V4.0 HW Upgrade (80VD100PS.C03X-01)

DWL@DWL10000327883

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.5.0.0 * 09.09.2020 1 MB EXE AS4_HW_80VD100PS.C03X-01.exe
Popis V4.0 HW Upgrade (80VD100PS.C03X-01)

Revision information 80VD100PD.C000-01

Version 2.5.0.0:

ID: 697735
Support for automatic DNA configuration from AS 4.9.1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.4.0.0:

ID: 625940 / Support ID: 400273146
Fixed bug in Powerlink configuration
Compilation error 6965 with Powerlink configuration Multiplex station fixed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.1:

ID: 590335
Support 8WSAx motors for 80VD100PD.C033-01
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 594020
Support 8WSAx motors for 80VD100PS.C03X-01
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600440
Misconfiguration of mappMotion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is not recognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- Automation Studio V4.4.4
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 610910
80VD100PD.C022-14 HWX entry added
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.2.0.0:

ID: 548710
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.2.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.1.2:

ID: 401905
error in hwx corected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 401935
Eplan data enhanced
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.4.0.0 * 11.03.2019 1 MB EXE AS4_HW_80VD100PS.C03X-01.exe
Popis V4.0 HW Upgrade (80VD100PS.C03X-01)

Revision information 80VD100PD.C000-01

Version 2.4.0.0:

ID: 625940 / Support ID: 400273146
Fixed bug in Powerlink configuration
Compilation error 6965 with Powerlink configuration Multiplex station fixed
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.1:

ID: 590335
Support 8WSAx motors for 80VD100PD.C033-01
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 594020
Support 8WSAx motors for 80VD100PS.C03X-01
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600440
Misconfiguration of mapp Motion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is not recognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- Automation Studio V4.4.4
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 610910
80VD100PD.C022-14 HWX entry added
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.2.0.0:

ID: 548710
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.2.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.1.2:

ID: 401905
error in hwx corected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 401935
Eplan data enhanced
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.3.0.1 * 18.09.2018 1 MB EXE AS4_HW_80VD100PS.C03X-01.exe
Popis V4.0 HW Upgrade (80VD100PS.C03X-01)

Revision information 80VD100PD.C000-01

Version 2.3.0.1:

ID: 590335
Support 8WSAx motors for80VD100PD.C033-01
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 594020
Support 8WSAx motors for 80VD100PS.C03X-01
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 600440
Misconfiguration of mapp Motion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is not recognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- Automation Studio V4.4.4
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 610910
80VD100PD.C022-14 HWX entry added
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.2.0.0:

ID: 548710
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.2.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.1.2:

ID: 401905
error in hwx corected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 401935
Eplan data enhanced
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.2.0.0 * 01.09.2017 1 MB EXE AS4_HW_80VD100PS.C03X-01.exe
Popis V4.0 HW Upgrade (80VD100PS.C03X-01)

Revision information 80VD100PD.C000-01

Version 2.2.0.0:

ID: 548710
Support of motion systemmapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.1.2.0:

ID: 444915
Hwx file corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version1.1.1.2:

ID: 401905
error in hwx corected
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 401935
Eplan data enhanced
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Loading
Zpět k seznamu

Vyberte prosím zemi a jazyk

B&R Logo