DWL@DWL10000289929
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.3.3.0 | * | 20.03.2024 | 2 MB | EXE | AS4_HW_X20ATA492.exe | |
Popis |
V4.0 HW Upgrade (X20ATA492) Revision information X20ATA492 Version 1.3.3.0: ID: 783515 / Support ID: 400425321 Bugfix within the measurment of external compensation using thermocoupler type K no valuemeasured with thermocouple type K and external compensation (X20TB1F). Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\48024_1.fw(100), 1\48024_2.fw(100) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 562725 Improved reset behavior In rare cases, analog value measurement does not start after a reset. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 659210 Module documentation revised Data sheet V 1.41 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(100), 1\48024_2.fw(100) Version 1.0.2.0: ID: 477160 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.2: ID: 373455 Extension of EPLAN data Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.0: ID: 291955 / Support ID: 400088151 Enhancement english online help and correction of wrong temperature value on overrun Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.0.2: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) Version 1.0.0.0: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.3.0.0 | * | 23.07.2021 | 1 MB | EXE | AS4_HW_X20ATA492.exe | |
Popis |
V4.0 HW Upgrade (X20ATA492) Revision information X20ATA492 Version 1.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 562725 Improved reset behavior In rare cases, analog value measurement does not start after a reset. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 659210 Module documentation revised Data sheet V 1.41 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(100), 1\48024_2.fw(100) Version 1.0.2.0: ID: 477160 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.2: ID: 373455 Extensionof EPLAN data Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.0: ID: 291955 / Support ID: 400088151 Enhancement english online help and correction of wrong temperature value on overrun Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\48024_1.fw(51),1\48024_2.fw(52) Version 1.0.0.2: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) Version 1.0.0.0: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.2.0.0 | * | 25.10.2019 | 1 MB | EXE | AS4_HW_X20ATA492.exe | |
Popis |
V4.0 HW Upgrade (X20ATA492) Revision information X20ATA492 Version 1.2.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.1.0.0: ID: 562725 Improvedreset behavior In rare cases, analog value measurement does not start after a reset. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 659210 Module documentation revised Data sheet V 1.41 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(100), 1\48024_2.fw(100) Version 1.0.2.0: ID: 477160 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.2: ID: 373455 Extension of EPLAN data Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.0: ID: 291955 / Support ID: 400088151 Enhancement english online help and correction of wrong temperature value on overrun Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.0.2: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) Version 1.0.0.0: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.1.0.0 | * | 11.09.2019 | 1 MB | EXE | AS4_HW_X20ATA492.exe | |
Popis |
V4.0 HW Upgrade (X20ATA492) Revision information X20ATA492 Version 1.1.0.0: ID: 562725 Improved reset behavior In rare cases, analog value measurement does not start after a reset. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 659210 Module documentation revised Data sheet V 1.41 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(100), 1\48024_2.fw(100) Version 1.0.2.0: ID: 477160 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.2: ID: 373455 Extension of EPLAN data Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.0: ID: 291955 / Support ID: 400088151 Enhancement english online help and correction of wrongtemperature value onoverrun Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.0.2: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) Version 1.0.0.0: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.0.2.0 | * | 11.05.2016 | 1,013 KB | EXE | AS4_HW_X20ATA492.exe | |
Popis |
V4.0 HW Upgrade (X20ATA492) Revision information X20ATA492 Version 1.0.2.0: ID: 477160 Module documentation revised Data sheet V1.20 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.2: ID: 373455 Extension of EPLANdata Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.1.0: ID: 291955 / Support ID: 400088151 Enhancement english online help and correction of wrong temperature value on overrun Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\48024_1.fw(51), 1\48024_2.fw(52) Version 1.0.0.2: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\48024_1.fw(51), 1\48024_2.fw(51) Version 1.0.0.0: ID: 247905 Support X20ATA492 Support X20ATA492, first version Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\48024_1.fw(51), 1\48024_2.fw(51) |