DWL@DWL10000244591

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.1.3.1 * 26.07.2021 380 KB EXE AS4_HW_5PP581.1505-00.exe
Popis V4.0 HW Upgrade (5PP581.1505-00)

Revision information 5PP581.1505-00.1505-00

Version 2.1.3.1:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration descriptionchanged: yes
Firmware changed: no

Version 2.0.3.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.2.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.2:

ID: 344810
The RTOS driver for COM1 must not be installed in the Windows Device Manager
ARwin does not requires RTOS-Driver for COM1 with aktive INA Communication
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.1:

ID: 288025
ARwin: Support for second Ethernet-interface
For support of a second Ethernet interface itwas necassary to introduce a new parameter in hwd-section.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.1.0:

ID: 279565
Important information!
Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xx have a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPUboards), 5PP5IF* (interface boards), 5PP5IO* (I/O boards).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 285420
Preperation to support a second Ethernet interface
-
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.4:

ID: 266995
Support for USB keyboards
USB keyboards can be projected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.3:

ID: 260440
Problem with embedded terminal mode
A problem, that have arisen in connection with the embedded terminal mode, has been fixed.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.2:

ID: 260330
Problem with windows terminal mode
A problem, that have arisen in connection with the windows terminal mode, has been fixed.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.1:

ID: 258955
Problems with terminal modes
Problems, that have arisen in connection with the terminal modes, will be corrected with changes in the respective hardware description files.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 257415
Support for 5PP581.1505-00
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.0.3.0 * 18.07.2016 391 KB EXE AS4_HW_5PP581.1505-00.exe
Popis V4.0 HW Upgrade (5PP581.1505-00)

Revision information 5PP520.0573-00

Version 2.0.3.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.2.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.2:

ID: 344710
The RTOS driver for COM1 must not be installed in the Windows Device Manager
ARwin does not requires RTOS-Driver for COM1 with aktive INA Communication
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.1:

ID: 287945
ARwin: Support for second Ethernet-interface
For support of a second Ethernet interface it was necassary to introduce a new parameter in hwd-section.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.1.0:

ID: 278345
Important information
Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xxhave a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPUboards), 5PP5IF* (interface boards), 5PP5IO* (I / O boards).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 285250
Preperation to support a second Ethernet interface
-
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.5:

ID: 266825
Error in the addressing
Because of collision of USB and COM interface, the USB is postponed to IF2 und IF3.
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: No

Version 1.0.0.4:

ID: 266720
Support for USB keyboards
USB keyboards can be projected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.3:

ID: 259035
Problems with terminal modes
Problems, that have arisen in connection with the terminal modes, will be corrected with changes in the respective hardware description files.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 255455
Support for 5PP520.0573-00
Channel description changed:Yes
Configuration description changed: Yes
Firmware changed: Yes
Loading
Zpět k seznamu

Vyberte prosím zemi a jazyk

B&R Logo