DWL@DWL10000334118
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.1.6.0 | * | 15.06.2015 | 3 MB | EXE | AS3.0_HW_X20CP1483.exe | |
Popis |
V3.0 HW Upgrade (X20CP1483) Revision information X20CP1483 Version 1.1.6.0: ID: 429020 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 429125 / Support ID: 400151182 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\44377_0.pci(43), 1\41529a0.epl(66) Version 1.1.5.0: ID: 381575 /Support ID: 400133153 Enhancement documentation Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\41529_0.pci(7), 1\44377_0.pci(43), 1\41529a0.epl(64) Version 1.1.3.0: ID: 332315 / Support ID: 400092134 POWERLINKV1: If the "Activate Ethernet communication off" option is enabled, asynchronous POWERLINK communication fails in some circumstances. The following configuration may cause asynchronous communication to fail: - POWERLINK V1 - "Activate Ethernet communication off" - POWERLINK CNs on the networkthat also support POWERLINK V2 This upgrade can be installed to resolve this problem. It is also possible toset "Activate Ethernet communication" to "On". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 337355 / Support ID: 400108118 POWERLINK V2 CN mode It was possible that an undefined state occurred during booting that causedthe interface to fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\44377_0.pci(43), 1\41529a0.epl(63) Version 1.1.2.0: ID: 296065 Compatibility to Atom CPU Allows the replacement of a X20CPx48x through X20CPx58x in an existing AS configuration. Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No Firmware: 1\41529_0.pci(7), 1\44377_0.pci(43), 1\41529a0.epl(60) Version 1.1.1.0: ID: 285835 POWERLINK V2 CN mode: Asynchronous packets lost when there is a large asynchronous load with large asynchronous frames. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 286035 POWERLINK V2: Large fluctuations of IEEE 1588 Nettime (used for safety logbook entries) during startup. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\44377_0.pci(43), 1\41529a0.epl(60) Version 1.1.0.2: ID: 256715 / Support ID: 400057319 POWERLINK: In controlled node mode, the I/O mapping was not applied when the manager was restarted. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 256850 POWERLINK: LinkOKdata point added. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 256995 POWERLINK: Support for 100 Mbit full duplex in Ethernet operating mode. Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 265705 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 265805 Warning 32168 "POWERLINK V2: Invalid frame format" on iCN with "Chaned Station" on the same network Error correction: When an iCN is used in the same POWERLINK network with a "Chained Station", there may be warnings 32168 in the logger. The reason for this warning is that the sync response frames that are used to measure the timing of the "Chained Station" are not recognized by the iCN. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 266100 Enhancement status datapoint for I/O supply Channel descriptionchanged: Yes Configuration description changed: No Firmware changed: No Firmware: 1\41529_0.pci(7), 1\44377_0.pci(43), 1\41529a0.epl(58) Version 1.0.16.0: ID: 240370 FPGA Fitter upgrade Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\44377_0.pci(42), 1\41529a0.epl(52) Version 1.0.15.0: ID: 230775 POWERLINK V2 CN mode: Frequent MN failures result in CPU going into Servicemode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\44377_0.pci(40), 1\41529a0.epl(52) Version 1.0.14.0: ID: 220465 POWERLINK V2: Boot behavior improved Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\44377_0.pci(40), 1\41529a0.epl(51) Version 1.0.13.0: ID: 198435 / Support ID: 400018078 HW Revison B5 or higher necessary Channel description changed: No Configuration description changed: No Firmware changed: No ID: 213075 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\44377_0.pci(40), 1\41529a0.epl(47) Version 1.0.11.0: ID: 199580 New POWERLINK V1/V2 firmware V44 CN mode: Various error corrections made. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\41529a0.epl(44) Version 1.0.1.0: ID: 197980 Support of CP1483 Support of CP1483 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\41529_0.pci(7), 1\41529a0.epl(42) Version 1.0.0.0: ID: 167535 Support of X20CP1483 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\41529_0.pci(7), 1\41529a0.epl(42), 1\56616_1.fw(10) |