DWL@DWL10000300888

Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
2.2.0.0 * 05.10.2015 591 KB EXE AS4_HW_5PC600.SE00-02.exe
Popis V4.0 HW Upgrade (5PC600.SE00-02)

Revision information 5PC600.SE00-02

Version 2.2.0.0:

ID: 448440
POWERLINK V2: "Controlled node" mode
After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 448445
POWERLINK V2: "Controlled node" mode
In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 448455
Support of Poll Response Chaining on iCN
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 448465
IP packets with multicast addresses not received by the POWERLINK interface
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42283_0.pci(32782), 1\42283b0.can(122), 1\42283b0.epl(128)

Version 2.1.1.0:

ID: 389350 / Support ID: 400137000
Support for UPS in AS4.x added
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42283_0.pci(16397), 1\42283b0.can(122), 1\42283b0.epl(64)

Version 2.0.1.1:

ID: 341900
Ethernet I/O Mapping added
When Modbus is activated, the corresponding data points are available in Automation Studio V4.x.
Channel description changed: Yes
Configuration description changed:No
Firmware changed: No
Firmware: 1\42283_0.pci(13324), 1\42283b0.can(122), 1\42283b0.epl(58)

Version 2.0.1.0:

ID: 268960
New Powerlink firmware V58 added
POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42283_0.pci(13324), 1\42283b0.can(122), 1\42283b0.epl(58)

Version 2.0.0.3:

ID: 267160
Support for USB keyboards
USB keyboards can be projected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42283_0.pci(13323), 1\42283b0.can(122), 1\42283b0.epl(52)

Version 2.0.0.1:

ID: 242925
POWERLINK Firmware and I/O Datapoint
- update POWERLINK Firmware V106
- Link OK status as I/O datapoint for Powerlink added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\42283_0.pci(13323), 1\42283b0.can(122), 1\42283b0.epl(52)