DWL@DWL10000344422
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.4.2.0 | * | 08.06.2017 | 2 MB | EXE | AS3.0_HW_X20CP1586.exe | |
Popis |
V3.0 HW Upgrade (X20CP1586) Revision information X20CP1586 Version 1.4.2.0: ID: 538775 / Support ID: 400204420 POWERLINK V2: noasynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\50096_0.pci(17), 1\50096a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed:No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware:1\50096_0.pci(17), 1\50096a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\50096_0.pci(17), 1\50096a0.epl(129) Version 1.3.0.0: ID: 462595 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462690 Update online help Channel description changed: No Configurationdescription changed: No Firmware changed: No ID: 462765 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462855 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\50096_0.pci(17), 1\50096a0.epl(129) Version 1.2.0.0: ID: 443685 / Support ID: 400154848 IP packets with multicast addresses not received by thePOWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 444270 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No ID: 445105 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\50096_0.pci(15), 1\50096a0.epl(128) Version 1.1.0.0: ID: 417190 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417265 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417330 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417455 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 423975 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424080 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\50096_0.pci(15), 1\50096a0.epl(127) Version 1.0.5.0: ID: 369285 / Support ID: 400125677 Sporadic error when starting the onboard POWERLINK interface A firmware problem sometimes caused the onboard POWERLINK interface to freeze when booting the CPU. The error message "30257, POWERLINK: Internal error in the driver, IF3: timeout on starting firmware" was output to the logbook. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.0.4.0: ID: 359015 POWERLINK MN mode: If "Multiplexing prescale" >= 9, then the input data of the multiplexed stations that were configured in the last "network cycle" were not transferred in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 359250 / Support ID: 400113446 POWERLINK V2 MN mode: Asynchronous connection losses may occur as a result of high asynchronous loads on the POWERLINK network and high loads on the CPU. This could maintain you to an error 32205 Timeout while writing par. via acyclic channel. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360220 POWERLINK V1 MN mode Error correction: Cyclic input data and net time toggle between the last two received values when CNs drop out. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 360280 / Support ID: - POWERLINK V1 MN mode: "Nettime SoC" is not increased. Channel description changed: No Configuration description changed: No Firmware changed: Yes Version 1.0.3.0: ID: 342580 / Support ID: 400113132 Half-duplex Ethernet connections are not detected when using "Ethernet" operating mode with baud rate "100 MBit auto". This reduces total data throughput. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\50096_0.pci(11), 1\50096a0.epl(123) Version 1.0.2.0: ID: 332360 / Support ID: 400092134 POWERLINK V1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. Thefollowing configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the network that also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 336735 POWERLINK V2 MN mode: It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 337500 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\50096_0.pci(11), 1\50096a0.epl(120) Version 1.0.1.4: ID: 307285 EnhancementEnglish online-help and error corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\50096_0.pci(11), 1\50096a0.epl(117) Version 1.0.1.3: ID: 285205 Support X20CP1586 First Version Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\50096_0.pci(11), 1\50096a0.epl(117) |