DWL@DWL10000062192
| Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
|---|---|---|---|---|---|---|
| 1.1.1.0 | * | 16.03.2016 | 1,016 KB | EXE | AS2.6_HW_X20PS2110.exe | |
| Popis |
V2.7 HW Upgrade (X20PS2110) Revision information X20PS2110 Version 1.1.1.0: ID: 471015 Module documentation revised Data sheet V3.20 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(817) Version 1.1.0.0: ID: 463985 General adaptions in hardware files Adaptions to maintain hardwarefiles of X20 and X20c modules more easily Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 464095 Currently produced Firmware added Firmware for HW variant 7 published in AS Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(817) Version 1.0.4.0: ID: 456485 Documentation update in reference to standards Channel description changed: No Configuration description changed: No Firmware changed: No ID: 459430 Adaption for AS4 - AutoConnect changed to X20BM01 - Accessory X20BM05 added to documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800) Version 1.0.3.0: ID: 260530 / Support ID: 400061307 Error correction in channel description Adverse settings in the AS I/O configuration maycause an error on X2X Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800) Version 1.0.2.0: ID:227890 Extension in IO-Mapping for SG3 CanIO Datapoint for Bus voltage added Channel description changed: Yes Configuration descriptionchanged: No Firmware changed: No Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800) Version 1.0.1.1: ID: 176385 Correction HWC display of data point "SupplyVoltage" on Powerlink-BC Correction HWC display of data point "SupplyVoltage" on Powerlink-BC Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800) Version 1.0.0.1: ID: 166175 New FW V800 and HWC V1.0.0.1 New diagnostic data fuse status Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8214_5.fw(784), 1\8214_6.fw(784), 1\8214_7.fw(800) |
|||||