DWL@DWL10000317902
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.4.0.0 | * | 23.02.2023 | 1,018 KB | EXE | AS4_HW_X20DI2372.exe | |
Popis |
V4.0 HW Upgrade (X20DI2372) Revision information X20DI2372 Version 1.4.0.0: ID: 766165 Setting "Allow unbalanced on/off variable" can result in a cyclic failure of the module starting with revision D1. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 766170 Failure ModulOK If this module starting with revision D1 is operated behind a bus controller, the network status fails every 10 s (for one X2X cycle). This failure has the following effects. - Local X2X bus: No effect - POWERLINK / Modbus TCP / PROFIBUS / CAN I/O: No effect - CANopen: "Object 0x30B2 Network status OK" failssporadically. - OPC-UA: Flag ModuleOK of the respective X2X module may fail sporadically - EthernetIP / PROFINET / Sercos3 / EtherCAT: - No effectdirectly on the bus controller. - The network status is transferred as BYTE at the beginning of the cyclicdata of the respective X2X station (ModuleOK) and can be evaluated by the respective remote station (data point mapping and evaluation within the application). - Setpoint: 0xF5, in the event of error: 0xF1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_20.fw(230), 1\8871_22.fw(230), 1\8871_5.fw(800) Version 1.3.0.0: ID: 748990 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_20.fw(220), 1\8871_5.fw(800) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405700 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8871_5.fw(800) Version 1.0.1.0: ID: 217390 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_5.fw(800) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.3.0.0 | * | 19.08.2022 | 758 KB | EXE | AS4_HW_X20DI2372.exe | |
Popis |
V4.0 HW Upgrade (X20DI2372) Revision information X20DI2372 Version 1.3.0.0: ID: 748990 Support new HW variant 20 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_20.fw(220), 1\8871_5.fw(800) Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405700 Enhancements packed data point for inputs Channeldescription changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8871_5.fw(800) Version 1.0.1.0: ID: 217390 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_5.fw(800) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.2.0.0 | * | 23.07.2021 | 538 KB | EXE | AS4_HW_X20DI2372.exe | |
Popis |
V4.0 HW Upgrade (X20DI2372) Revision information X20DI2372 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405700 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8871_5.fw(800) Version 1.0.1.0: ID: 217390 Adaptation UART Re-Init Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_5.fw(800) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.1.0.0 | * | 25.10.2019 | 534 KB | EXE | AS4_HW_X20DI2372.exe | |
Popis |
V4.0 HW Upgrade (X20DI2372) Revision information X20DI2372 Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.1.1: ID: 405700 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8871_5.fw(800) Version 1.0.1.0: ID: 217390 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_5.fw(800) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.0.1.1 | * | 11.12.2014 | 555 KB | EXE | AS4_HW_X20DI2372.exe | |
Popis |
V4.0 HW Upgrade (X20DI2372) Revision information X20DI2372 Version 1.0.1.1: ID: 405700 Enhancements packed data point for inputs Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8871_5.fw(800) Version 1.0.1.0: ID: 217390 Adaptation UART Re-Init Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8871_5.fw(800) |