Revision information 8EIxxxMxT1x.xxxx-1

Version 2.3.2.0:

ID: 728020 / Support ID: 400353504
Wrong description for encoder connector in module configuration
For some modules the description of the encoder connector was wrong.
The description of the encoder connector in the configuration in AS was not the same as on the housing of the module.

Added attribute "Label" for encoder connectors.

-Automation Studio version AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 768625
Support of new ACP P3 modules 8EI*-2
The following modules are now supported:
8EI2X2HCT10.XXXX-2
8EI2X2HWT10.XXXX-2
8EI2X2MCT10.XXXX-2
8EI2X2MWT10.XXXX-2
8EI4X5HCT10.XXXX-2
8EI4X5HWT10.XXXX-2
8EI4X5MCT10.XXXX-2
8EI4X5MWT10.XXXX-2
8EI8X8HCT10.XXXX-2
8EI8X8HWT10.XXXX-2
8EI8X8MCT10.XXXX-2
8EI8X8MWT10.XXXX-2


-Automation Studio version AS 4.0.11
-mapp Motion version 5.24
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.1.2:

ID: 728020 / Support ID: 400353504
Wrong description for encoder connector in module configuration
For some modules the description of the encoder connector was wrong.
The description of the encoder connector in the configuration in AS was not the same as on the housing of the module.

Added attribute "Label" for encoder connectors.

-Automation Studio version AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.1.1:

ID: 707900
Correct display of the DC-Bus Voltage in the speed torque chart.
The DC bus voltage from the configuration of the module is adopted in the Speed ​​Torque Chart.
This function is supported from AS 4.10.
The following upgrades don´t support the Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.3:

ID: 653390
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 683190
Added description "(PLK)" forattribute "Label" for Powerlink connectors
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.2:

ID: 622565
Parameter "SdcEnabled" initializedincorrectly
Data type of parameter was changed to STRING and inital value to "off".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.3.1.1 * 27.11.2020 238 KB EXE AS4_HW_8EIxxxMxT1x.xxxx-1.exe
Popis V4.0 HW Upgrade (8EIxxxMxT1x.xxxx-1)

Revision information 8EI013HCS10.xxxx-1

Version 2.3.1.1:

ID: 707900
Correct display of theDC-Bus Voltage in the speed torque chart.
The DC bus voltage from the configuration of the module is adopted in the Speed ​​Torque Chart.
This function is supported from AS 4.10.
The following upgrades don´t support the Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.1.0:

ID: 446210 / Support ID: 400193653, 400199515, 400216656, 400240315, 400244641, 400259325, 400259805,400264294, 400264504, 400267855, 400276023, 400282533, 400286540, 400293220, 400292633, 400307303, 400307335, 400318959, 400325019, 400330060
Support of Speed Torque Chart in Automation Studio for ACOPOS P3
Extension of thehardware upgrades to support the Speed Torque Chart for ACOPOS P3.
This function is supported from AS 4.10.
The following upgrades don´t support the Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.3:

ID: 653390
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No

ID: 683190
Added description "(PLK)" for attribute "Label" for Powerlink connectors
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.2:

ID: 622565
Parameter "SdcEnabled" initialized incorrectly
Data type of parameter was changed to STRING and inital value to "off".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.3.0.3 * 24.04.2020 238 KB EXE AS4_HW_8EIxxxMxT1x.xxxx-1.exe
Popis V4.0 HW Upgrade (8EIxxxMxT1x.xxxx-1)

Revision information 8EI013HCS10.xxxx-1

Version 2.3.0.3:

ID: 653390
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 683190
Added description "(PLK)" for attribute "Label" for Powerlink connectors
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version2.3.0.2:

ID: 622565
Parameter "SdcEnabled" initialized incorrectly
Data type of parameter was changed to STRING and inital value to "off".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.2.0.0 * 01.09.2017 184 KB EXE AS4_HW_8EIxxxMxT1x.xxxx-1.exe
Popis V4.0 HW Upgrade (8EIxxxMxT1x.xxxx-1)

Revision information 8EI017HWS10.xxxx-1

Version 2.2.0.0:

ID: 549300
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed:No
Firmware changed: No

Version 1.0.0.0:

ID: 520095
HW upgrade for 8EI017HWS10.xxxx-1
HW upgrade for Support of 8EI017HWS10.xxxx-1 within Automation Studio.