DWL@DWL10000299196
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.2.1.0 | * | 06.11.2020 | 2 MB | EXE | AS2.6_HW_X20SM1436.exe | |
Popis |
V2.7 HW Upgrade (X20SM1436) Revision information X20SM1436 Version 2.2.1.0: ID: 698500 Function model names adapted Uniform function model names for all stepper modules Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200), 1\9858_3.fw(100) Version 2.2.0.0: ID: 669455 Support for mappMotion Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 672140 Module documentation revised Data sheet V1.51 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200), 1\9858_3.fw(100) Version 1.6.0.0: ID: 664680 support for HW-variant 3 Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200), 1\9858_3.fw(100) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed:no Configuration description changed: yes Firmware changed: no Version 1.4.3.0: ID: 654565 Corrections made in the hwc file Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 654580 Module documentation revised Datasheet V1.50 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.1: ID: 474750 Motion Wizzard revised In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.0: ID: 477695 Module documentation revised Data sheet V1.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.1.0: ID: 472555 Module documentation revised Data sheet V1.31 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.0.0: ID: 393610 / Support ID: 400138463 HWX File adapted Channel description changed: No Configuration description changed: No Firmware changed: No ID: 455010 Minimum speed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458685 Module documentation revised Datasheet V1.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.3.1.3: ID: 285805/ Support ID: 400084923 Documentation updated- Documentation updated Channel description changed: No Configuration description changed:No Firmware changed: No ID: 406950 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406975 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.2: ID: 387525 Correction of the documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.1: ID: 387045 Extended configuration forAS4 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.0: ID: 246215 / Support ID: 400051036 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 374760 Fixed a bug in the encoder emulation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 377010 / Support ID: 400130169 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.2.6.0: ID: 331150 / Support ID: 400108315 Acyclic read access to the registers for holding/rated/maximum current. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(14), 1\9858_2.fw(14) Version 1.2.4.0: ID: 322200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 326390 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.3.0: ID: 287220 Support HW 2 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.2.0: ID: 267135 Problem with the endswitch-reset at ramp mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 267990 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(13) Version 1.0.3.0: ID: 194010 / Support ID: 400014309 Threshold value for module overtemperature corrected Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(7) Version 1.0.0.0: ID: 164465 Support of the moduleX20SM1436 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.2.0.0 | * | 17.12.2019 | 2 MB | EXE | AS2.6_HW_X20SM1436.exe | |
Popis |
V2.7 HW Upgrade (X20SM1436) Revision information X20SM1436 Version 2.2.0.0: ID: 669455 Support for mappMotion Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 672140 Module documentation revised Data sheet V1.51 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200), 1\9858_3.fw(100) Version 1.6.0.0: ID: 664680 support for HW-variant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200), 1\9858_3.fw(100) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.3.0: ID: 654565 Corrections made in the hwc file Channel description changed: Yes Configuration description changed:Yes Firmware changed: No ID: 654580 Module documentation revised Datasheet V1.50 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.1: ID: 474750 Motion Wizzard revised In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.0: ID: 477695 Module documentation revised Data sheet V1.32 Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.1.0: ID: 472555 Moduledocumentation revised Data sheet V1.31 Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.0.0: ID: 393610 / Support ID: 400138463 HWX File adapted Channel description changed: No Configuration description changed: No Firmware changed: No ID: 455010 Minimum speed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458685 Module documentation revised Datasheet V1.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.3.1.3: ID: 285805 / Support ID: 400084923 Documentation updated- Documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406950 Corrected a problem inHWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406975 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.2: ID: 387525 Correction of the documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.1: ID: 387045 Extended configuration for AS4 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.0: ID: 246215 / Support ID: 400051036 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 374760 Fixed a bug in the encoder emulation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 377010 / Support ID: 400130169 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.2.6.0: ID: 331150 / Support ID: 400108315 Acyclic read access to the registers for holding/rated/maximum current. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(14), 1\9858_2.fw(14) Version 1.2.4.0: ID: 322200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 326390 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13),1\9858_2.fw(13) Version 1.2.3.0: ID: 287220 Support HW 2 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.2.0: ID: 267135 Problem with the endswitch-reset at ramp mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 267990 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(13) Version 1.0.3.0: ID: 194010 / Support ID: 400014309 Threshold value for moduleovertemperature corrected Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(7) Version 1.0.0.0: ID: 164465 Support of the module X20SM1436 Channel description changed: No Configuration description changed: No Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.6.0.0 | * | 19.11.2019 | 2 MB | EXE | AS2.6_HW_X20SM1436.exe | |
Popis |
V2.7 HW Upgrade (X20SM1436) Revision information X20SM1436 Version 1.6.0.0: ID: 664680 support for HW-variant 3 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200), 1\9858_3.fw(100) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.3.0: ID: 654565 Corrections made in the hwc file Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 654580 Module documentation revised Datasheet V1.50 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.1: ID: 474750 Motion Wizzard revised In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.0: ID: 477695 Module documentation revised Data sheet V1.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.1.0: ID: 472555 Module documentation revised Data sheet V1.31 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.0.0: ID: 393610 / Support ID: 400138463 HWX File adapted Channel description changed: No Configuration description changed: No Firmware changed: No ID: 455010 Minimumspeed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458685 Module documentation revised Datasheet V1.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.3.1.3: ID: 285805 / Support ID: 400084923 Documentation updated- Documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406950 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406975 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.2: ID:387525 Correction of the documentation Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.1: ID: 387045 Extended configuration for AS4 Channel description changed:No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.0: ID: 246215 / Support ID: 400051036 Function model Ramp: new mode Mode-120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 374760 Fixed a bug in the encoder emulation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 377010 / Support ID: 400130169 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.2.6.0: ID: 331150 / Support ID: 400108315 Acyclic read access to the registers for holding/rated/maximum current. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(14), 1\9858_2.fw(14) Version 1.2.4.0: ID: 322200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed:No ID: 326390 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.3.0: ID: 287220 Support HW 2 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.2.0: ID: 267135 Problem with the endswitch-reset at ramp mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 267990 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(13) Version 1.0.3.0: ID: 194010 / Support ID: 400014309 Threshold value for module overtemperature corrected Channeldescription changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(7) Version 1.0.0.0: ID: 164465 Support of the module X20SM1436 Channel description changed: No Configuration description changed: No Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.4.3.0 | * | 06.08.2019 | 2 MB | EXE | AS2.6_HW_X20SM1436.exe | |
Popis |
V2.7 HW Upgrade (X20SM1436) Revision information X20SM1436 Version 1.4.3.0: ID: 654565 Corrections made in the hwc file Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 654580 Module documentation revised Datasheet V1.50 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.1: ID: 474750 Motion Wizzard revised In AS 4.x, the aged library "AsString" won’t be added to a AS project anymore. The "AsBrStr" will be used by the Motion instead. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.2.0: ID: 477695 Module documentation revised Data sheet V1.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.1.0: ID: 472555 Module documentation revised Data sheet V1.31 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.0.0: ID: 393610 / Support ID: 400138463 HWX File adapted Channel description changed: No Configuration description changed: No Firmware changed: No ID: 455010 Minimum speed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458685 Module documentation revised Datasheet V1.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.3.2.1: ID: 405140 / Support ID: 0 Text inserted into documentation Channel description changed: No Configuration description changed: No Firmware changed: No ID: 409925 / Support ID: 400144997 extended HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 428925 renewed documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.3: ID: 285805 / Support ID: 400084923 Documentation updated- Documentation updated Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406950 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406975 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.2: ID: 387525 Correction of the documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.1: ID: 387045 Extended configuration for AS4 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.0: ID: 246215 / Support ID: 400051036 Function model Ramp: new mode Mode -120: Set homeposition Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 374760 Fixed a bug inthe encoder emulation Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 377010 / Support ID: 400130169 Cycle time of MPGen edjustable Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.2.6.0: ID: 331150 / Support ID: 400108315 Acyclic read access to the registers for holding/rated/maximum current. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(14), 1\9858_2.fw(14) Version 1.2.4.0: ID: 322200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 326390 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.3.0: ID: 287220 Support HW 2 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.2.0: ID: 267135 Problem with the endswitch-reset at ramp mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 267990 The ACOPOSMicro doesn't switch in switched on with a customermotor at ramp mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(13) Version 1.0.3.0: ID: 194010 / Support ID: 400014309 Threshold value for module overtemperature corrected Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(7) Version 1.0.0.0: ID: 164465 Support of the module X20SM1436 Channel description changed: No Configuration description changed: No Firmware changed: No |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
1.4.2.0 | * | 11.05.2016 | 2 MB | EXE | AS2.6_HW_X20SM1436.exe | |
Popis |
V2.7 HW Upgrade (X20SM1436) Revision information X20SM1436 Version 1.4.2.0: ID: 477695 Module documentation revised Data sheet V1.32 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.1.0: ID: 472555 Module documentation revised Data sheet V1.31 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.4.0.0: ID: 393610 /Support ID: 400138463 HWX File adapted Channel description changed:No Configuration description changed: No Firmware changed: No ID: 455010 Minimum speed for stall detection is now configurable Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 458685 Module documentation revised Datasheet V1.30 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(200), 1\9858_2.fw(200) Version 1.3.2.1: ID: 405140 / Support ID: 0 Text inserted into documentation Channel description changed: No Configuration description changed: No Firmware changed: No ID: 409925 / Support ID: 400144997 extended HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 428925 renewed documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.3: ID: 285805 / Support ID: 400084923 Documentation updated- Documentation updated Channel description changed: No Configurationdescription changed: No Firmware changed: No ID: 406950 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmware changed: No ID: 406975 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.2: ID: 387525 Correction of the documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.1: ID: 387045 Extended configuration for AS4 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.3.1.0: ID: 246215 / SupportID: 400051036 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 374760 Fixed a bug in theencoder emulation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 377010 / Support ID: 400130169 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(16), 1\9858_2.fw(16) Version 1.2.6.0: ID: 331150 / Support ID: 400108315 Acyclic read access to the registers for holding/rated/maximum current. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(14), 1\9858_2.fw(14) Version 1.2.4.0: ID: 322200 Extension of EPLAN data Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 326390 Wrong description corrected Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.3.0: ID: 287220 Support HW 2 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9858_1.fw(13), 1\9858_2.fw(13) Version 1.2.2.0: ID: 267135 Problem with the endswitch-reset at ramp mode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:267990 The ACOPOSMicro doesn't switch in switched on with a customer motor at rampmode. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9858_1.fw(13) Version 1.0.3.0: ID: 194010 / Support ID: 400014309 Threshold value for module overtemperature corrected Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9858_1.fw(7) Version 1.0.0.0: ID: 164465 Support of the module X20SM1436 Channel description changed: No Configuration description changed: No Firmware changed: No |