Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.10.12.0 | * | 16.04.2021 | 2 MB | EXE | AS4_HW_X20cSO4120.exe | |
Popis |
V4.0 HW Upgrade (X20cSO4120) Revision information X20cSO4120 Version 1.10.12.0: ID: 691205 / Support ID: 400324199, 400324216, 400329126, 400335782, 400338286 Timing of module internal communication updated The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 710830 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\56668_1.fw(333) Version 1.10.11.0: ID: 692820 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692720 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692620 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\56668_1.fw(332) Version 1.10.10.1: ID: 669900 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(331) Version 1.10.10.0: ID: 622780 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(331) Version 1.10.9.1: ID: 643150 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(330) Version 1.10.9.0: ID: 618270 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(330) Version 1.10.1.1: ID: 422790 / Support ID: 400159073, 400171675, 400201071 Correction for FBK_Status_1 Correction for FBK_Status_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 532525 Improve the description section in the OSDD files Improve the description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532690 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552490 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552520 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(325) Version 1.10.0.6: ID: 532680 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(320) Version 1.9.0.1: ID: 413910 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414090 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414265 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414405 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300) Version 1.6.0.9: ID: 394005 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 3\56668_1.fw(281) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.11.0 | * | 17.09.2020 | 2 MB | EXE | AS4_HW_X20cSO4120.exe | |
Popis |
V4.0 HW Upgrade (X20cSO4120) Revision information X20cSO4120 Version 1.10.11.0: ID: 692820 Improvement of the feedback diagnosis. Improvement of the feedback diagnosis of the output. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692720 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692620 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 6\7958_1.fw(332) Version 1.10.10.1: ID: 669900 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(331) Version 1.10.10.0: ID: 622780 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(331) Version 1.10.9.1: ID: 643150 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(330) Version 1.10.9.0: ID: 618270 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(330) Version 1.10.1.1: ID: 422790 / Support ID: 400159073, 400171675, 400201071 Correction for FBK_Status_1 Correction for FBK_Status_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 532525 Improve the description section in the OSDD files Improve the description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532690 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552490 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552520 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(325) Version 1.10.0.6: ID: 532680 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300), 6\7958_1.fw(320) Version 1.9.0.0: ID: 375000 / Support ID: 400130280 Pindata of outputs Mapping of pindata to outputs was corrected. Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 413840 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413940 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414220 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414340 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281), 4\7958_1.fw(300) Version 1.6.0.9: ID: 393905 Update Online Help Update Online Help V1.80 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.6.0.8: ID: 388410 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.6.0.7: ID: 339260 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.6.0.5: ID: 335430 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335440 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.6.0.0: ID: 313995 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.4.1.8: ID: 303375 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.4.1.7: ID: 290275 Changed help to html format Changed help to html format Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.4.1.3: ID: 284625 Release für kompatibles Safety Release 1.5 ID 284600 Parameter for backwards compatibility in description file changed Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.4.1.1: ID: 180850 Release for Safety Release 1.5 Release for Safety Release 1.5 Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.4.0.1: ID#225425: Safety Release 1.4 - different levels for logger entires: "Info", "Warning" or "Error" (AR B3.05 required) - logger entries with level "Info" or "Warning" are sent by only 1 of the 2safety processors to reduce the number of messages - X2X diagnostics data points (AR 3.08 required) Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Version 1.2.0.3: ID#213410: changes in HWC fixed typos of safety parameters enabled for AR B2.96 Channel description changed: No Configuration description changed: Yes Firmware changed: No Version 1.2.0.0: ID#186435: reduced async communication at boot time parameters are stored locally and will only be transmitted in case of changes Channel description changed: No Configuration description changed: No Firmware changed: No ID#189430: automatic restart An automatic restart can be configured. This enables switching of the digital output without another edge of the release signal. Channel description changed: No Configuration description changed: No Firmware changed: No ID#193060: flashing of SE-LEDs new states of SE-LEDs: single flash: safety firmware is still in state PreOp (waiting for start command from SL) double flash: safety firmware is in operational, but cyclic data connectionto SL is not valid Channel description changed: No Configuration description changed: No Firmware changed: Yes ID#201725: operation in cold environment problemswhen operating in cold environment (0 .. 10°C) solved (logger entries 99850 und 103946) Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.1.5.0: ID#191000: Problems with PhysicalStateChannel The availability of the PhysicalStateChannels is not configurable anymore. This avoids possible mapping problems Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.1.4.0: ID#183545: solved sporadic firmware update problems solved sporadic firmware update problems Channel description changed: No Configuration description changed: No Firmware changed: No Version 1.1.3.0: ID#180215: boot problems at certain X2X cycle times failsafe state during boot when running at certain X2X cycle times (logger entries 119460 and 115364) Channel description changed: No Configuration description changed: No Firmware changed: No ID#182430: enhacements HWC restart inhibit state information can be mapped Aprol support Channel description changed: No Configuration description changed: No Firmware changed: No Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\7958_1.fw(262), 2\7958_1.fw(274), 3\7958_1.fw(281) Version 1.1.2.0: ID: 179300 first official release first official release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7958_1.fw(260) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.10.1 | * | 31.01.2020 | 2 MB | EXE | AS4_HW_X20cSO4120.exe | |
Popis |
V4.0 HW Upgrade (X20cSO4120) Revision information X20cSO4120 Version 1.10.10.1: ID: 669900 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(331) Version 1.10.10.0: ID: 622780 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(331) Version 1.10.9.1: ID: 643150 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(330) Version 1.10.9.0: ID: 618270 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(330) Version 1.10.1.1: ID: 422790 / Support ID: 400159073, 400171675, 400201071 Correction for FBK_Status_1 Correction for FBK_Status_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 532525 Improve the description section in the OSDD files Improve the description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532690 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552490 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552520 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(325) Version 1.10.0.6: ID: 532680 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300), 6\56668_1.fw(320) Version 1.9.0.1: ID: 413910 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414090 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414265 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414405 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56668_1.fw(281), 4\56668_1.fw(300) Version 1.6.0.9: ID: 394005 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 3\56668_1.fw(281) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.9.1 | * | 16.05.2019 | 2 MB | EXE | AS4_HW_X20cSO4120.exe | |
Popis |
V4.0 HW Upgrade (X20cSO4120) Revision information X20cSO4110 Version 1.10.9.1: ID: 643150 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(330) Version 1.10.9.0: ID:618270 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(330) Version 1.10.1.1: ID: 422790 / Support ID: 400159073, 400171675, 400201071 Correction for FBK_Status_1 Correction for FBK_Status_1 Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 532525 Improve the description section in the OSDD files Improve the description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532690 Update ECAD data Update ECADdata Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552490 Provide CRC of theFirmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552520 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(325) Version 1.10.0.6: ID: 532680 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed:Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.9.0.1: ID: 413905 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414075 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414260 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414400 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300) Version 1.6.0.9: ID: 393950 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 3\56708_1.fw(281) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.9.0 | * | 08.11.2018 | 2 MB | EXE | AS4_HW_X20cSO4120.exe | |
Popis |
V4.0 HW Upgrade (X20cSO4120) Revision information X20cSO4110 Version 1.10.9.0: ID: 618270 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(330) Version 1.10.1.1: ID: 422790 / Support ID: 400159073, 400171675, 400201071 Correction for FBK_Status_1 Correction for FBK_Status_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 532525 Improve the description section in the OSDD files Improve the description sectionin the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532690 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552490 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552520 Loggerentry on negativ edge ofSafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(325) Version 1.10.0.6: ID: 532680 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmwarechanged: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.9.0.1: ID: 413905 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in theAS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414075 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414260 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414400 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300) Version 1.6.0.9: ID: 393950 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 3\56708_1.fw(281) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.1.1 | * | 19.03.2018 | 2 MB | EXE | AS4_HW_X20cSO4120.exe | |
Popis |
V4.0 HW Upgrade (X20cSO4120) Revision information X20cSO4110 Version 1.10.1.1: ID: 422790 / Support ID: 400159073, 400171675, 400201071 Correction for FBK_Status_1 Correction for FBK_Status_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 532525 Improve the description section in the OSDD files Improve the description section in the OSDD files Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532690 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 552490 Provide CRC ofthe Firmware Provide CRC of the Firmware Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 552520 Loggerentry on negativ edge of SafeModuleOK If a negativ edge on SafeModuleOK is detected, a logger entry will be generated Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300),6\56708_1.fw(325) Version 1.10.0.6: ID: 532680 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easierparametrizationof timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.9.0.1: ID: 413905 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414075 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed:No ID: 414260 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414400 Update Online Help Update Online HelpV1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300) Version 1.6.0.9: ID: 393950 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 3\56708_1.fw(281) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.10.0.6 | * | 04.10.2017 | 2 MB | EXE | AS4_HW_X20cSO4120.exe | |
Popis |
V4.0 HW Upgrade (X20cSO4120) Revision information X20cSO4110 Version 1.10.0.6: ID: 532680 Add blackout mode Add blackout mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 532685 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.2: ID: 507370 Added information about internal cycletime Added information about internal cycletime Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.10.0.1: ID: 473225 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 473235 Support of release 1.10 including openSAFETY 1.5 Support ofrelease 1.10 including openSAFETY 1.5 with easier parametrizationof timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300), 6\56708_1.fw(320) Version 1.9.0.1: ID: 413905 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414075 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 414260 parameter max. Switching Frequency removed Parameter max. Switching Frequency has no meaning any more. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes ID: 414400 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\56708_1.fw(281), 4\56708_1.fw(300) Version 1.6.0.9: ID: 393950 first official release first official release Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 3\56708_1.fw(281) |