DWL@DWL10000077979
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.9.0.0 | * | 12.04.2016 | 1 MB | EXE | AS3.0_HW_80SD100XD.C04X-13.exe | |
Popis |
V3.0 HW Upgrade (80SD100XD.C04X-13) Revision information 80SD100XD.C04X-13 Version 1.9.0.0: ID: 474120 Error correction in order to guard motor outputs against short to ground Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_1.fw(2), 1\42893_2.fw(106), 1\42893_3.fw(106), 1\42893_4.fw(106), 1\42893_5.fw(106) Version 1.8.0.0: ID: 400820 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 400875 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 400975 Corrected a problem in HWX file Channel description changed: No Configuration description changed:No Firmware changed: No ID: 440975 / Support ID: 400133806 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No ID: 440985 Support for HW-Variant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_1.fw(2), 1\42893_2.fw(104), 1\42893_3.fw(104), 1\42893_4.fw(104) Version 1.6.2.0: ID: 319005 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 320770 Accelerated firmware update. Allows reliable firmware update behind CANIO bus controllers. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_1.fw(2), 1\42893_2.fw(9), 1\42893_3.fw(9) Version 1.6.1.0: ID: 301465 Support for HW-Variant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_1.fw(2), 1\42893_2.fw(8), 1\42893_3.fw(8) Version 1.6.0.0: ID: 284835 / Support ID: 400084530 Encoder position should be displayed at PosVal03, if SDC information is setto "on" Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42882_1.fw(2), 1\42893_2.fw(8) Version 1.5.3.0: ID: 296380 / Support ID: 400087355 80SD100XD.C04X-13: Erroneous Detection of Short Circuit between Motor-Phaseand Ground Due to a Firmware-Error the activation of the Controller could be blocked under certain circumstances because of a wrongly assumed Short Circuit to Ground Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_1.fw(2), 1\42893_2.fw(8) Version 1.5.2.0: ID: 290315 / Support ID: 400082483 In rare cases ACOPOSmicro generated an erroneous status indication (UZKStatus = not OK). Also high motor currents in conjunction with tolerances of electronic components could lead to module internal disturbances whichin consequence could generate error messages. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_1.fw(2), 1\42893_2.fw(7) Version 1.5.1.0: ID: 272375 / Support ID: 400049998 Module in undefined state, if no trigger happens in mode -121 (Remaining distance mode) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 272380 / Support ID: 400051695 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 272385 Ramp mode: Wrong configuratin for referencing speed is possible Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42882_1.fw(2), 1\42893_2.fw(6) Version 1.4.0.2: ID: 251830 / Support ID: 400056193 Special character were deleted in channel description Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42882_1.fw(2), 1\42893_2.fw(5) Version 1.4.0.1: ID: 243230 Customer-specific expansion of hardware description file This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42882_1.fw(2), 1\42893_2.fw(5) Version 1.1.0.0: ID: 205515 Buscontroller support for the module 80SD100XD.C04X-13 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42882_1.fw(2), 1\42893_2.fw(3) |