DWL@DWL10000455461

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.4.1.0 * 01.08.2023 4 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 2.4.1.0:

ID: 773605
Faulty FlatStream initialization corrected
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\60247_1.fw(261), 1\60247_2.fw(261), 1\60247_3.fw(261)

Version 2.4.0.0:

ID: 744095
Adaptations for fieldbus support.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 747005
Corrected stability problem that could occur with certain devices
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 747020
Additional Registers available
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 747035
New documentation 2.65 is available
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 749930 / Support ID: 400372679
Corrected problem with Synchonized0x channels
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(261), 1\60247_2.fw(261), 1\60247_3.fw(261)

Version 2.3.0.0:

ID: 739700 / Support ID: 400362347
Corrected default settings for overcurrent cutoff
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741015
New documentation 1.65 is available
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 741200
revision of the comboboxes
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 742905 / Support ID: 400367910
Support for IO-Link timestamp version 1.1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 743200 / Support ID: 400361430, 400364406, 400362851
Corrected stability problem that could occur with certain devices
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(256), 1\60247_2.fw(256), 1\60247_3.fw(256)

Version 2.2.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.1.0.0:

ID: 705480
Adaptations forfieldbus support in AS4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 717815
Support HW variant 3
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(240), 1\60247_2.fw(240), 1\60247_3.fw(240)

Version 2.0.1.0:

ID: 672745 / Support ID: 400302845
Correction for Automation Studio 3
The parameter CfO_BaudratePrescaler can be written with Library AsIoAcc.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 2.0.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.9.1.0:

ID: 637120
Confusing warning message eliminated
In several versions of AutomationStudio, a confusing warning message could occur. The message was eliminated because it was without any significance for using the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wire interfacerevised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Link device). The extension offers to force one of the identification procedures inAutomationStudio.
Channel description changed: Yes
Configuration descriptionchanged: Yes
Firmware changed: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.4.0.0 * 07.04.2022 4 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 2.4.0.0:

ID: 744095
Adaptations for fieldbus support.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 747005
Corrected stability problem that could occur with certain devices
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 747020
Additional Registers available
Channel description changed:Yes
Configuration description changed: No
Firmware changed: No

ID: 747035
New documentation 2.65 is available
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 749930 / Support ID: 400372679
Corrected problem withSynchonized0x channels
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(261), 1\60247_2.fw(261), 1\60247_3.fw(261)

Version 2.3.0.0:

ID: 739700 / Support ID: 400362347
Corrected default settings for overcurrent cutoff
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741015
New documentation 1.65 is available
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 741200
revision of the comboboxes
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 742905 / Support ID: 400367910
Support for IO-Link timestamp version 1.1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 743200 / Support ID: 400361430, 400364406, 400362851
Corrected stability problem that could occur with certain devices
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(256), 1\60247_2.fw(256), 1\60247_3.fw(256)

Version 2.2.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.1.0.0:

ID: 705480
Adaptations for fieldbus support in AS4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 717815
Support HW variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(240), 1\60247_2.fw(240), 1\60247_3.fw(240)

Version 2.0.1.0:

ID: 672745 / Support ID: 400302845
Correction for Automation Studio 3
The parameter CfO_BaudratePrescaler can be written with Library AsIoAcc.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 2.0.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed:no
Configuration description changed: yes
Firmware changed: no

Version 1.9.1.0:

ID: 637120
Confusing warning message eliminated
In several versions of AutomationStudio, a confusing warning message could occur. The message was eliminated because it was without any significance for using the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wire interface revised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID andserial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now, the identification procedure was defined automatically (given by the IO-Link device). The extension offers to force one ofthe identification procedures in AutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed:Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimizedfor fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. datatransfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.3.0.0 * 30.11.2021 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 2.3.0.0:

ID: 739700 / Support ID: 400362347
Corrected default settings for overcurrent cutoff
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 741015
New documentation 1.65 is available
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 741200
revision of the comboboxes
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 742905 / Support ID: 400367910
Support for IO-Link timestamp version 1.1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 743200 / Support ID: 400361430, 400364406, 400362851
Corrected stability problem that could occur with certain devices
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(256), 1\60247_2.fw(256), 1\60247_3.fw(256)

Version 2.2.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.1.0.0:

ID: 705480
Adaptations for fieldbus support in AS4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 717815
Support HW variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(240), 1\60247_2.fw(240), 1\60247_3.fw(240)

Version 2.0.1.0:

ID: 672745 / Support ID: 400302845
Correction for Automation Studio 3
The parameter CfO_BaudratePrescaler can be written with Library AsIoAcc.
Channel description changed: Yes
Configuration description changed: No
Firmwarechanged: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 2.0.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.9.1.0:

ID: 637120
Confusing warning message eliminated
In several versions of AutomationStudio, a confusing warning message could occur. The message was eliminated because it was without any significance for using the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wire interface revised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Link device). The extensionoffers to force one of the identification procedures in AutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 614515
Communication behavior ofIO-Link master revised
The communication behavior was optimized if thereis no device is connected to an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.2.0.0 * 23.07.2021 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 2.2.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.1.0.0:

ID: 705480
Adaptations for fieldbus support in AS4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 717815
Support HW variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(240), 1\60247_2.fw(240), 1\60247_3.fw(240)

Version 2.0.1.0:

ID: 672745 / Support ID: 400302845
Correction for Automation Studio 3
The parameter CfO_BaudratePrescaler can be written with Library AsIoAcc.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 2.0.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.9.1.0:

ID:637120
Confusing warning message eliminated
In several versions of AutomationStudio, a confusing warning message could occur. The message was eliminated because it was without any significance for using the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wireinterface revised
The TWI driver was revised to improve e.g. the restartbehavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Linkdevice). The extension offers to force one of the identification procedures in AutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behaviorwas optimized if there is no device is connected to an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behaviorof paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM viewrevised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaptionof IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.1.0.0 * 12.03.2021 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 2.1.0.0:

ID: 705480
Adaptations for fieldbus support in AS4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 717815
Support HW variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(240), 1\60247_2.fw(240), 1\60247_3.fw(240)

Version 2.0.1.0:

ID: 672745 / Support ID: 400302845
Correction for Automation Studio 3
The parameter CfO_BaudratePrescaler can be written with Library AsIoAcc.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 2.0.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.9.1.0:

ID: 637120
Confusing warning message eliminated
In several versions of AutomationStudio, a confusing warning message could occur. The message was eliminated because it was without any significance for using the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID:639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wire interface revised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Link device). The extension offers toforce one of the identification procedures in AutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.0.1.0 * 11.12.2019 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 2.0.1.0:

ID: 672745 / Support ID: 400302845
Correction forAutomation Studio 3
The parameter CfO_BaudratePrescaler can be written with Library AsIoAcc.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 2.0.0.0:

ID:
Adaptationsfor Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.9.1.0:

ID: 637120
Confusing warning message eliminated
In several versions of AutomationStudio, a confusing warning message could occur. The message was eliminated because it was without any significance for using the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wire interface revised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID:614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Link device). The extension offers to force one of the identification procedures inAutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than canbetransfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.0.0.0 * 25.10.2019 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 2.0.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.9.1.0:

ID: 637120
Confusing warning message eliminated
In several versions of AutomationStudio, aconfusing warning message could occur. The message was eliminated because it was without any significance for using the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wire interface revised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentationrevised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Link device). The extension offers to force one of the identification procedures inAutomationStudio.
Channel description changed: Yes
Configuration description changed:Yes
Firmware changed: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmwarechanged: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.9.1.0 * 02.04.2019 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 1.9.1.0:

ID: 637120
Confusing warning message eliminated
In several versions of AutomationStudio, a confusing warning message couldoccur. The message was eliminated because it was without any significance forusing the module.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 639445
Module documentation revised
Data sheet V1.50
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.9.0.0:

ID: 632210
Two-wire interface revised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Link device). The extension offers to force one of the identification procedures inAutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.9.0.0 * 21.02.2019 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 1.9.0.0:

ID: 632210
Two-wire interface revised
The TWI driver was revised to improve e.g. the restart behavior of the module.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(133), 1\60247_2.fw(133)

Version 1.8.0.0:

ID: 614495
Module documentation revised
Data sheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedurewas defined automatically (given by the IO-Link device). The extension offersto force one of the identification procedures in AutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.8.0.0 * 13.11.2018 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 1.8.0.0:

ID: 614495
Module documentation revised
Datasheet V1.40
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 614500
Identification procedure of IO-Link device extended
The optional verification of device ID and serial number of the connected IO-Link device can be done according to IO-Link revision 1.0 or 1.1. Up to now,the identification procedure was defined automatically (given by the IO-Link device). The extension offers to force one of the identification procedures inAutomationStudio.
Channel description changed: Yes
Configuration description changed: Yes
Firmwarechanged: Yes

ID: 614515
Communication behavior of IO-Link master revised
The communication behavior was optimized if there is no device is connectedto an activated IO-Link channel.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(132), 1\60247_2.fw(132)

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when moreBytes are defined than can betransfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.7.0.0 * 30.05.2018 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 1.7.0.0:

ID: 596575
Up-/Download behavior of paramerter server revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 596580
Behavior on connection loss revised
In case of connection loss, the "InputData" data points are reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(126)

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message willbe shown, when more Bytes are defined than can betransfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.6.1.1 * 05.09.2017 3 MB EXE AS4_HW_X20cDS438A.exe
Popis V4.0 HW Upgrade (X20cDS438A)

Revision information X20cDS438A

Version 1.6.1.1:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.1.0:

ID: 540035
SDM view revised.
Connected IO-Link devices are shown as connected in SDM view.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(125)

Version 1.6.0.2:

ID: 534175
Adaption of IO-Link baud rate
Baud rate optimized for fast answering IO-Link slaves
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60247_1.fw(125)

Version 1.5.1.0:

ID: 515960
Max. data transfer revised
Warning/Error message will be shown, when more Bytes are defined than can be transfered.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)

Version 1.5.0.1:

ID: 484190
Support X20cDS438A
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60247_1.fw(122)
Loading
Zpět k seznamu

Vyberte prosím zemi a jazyk

B&R Logo