DWL@DWL10000240314
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.2.0.0 | * | 23.07.2021 | 2 MB | EXE | AS4_HW_X20CP3484-1.exe | |
Popis |
V4.0 HW Upgrade (X20CP3484-1) Revision information X20CP3484-1 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.5.0: ID: 429060 Support Bonding feature Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 429165 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(66) Version 1.1.4.0: ID: 358945 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359240 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.1.3.0: ID: 332380 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINKcommunication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337525 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(63) Version 1.1.2.0: ID: 296130 Compatibility to Atom CPU Allows the replacement of a X20CPx48x through X20CPx58x in an existing AS configuration. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7),1\43711b0.epl(60) Version 1.1.1.0: ID: 285890 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286110 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safetylogbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(60) Version 1.1.0.2: ID: 256765 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256885 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 257035 POWERLINK: Supportfor 100 Mbit full duplex in Ethernet operating mode. Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: Yes ID: 260895 POWERLINK: L/A LED only shows Link and not Activity -> corrected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265745 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265845 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(58) Version 1.0.15.1: ID: 230805 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(14), 1\43711_0.pci(7), 1\43711b0.epl(52) Version 1.0.15.0: ID: 223950 Version entry in HWC corrected from V2.94 to R2.95 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\43711a0.pci(14), 1\43711_0.pci(6), 1\43711b0.epl(51) Version 1.0.14.0: ID: 220520 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(14), 1\43711_0.pci(6), 1\43711b0.epl(51) Version 1.0.1.0: ID: 205820 Support of X20CP3484-1 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\43711a0.pci(14), 1\43711_0.pci(6), 1\43711b0.epl(36) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.1.5.0 | * | 15.06.2015 | 2 MB | EXE | AS4_HW_X20CP3484-1.exe | |
Popis |
V4.0 HW Upgrade (X20CP3484-1) Revision information X20CP3484-1 Version 1.1.5.0: ID: 429060 Support Bonding feature Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 429165 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(18),1\43711_0.pci(7), 1\43711b0.epl(66) Version 1.1.3.0: ID: 332380 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337525 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(63) Version 1.1.2.0: ID: 296130 Compatibility to Atom CPU Allows the replacement of a X20CPx48xthrough X20CPx58x in an existing AS configuration. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(60) Version 1.1.1.0: ID: 285890 POWERLINK V2 CN mode: Asynchronouspackets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286110 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) duringstartup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(60) Version 1.1.0.2: ID: 256765 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256885 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 257035 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 260895 POWERLINK: L/A LED only shows Link and not Activity -> corrected. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265745 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265845 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: Whenan iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(18), 1\43711_0.pci(7), 1\43711b0.epl(58) Version 1.0.15.1: ID: 230805 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(14), 1\43711_0.pci(7), 1\43711b0.epl(52) Version 1.0.15.0: ID: 223950 Version entry in HWC corrected from V2.94 to R2.95 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\43711a0.pci(14), 1\43711_0.pci(6), 1\43711b0.epl(51) Version 1.0.14.0: ID: 220520 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\43711a0.pci(14), 1\43711_0.pci(6), 1\43711b0.epl(51) Version 1.0.1.0: ID: 205820 Support of X20CP3484-1 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\43711a0.pci(14), 1\43711_0.pci(6), 1\43711b0.epl(36) |