General information
Certifications
CE Yes
UKCA Yes
CRA (Cyber Resilience Act) Non-compliant
Functional safety Yes
UL cULus E225616
Power conversion equipment
KC Yes
Note Variant with partially coated printed circuit boards
B&R ID code 0xA09C
Slots for plug-in modules 4
Mains connection
Permissible network configurations TT, TN
Mains input voltage 3x 400 VAC to 480 VAC ±10%
Frequency 50 / 60 Hz ±4%
Installed load Max. 54 kVA
Inrush current at 400 VAC 26 A
Switch-on interval >10 s
Integrated line filter per EN 61800-3, category C3 Yes
Power dissipation at device nominal power without braking resistor Approx. 1600 W
DC bus connection
DC bus capacitance 3300 µF
24 VDC power supply
Current consumption at 24 VDC
Mains input voltage applied -
Mains input voltage not applied Max. 4.6 A + 1.4 * (Current for motor holding brake + Current on 24 VDC output)
DC bus power supply unit
Switch-on voltage 455 VDC
Input voltage 24 VDC +25% / -20%
Input capacitance 32,800 µF
24 VDC output
Output voltage
Mains input voltage applied 22 to 24 VDC
Mains input voltage not applied 16.7 to 30 VDC
Output current Max. 0.5 A
Motor connection
Reduction of continuous current depending on ambient temperature
Mains input voltage: 400 VAC
Switching frequency 5 kHz No reduction
Switching frequency 10 kHz No reduction
Switching frequency 20 kHz 0.96 Aeff per °C (starting at 25°C)
Mains input voltage: 480 VAC
Switching frequency 5 kHz No reduction
Switching frequency 10 kHz 0.96 Aeff per °C (starting at 50°C)
Switching frequency 20 kHz 0.96 Aeff per °C (starting at 10°C)
Reduction of continuous current depending on installation elevation
Starting at 500 m above sea level 6.4 Aeff per 1000 m
Protective measures
Overload protection Yes
Short-circuit and ground fault protection Yes
Terminal connection cross section
Flexible and fine-stranded wires
With wire end sleeve 10 to 35 mm²
Approbation data
UL/C-UL-US 10 to 2 AWG
CSA 10 to 2 AWG
Quantity 1
Continuous current 64 Aeff
Peak current 200 Aeff
Nominal switching frequency 10 kHz
Possible switching frequencies 5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004 Limit value curve A
Max. motor line length 25 m
Max. output frequency 598 Hz
Motor holding brake connection
Response threshold for open-circuit monitoring Approx. 210 mA
Max. output current 3 A
Max. number of switching cycles Approx. 80,000
Braking resistor
Peak power int./ext. 7 / 250 kW
Continuous power int./ext. 0.2 / 24 kW
Minimum braking resistance (ext.) 2.5 Ω
Rated current of built-in fuse 30 A (fast-acting)
Limit switch and reference inputs
Electrical isolation
Input - ACOPOS Yes
Input - Input No
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Switching threshold
Low <5 V
High >15 V
Quantity 3
Circuit Sink
Input current at nominal voltage Approx. 4 mA
Switching delay Max. 2.0 ms
Modulation compared to ground potential Max. ±38 V
Enable inputs
Electrical isolation
Input - ACOPOS Yes
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Switching threshold
Low <5 V
High >15 V
Switching delay
Enable 0 → 1, ready for PWM Max. 100 µs
Enable 1 → 0, PWM off Max. 2.0 ms
Quantity 1
Circuit Sink
Input current at nominal voltage Approx. 30 mA
Modulation compared to ground potential Max. ±38 V
OSSD signal connections Not permitted
Trigger inputs
Electrical isolation
Input - ACOPOS Yes
Input - Input No
Input voltage
Nominal 24 VDC
Maximum 30 VDC
Switching threshold
Low <5 V
High >15 V
Switching delay
Rising edge 52 µs ±0.5 µs (digitally filtered)
Falling edge 53 µs ±0.5 µs (digitally filtered)
Quantity 2
Circuit Sink
Input current at nominal voltage Approx. 10 mA
Modulation compared to ground potential Max. ±38 V
Electrical properties
Energy efficiency (IE classification)
Power dissipation relative to continuous apparent power IE2 (10,25) 0.9%
IE2 (50,25) 0.9%
IE2 (10,50) 1.1%
IE2 (50,50) 1.2%
IE2 (90,50) 1.3%
IE2 (10,100) 1.7%
IE2 (50,100) 2%
IE2 (90,100) 2.3%
Nominal losses in standby mode 32 W
Discharge capacitance 5.4 µF
Operating conditions
Permissible mounting orientations
Hanging vertically Yes
Horizontal, face up Yes
Standing horizontally No
Installation elevation above sea level
Nominal 0 to 500 m
Maximum 2000 m
Pollution degree per EN 61800-5-1 2 (non-conductive pollution)
Overvoltage category per EN 61800-5-1 II
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature
Operation
Nominal 5 to 40°C
Maximum 55°C
Storage -25 to 55°C
Transport -25 to 70°C
Relative humidity
Operation 5 to 85%
Storage 5 to 95%
Transport Max. 95% at 40°C
Mechanical properties
Dimensions
Width 276 mm
Height 460 mm
Depth 295 mm
Weight 24.1 kg
Номер модель:
8V1640.001-2
Описание:
  • Modular mechanical design using plug-in modules
  • Integrated line filter
  • Integrated or optional external braking resistor
  • Integrated electronic restart inhibit
  • Partially-coated circuit boards - more robust in regard to environmental influences (8Vxxxx.001-2)
ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
Включено в комплект поставки
Shield component sets
8X0030.00-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
Terminal block sets
8X0005.00-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
Дополнительные аксессуары
Braking resistors
8B0W0045H000.001-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8B0W0079H000.000-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8B0W0079H000.001-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
Plug-in modules
8AC110.60-3 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC114.60-2 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC120.60-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC121.60-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC122.60-3 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC123.60-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC125.60-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC125.60-2 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC125.61-2 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC126.60-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC130.60-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
8AC131.60-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
Undefined
8B0W0045H000.000-1 ACOPOS servo drive, 3x 400-480 V, 64 A, 32 kW, coated, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock
E-CAD (Electro или EPLAN шаблоны) Версия (Дата) Загрузка
ACOPOS EPLAN P8 from V2.4 EXE / 23 МБ
M-CAD (Механические Шаблоны Версия (Дата) Загрузка
3D file STEP ACOPOS 1640 ZIP / 3 МБ
Документация Версия (Дата) Загрузка
ACOPOS User´s Manual PDF / 49 МБ
Datasheet 8V1640.00-2 PDF / 4 МБ
Datasheet 8V1640.001-2 PDF / 4 МБ
Safety Guidelines PDF / 1 МБ
Инструменты / Утилиты / Примеры Версия (Дата) Загрузка
Sistema (VDMA) library ZIP / 5 кБ
Обновление Automation Studio HW Версия (Дата) Загрузка
V4.0 HW Upgrade (8V1640.001-2) EXE / 301 кБ
V6.0 HW Upgrade (8V1640.001-2) EXE / 374 кБ
Сертификаты Версия (Дата) Загрузка
ACOPOS KC certificates ZIP / 601 кБ
E225616 UL Certificate of Compliance ACOPOS PDF / 242 кБ
EU Declaration FS Servos ACOPOS PDF / 678 кБ
EU Declaration Servos ACOPOS PDF / 271 кБ
TÜV-certificate - function "Safe Pulse Disabling" ZIP / 423 кБ
UK Declaration FS Servos ACOPOS PDF / 89 кБ
UK Declaration Servos ACOPOS PDF / 109 кБ

Укажите страну и язык