1.1.1.0 * 19.07.2018 3 MB EXE AS2.6_HW_X20AI2438.exe
Popis V2.7 HW Upgrade (X20AI2438)

Revision information X20AI2438

Version 1.1.1.0:

ID: 603819
APROL: missing attribute for channel-Parameter with "Sig_*" inserted
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(100), 1\45993_2.fw(100)

Version 1.1.0.0:

ID: 562740 / Support ID: 400231500
Improved reset behavior
In rare cases, analog value measurement does not start after a reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 571600
Module documentation revised
Data sheet V1.24
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(100), 1\45993_2.fw(100)

Version 1.0.8.1:

ID: 536345
Module documentation revised
Data sheet V1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.8.0:

ID: 519095
De-/Activation of subtitution mode revised
The feature "subtitution mode" can be deactivated completely.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 529665
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.7.0:

ID: 464800
Ecad data (EPlan) corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 466820
Support for module DTM revised
The user defineditem designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No

ID: 476495
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 497215
Module documentation revised
Data sheet V 1.11
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.6.5:

ID: 466820
Supportfor module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 476495
DTM diagnose revised
DTM diagnosis function can beused on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 497215
Module documentation revised
Data sheet V1.10
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.6.0:

ID: 434345
Correction hwx/hwc
wrong MaxInSize-declaration
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.4.2:

ID: 402900 / Support ID: 400142019
Multiplexed mode revised
FIO datapionts for multiplexed mode corrected.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.4.0:

ID: 366205
Compilation of homogeneous Channel Description/Channels section
Module family: "HART" (20Ax243x)

- Adaption of Descriptions and order of registers (IO-Mapping)
- Adaption of asynchronous HART communication
--> Asynchronous request of data points PvSampleTime adapted to documentation.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 368295
Parameter ID adapted to DPS driver
Anpassung of Parameter ID "Taskclass" to DPS stream
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.3.1:

ID: 366205
Compilation of homogeneous Channel Description/Channels section
Module family: "HART" (20Ax243x)

- Adaption of Descriptions and orderof registers (IO-Mapping)
- Adaption of asynchronous HART communication
--> Asynchronous request of data points PvSampleTime adapted to documentation.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 368295
Parameter ID adapted to DPS driver
Anpassung of Parameter ID "Taskclass" to DPS stream
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.3.0:

ID: 324125
Default settings in bus controller model corrected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 324390 / Support ID: 400104680
Correct functionality on SG3 CPU's
Channel description changed: Yes
Configuration description changed: No
Firmware changed:No

ID: 327660
Enhancement english online-help
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.1.3:

ID: 243085
Support X20AI2438
Enhancement DTM interface
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 316025
Corretions for AS4 DTM
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(86)

Version 1.0.0.2:

ID: 243085
Support X20AI2438
German online help added
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(83)

Version 1.0.0.0:

ID: 243085
Support X20AI2438
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_2.fw(81), 1\45993_1.fw(40)
Verze Jazyk
Operační systém
Datum
Velikost
Typ Stáhnout
1.1.0.0 * 09.01.2018 3 MB EXE AS2.6_HW_X20AI2438.exe
Popis V2.7 HW Upgrade (X20AI2438)

Revision information X20AI2438

Version 1.1.0.0:

ID: 562740 / Support ID: 400231500
Improved reset behavior
In rare cases, analog value measurement does not start after a reset.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 571600
Module documentation revised
Data sheet V1.24
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(100), 1\45993_2.fw(100)

Version 1.0.8.1:

ID: 536345
Module documentation revised
Data sheet V1.21
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.8.0:

ID: 519095
De-/Activation of subtitution mode revised
Thefeature "subtitution mode" can be deactivated completely.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 529665
Module documentation revised
Data sheet V 1.20
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.7.0:

ID: 464800
Ecad data (EPlan) corrected
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 466820
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 476495
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 497215
Module documentation revised
Data sheet V 1.11
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.6.5:

ID: 466820
Support for module DTM revised
The user defined item designation is shown in livelist of module (required AR: B4.25 or higher)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 476495
DTM diagnose revised
DTM diagnosis function can be used on cyclic data transfer as well.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 497215
Module documentation revised
Data sheet V1.10
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.6.0:

ID: 434345
Correction hwx/hwc
wrong MaxInSize-declaration
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.4.2:

ID: 402900 / Support ID: 400142019
Multiplexed mode revised
FIO datapionts for multiplexed mode corrected.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.4.0:

ID:366205
Compilation of homogeneous Channel Description/Channels section
Module family: "HART" (20Ax243x)

- Adaption of Descriptions and order of registers (IO-Mapping)
- Adaption of asynchronous HART communication
--> Asynchronous request of data points PvSampleTime adapted to documentation.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 368295
Parameter ID adapted to DPS driver
Anpassung of Parameter ID "Taskclass" to DPS stream
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.3.1:

ID: 366205
Compilation of homogeneous Channel Description/Channels section
Module family: "HART" (20Ax243x)

- Adaption of Descriptions and order of registers (IO-Mapping)
- Adaption of asynchronous HART communication
--> Asynchronous request of data points PvSampleTime adapted to documentation.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 368295
Parameter ID adapted to DPS driver
Anpassung of Parameter ID "Taskclass" to DPS stream
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.3.0:

ID: 324125
Default settings in bus controller model corrected
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 324390 / Support ID: 400104680
Correct functionality onSG3 CPU's
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 327660
Enhancement english online-help
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(90)

Version 1.0.1.3:

ID: 243085
Support X20AI2438
Enhancement DTM interface
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes

ID: 316025
Corretions for AS4 DTM
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(86)

Version 1.0.0.2:

ID: 243085
Support X20AI2438
German online help added
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_1.fw(40), 1\45993_2.fw(83)

Version 1.0.0.0:

ID: 243085
Support X20AI2438
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\45993_2.fw(81), 1\45993_1.fw(40)