DWL@DWL10000088867
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
1.8.0.0 | * | 12.04.2016 | 5 MB | EXE | AS2.6_HW_80SD100XS.C04X-13.exe | |
Popis |
V2.7 HW Upgrade (80SD100XS.C04X-13) Revision information 80SD100XS.C04X-13 Version 1.8.0.0: ID: 474115 Error correction in order to guard motor outputs against short to ground Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_2.fw(106), 1\42882_3.fw(106), 1\42882_4.fw(106), 1\42882_5.fw(106) Version 1.7.0.0: ID: 400865 Cycle time of MPGen edjustable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 400915 Function model Ramp: new mode Mode -120: Set home position Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 401000 Corrected a problem in HWX file Channel description changed: No Configuration description changed: No Firmwarechanged: No ID: 441035 / Support ID: 400133806 Corrected HWC entry Channel description changed: No Configuration description changed: No Firmware changed: No ID: 441040 Support for HW-Variant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_2.fw(104), 1\42882_3.fw(104), 1\42882_4.fw(104) Version 1.5.1.0: ID: 319025 Module bootup timeout configured Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 320790 Accelerated firmware update. Allows reliable firmware update behindCANIO bus controllers. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_2.fw(9), 1\42882_3.fw(9) Version 1.5.0.0: ID: 288440 / Support ID: 400084530 Encoder position should be displayed at PosVal03, if SDC information is setto "on" Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 301460 Support for HW-Variant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_2.fw(8), 1\42882_3.fw(8) Version 1.4.3.0: ID: 296385 / SupportID: 400087355 80SD100XS.C04X-13: Erroneous Detection of Short Circuit between Motor-Phaseand Ground Due to a Firmware-Error the activation of the Controller could be blocked under certain circumstances because of a wronglyassumed Short Circuit to Ground Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_2.fw(8) Version 1.4.2.0: ID: 290320 / Support ID: 400082483 In rare cases ACOPOSmicro generated an erroneous status indication (UZKStatus = not OK). Also high motor currents in conjunction with tolerances of electronic components could lead to module internal disturbances which in consequence could generate error messages. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42882_2.fw(7) Version 1.4.1.0: ID: 272460 / Support ID: 400049998 Module in undefined state, if no trigger happens in mode -121 (Remaining distance mode) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 272465 / Support ID: 400051695 The ACOPOSMicro doesn't switch in switched onwith a customer motor at ramp mode Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 272470 Ramp mode: Wrong configuratin for referencing speed is possible Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\42882_2.fw(6) Version 1.3.0.2: ID: 245880 Customer-specific expansion of hardware description file This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\42882_2.fw(5) Version 1.3.0.1: ID: 243380 Customer-specific expansion of hardware description file This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42882_2.fw(5) Version 1.2.0.0: ID: 230710 SDC support for the module 80SD100XS.C04X-01 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42882_2.fw(5) |