1.1.1.0 * 19.07.2018 4 MB EXE AS3.0_HW_X20cAI2438.exe
Popis V3.0 HW Upgrade (X20cAI2438)

Revision information X20cAI2438

Version 1.1.1.0:

ID: 603829
APROL: Missing attribute for channel-parameter with "Sig_*" inserted
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(100)

Version 1.1.0.0:

ID: 562730 / Support ID: 400231500
Improved reset behavior
In rare cases, analog value measurement does not start after a reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 571630
Module documentation revised
Data sheet V1.24
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(100)

Version 1.0.8.1:

ID: 520405
De-/Activation of subtitution mode revised
The feature "subtitution mode" can be deactivated completely.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 520640
Module documentation revised
Data sheet V 1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version 1.0.7.0:

ID: 492165
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499420
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 499425
Module documentation revised
Data sheet V 1.11
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 503185
Correction of Ecad data (EPlan)
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version 1.0.6.5:

ID: 492165
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499420
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 499425
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version 1.0.0.3:

ID: 402930/ Support ID: 400142019
Multiplexed mode revised
FIO datapionts formultiplexed mode corrected.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version 1.0.0.2:

ID: 297620
Support X20cAI2438
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.1.0.0 * 09.01.2018 4 MB EXE AS3.0_HW_X20cAI2438.exe
Popis V3.0 HW Upgrade (X20cAI2438)

Revision information X20cAI2438

Version 1.1.0.0:

ID: 562730 / Support ID: 400231500
Improved resetbehavior
In rare cases, analog value measurement does not start after a reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 571630
Module documentation revised
Data sheet V1.24
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(100)

Version 1.0.8.1:

ID: 520405
De-/Activation of subtitution mode revised
The feature "subtitution mode" can be deactivated completely.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 520640
Module documentation revised
Data sheet V 1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version 1.0.7.0:

ID: 492165
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499420
Supportfor module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 499425
Module documentation revised
Data sheet V 1.11
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 503185
Correction of Ecad data (EPlan)
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version1.0.6.5:

ID: 492165
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 499420
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 499425
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version 1.0.0.3:

ID: 402930 / Support ID: 400142019
Multiplexed mode revised
FIO datapionts for multiplexed mode corrected.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)

Version 1.0.0.2:

ID: 297620
Support X20cAI2438
Support for Automation Studio
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\57838_2.fw(90)