DWL@DWL10000275555
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.1.3.1 | * | 05.03.2014 | 455 KB | EXE | AS4_HW_3IF789.9-1.exe | |
Popis |
V4.0 HW Upgrade (3IF789.9-1) Revision information 3IF789.9-1 Version 1.1.3.1: ID: 370495 picture size adjusted Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(10), 1\7662a0.epl(64) Version 1.1.2.0: ID: 332285 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337430 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7662_0.pci(10), 1\7662a0.epl(63) Version 1.1.1.0: ID: 285925 POWERLINK V2 CN mode: Asynchronous packets lost when there is alarge asynchronous load with large asynchronous frames. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 286145 POWERLINK V2: Large fluctuations of IEEE 1588Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7662_0.pci(10), 1\7662a0.epl(60) Version 1.1.0.2: ID: 256705 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256835 POWERLINK: LinkOK data point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256985 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 265680 POWERLINK V2 CN mode: Frequent MN failuresresult in CPU going into Service mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265785 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with"Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7662_0.pci(10), 1\7662a0.epl(58) Version 1.0.15.0: ID: 230770 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7662_0.pci(9), 1\7662a0.epl(52) Version 1.0.14.0: ID: 220455 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7662_0.pci(9), 1\7662a0.epl(51) Version 1.0.12.0: ID: 206850 New POWERLINK firmware V45 and basis firmware V9 POWERLINK V2 CN mode: - Frequent MNfailures result in CPU going into Service mode. - The PollResponse data from multiplexed stations are now updated in every POWERLINK cycle. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7662_0.pci(9), 1\7662a0.epl(45) Version 1.0.11.0: ID: 199535 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\7662_0.pci(8), 1\7662a0.epl(44) Version 1.0.10.1: ID:191765 New POWERLINK V1/V2 Firmware V42 and base firmware V8 - Error correction for POWERLINK V2: After network disturbances, failed stations were left out of cyclic traffic. - Error correction POWERLINK V2 CN mode: Failure of a SoC resulted immediately in incorrect failure detection by manager. - Error correction: Configuring too small values for PollResponse timeouts caused manager to fail. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(8), 1\7662a0.epl(42) Version 1.0.9.0: ID: 183670 NewPOWERLINK V1/V2 firmware V38 - Error correction for POWERLINK V2: Parameter "CycleIdleTime" was not calculated correctly. - Error correction: ModbusTCP on POWERLINK interfaces was not working. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(7), 1\7662a0.epl(38) Version 1.0.8.0: ID: 178020 New POWERLINK V1/V2 firmware V37 Error corrections: - POWERLINK V2 CN mode: Various error corrections made. - POWERLILNK V2: Asynchronous frames can now be received with the Powerlinklibrary starting with channel >= 0x20 (previously starting with 0xA0). Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\7662_0.pci(7), 1\7662a0.epl(37) Version 1.0.7.0: ID: 173325 New POWERLINK firmware V36 and Base-Firmware V7 Error correction: - When using an I/O prescaler > 1, in certain circumstances the old input data for the station is provided to the application. - With the option 'Fast reaction' and multiplexed station the POWERLINK manager fails when there is a disturbance on the network. Changes - POWERLINK V2: - The poll response from the manager is now sent at the beginning of the POWERLINK cycle. - From now on, stations are addressed with poll requests starting in status"PreOperational 2". Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(7), 1\7662a0.epl(36) Version 1.0.6.0: ID: 171380 Stabilized and optimized. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(6), 1\7662a0.epl(35) Version 1.0.5.0: ID:165805 New POWERLINK V1/V2 Firmware V34 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(5), 1\7662a0.epl(34) Version 1.0.4.0: ID: 165445 New POWERLINK V1/V2 Firmware V33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(5), 1\7662a0.epl(33) Version 1.0.3.0: ID: 164760 New POWERLINK V1/V2 Firmware V31 - Optimizations for EPL V2 startup carried out. - Nettime IEEE 1588 for EPL V2 implemented. - From now on, the asynchronous scheduler will handle asynchronous requestsbased on their priority. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(5), 1\7662a0.epl(31) Version 1.0.2.0: ID: 163855 New Base Firmware V5 Error correction: problems when booting Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(5), 1\7662a0.epl(30) Version 1.0.1.0: ID: 160745 New POWERLINK V1/V2 Firmware V30 In "Controlled Node" mode, the following errors may occur: - With heavy asynchronous loads, asynchronous TX packets may be lost. - Collisions on the network can cause the station to stop receiving Ethernet packets. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\7662_0.pci(4), 1\7662a0.epl(30) |