DWL@DWL10000878195
| Sürüm | Dil | İşletim sistemi | Tarih | Boyut | Tip | İndirme |
|---|---|---|---|---|---|---|
| 1.6.1.1 | * | 10/06/2026 | 779 KB | EXE | AS6_HW_X20DI8371.exe | |
| Açıklama |
V6.0 HW Upgrade (X20DI8371) Revision information X20DI8371 Version 1.6.1.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.0.0: ID: 767670 Failure ModulOK If this module starting with revision D0 is operated behind a bus controller, the network status fails every 10 s (for one X2X cycle). This failure has the following effects. - Local X2X bus: No effect - POWERLINK / Modbus TCP / PROFIBUS / CAN I/O: No effect - CANopen: "Object 0x30B2 Network status OK" fails sporadically. - OPC-UA: Flag ModuleOK of the respective X2X module may fail sporadically - EthernetIP / PROFINET / Sercos3 / EtherCAT: - No effect directly on the bus controller. - The network status is transferred asBYTE at the beginning of the cyclic data of the respective X2X station (ModuleOK) and can be evaluated by the respective remote station (data point mappingand evaluation within the application). - Setpoint: 0xF5, in the event of error: 0xF1 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 767675 Setting "Allow unbalanced on/off variable" can result in a cyclic failure of the modulestarting with revision D0. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42155_10.fw(230), 1\42155_12.fw(230), 1\42155_20.fw(220), 1\42155_22.fw(230), 1\42155_5.fw(784) Version 1.4.0.0: ID: 740275 Support new HW variant 20 Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\42155_10.fw(200), 1\42155_20.fw(220), 1\42155_5.fw(784) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: 721725 Support new HW-variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 722740 Module documentation revised Data sheet V3.07 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42155_10.fw(200), 1\42155_5.fw(784) Version 1.1.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.2.0: ID: 456910 Module documentation revised Datasheet V3.02 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42155_5.fw(784) Version 1.0.1.2: ID: 405760 Enhancements packed data point for inputs Channeldescription changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\42155_5.fw(784) Version 1.0.1.0: ID: 218905 Module addressing corrected on SG3 CanIo Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42155_5.fw(784) Version 1.0.0.0: ID: 171235 First revision Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42155_5.fw(784) |
|||||