data sheet V2.15 Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801) Version 1.0.3.0: ID: 467200 Module documentation revised Data sheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID: 394230 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction of data point StatusDigitalOutput08 Data point corrected when used in function model 254. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunity of output status feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 1.1.0.0 | * | 18.02.2019 | 899 KB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.1.0.0: ID: 631795 Support hardware variant 10 Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 632650 Module documentation revised Data sheet V2.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_10.fw(100), 1\42157_5.fw(801) Version 1.0.3.0: ID: 467200 Module documentation revised Data sheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID: 394230 Enhancements packed data point for outputs Channel description changed: Yes Configurationdescription changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction of data point StatusDigitalOutput08 Data point corrected when used in function model 254. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunity of outputstatus feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
| 1.0.3.0 | * | 07.03.2016 | 920 KB | EXE | AS4_HW_X20DO8232.exe | |
| Popis |
V4.0 HW Upgrade (X20DO8232) Revision information X20DO8232 Version 1.0.3.0: ID: 467200 Module documentation revised Data sheet V 3.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.3: ID: 394970 Enhancement online-help files Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.2: ID: 394230 Enhancements packed data point for outputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.1: ID: 333275 Correction of data point StatusDigitalOutput08 Data point corrected when used in function model 254. Channel descriptionchanged: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(801) Version 1.0.2.0: ID: 256450 Increase interference immunity of output status feedbacks Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42157_5.fw(801) Version 1.0.1.1: ID: 215990 Support of asynchronous module status data points Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) Version 1.0.1.0: ID: 185090 HWC correction, correct display of PS status HWC correction, correct display of PS status if dig. status=off Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\42157_5.fw(784) Version 1.0.0.0: ID: 171240 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42157_5.fw(784) |
|||||