V4.0 HW Upgrade (5PPC2100.BY22-002)

DWL@DWL10000444567

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.0.2.0 * 04.12.2018 553 KB EXE AS4_HW_5PPC2100.BY22-002.exe
Popis V4.0 HW Upgrade (5PPC2100.BY22-002)

Revision information 5PPC2100.BY22-002

Version 2.0.2.0:

ID: 621250
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60117_0.fw(113)

Version 2.0.1.0:

ID: 591495
New MTCX version V01.13
New MTCX version V01.13 with following changes.
- Bugfix: Extension units for AP5000 are not recognized sporadically.
- Enhancements for B&R Hypervisor.
- Bugfix -Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a resistive single touch panel and MTCX V01.11.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 1\60117_0.fw(113)

Version 2.0.0.0:

ID: 566580
Preperation to support the B&R Hypervisor
The B&R Hypervisor is supported with Automation Studio version V4.4.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.6.0:

ID: 577805
Problems with resistive touch
The problems with the touch are fixed with the switch back to the MtcX version V1.10.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60117_0.fw(110)

Version 1.0.5.0:

ID: 571425
New MTCX version V01.11
New MTCX version V01.11 with following changes.
- Support for B&R Hypervisor.
- Support for Customer Panel Interface A.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60117_0.fw(111)

Version 1.0.4.0:

ID: 551855
Bugfix for VC4 internal datapoints and illuminated ring keys
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60117_0.fw(108)

Version 1.0.3.0:

ID: 507810
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 537355
NewMTCX version V01.10
New MTCX version V01.10 with following changes.
- Support for 5ACCIF01.FSS0-000.
- Support syncronization byte for BRADI interface over several OS systems.
- Optimized RTC syncronization.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60117_0.fw(110)

Version 1.0.2.0:

ID: 497649
New MTCX version V01.08
New MTCX version V01.08 with following changes.
- Support for 5PPC2100.BY48-00x variants with AR N4.10 or B4.26.
- Bugfix: customized 4-wire touch.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\60117_0.fw(108)

Version 1.0.1.0:

ID: 488460
The module is shown again in the new project wizard
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\60117_0.fw(107)

Version 1.0.0.0:

ID: 469520
Support for 5PPC2100.BYxx-002
The system units 5PPC2100.BYxx-002 are supported beginning with Automation Studio 4.2.5.x and Automation Runtime A4.25 or K4.10.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\60117_0.fw(107)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.0.6.0 * 18.10.2018 543 KB EXE AS4_HW_5PPC2100.BY22-002.exe
Popis V4.0 HW Upgrade (5PPC2100.BY22-002)

Revision information 5PPC2100.BY01-002

Version 1.0.6.0:

ID: 577805
Problems with resistive touch
The problems with the touch are fixed with the switch back to the MtcX version V1.10.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60115_0.fw(110)

Version 1.0.5.0:

ID: 571425
New MTCX version V01.11
New MTCX version V01.11 with following changes.
- Support for B&R Hypervisor.
- Support for Customer Panel Interface A.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60115_0.fw(111)

Version 1.0.4.0:

ID: 551855
Bugfix for VC4 internal datapoints and illuminated ring keys
The internal data points of VC4 and illuminated ring keys are working againfrom Automation Runtime embedded A4.33 on.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\60115_0.fw(110)

Version 1.0.3.0:

ID: 507810
Serial number for 5PPC2100 and 5PC901 read incorrectly by function block and SDM
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 537355
New MTCX version V01.10
New MTCX version V01.10 with following changes.
- Support for 5ACCIF01.FSS0-000.
- Support syncronization byte for BRADI interface over several OS systems.
- Optimized RTC syncronization.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60115_0.fw(110)

Version 1.0.2.0:

ID: 497649
NewMTCX version V01.08
New MTCX version V01.08 with following changes.
- Support for 5PPC2100.BY48-00x variants with AR N4.10 or B4.26.
- Bugfix:customized 4-wire touch.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\60115_0.fw(108)

Version 1.0.1.0:

ID: 488460
The module is shownagain in the new project wizard
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\60115_0.fw(107)

Version 1.0.0.0:

ID: 469520
Support for 5PPC2100.BYxx-002
The system units 5PPC2100.BYxx-002 are supported beginning with Automation Studio 4.2.5.x and Automation Runtime A4.25 or K4.10.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\60115_0.fw(107)