DWL@DWL10000829574

Версия Язык
Операционная система
Дата
Размер
Тип Загрузка
1.02 * 15.10.2025 5 МБ ZIP UPG_xPC3200_MTCX_V0102_EFI.zip
Описание xPC3200 Firmware Upgrade (MTCX and SDL4T)

----------------------------------------------------------------
ATTENTION! Possible upgrade problems and version dependency
----------------------------------------------------------------

1. Do not reset or switch off the device during the upgrade
process !!!

2. If a UPS is connected to the system, the battery unit must be
disconnected or the Power button must be pressed (to set the
system in standby mode) after the upgrade is done, but before
the required Power Off/On is done. Otherwise the firmware
upgrade is not complete, because the UPS will provide the
system with power.

3. A Extended upgrade for the SDL4T Firmware is only necessary
if an SDL4T firmware less than V01.00 is installed.

4. Starting with SDL4T Firmware V01.00, a downgrade to a version
smaller then V01.00 is not possible.

5. Starting with SDL4T Firmware V01.00, a Automation Panel
Firmware update for the SDL4R Firmware at least from V06.14
and HDBT Firmware at least from V01.00 is necessary.

----------------------------------------------------------------
Version 01.02 / 09/29/2025 / MIK !MANDATORY UPDATE!
----------------------------------------------------------------

Content
LIESMICH.txt 01.02 NEW
README.txt 01.02 NEW
STARTUP.nsh 01.00
MTCXxPC3200.nsh 01.00
SDL4TxPC3200.nsh 01.00
MTCXSVC.efi 22.02
11411_0.fw 01.02 NEW
11412_0.fw 01.02 NEW
11413_0.fw 01.02 NEW
11414_0.fw 01.02 NEW
11415_0.fw 01.02 NEW
11426_0.fw 01.02 NEW
11427_0.fw 01.02 NEW
11428_0.fw 01.02 NEW
60620_0.fp (SDL4T) 01.04
60620i0.fp (SDL4TExt.) 01.04

Change(s)

61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw,
61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware):
- Bugfix: a special custom panel did not work in combination
with a PPC3200.

ATTENTION!
Possible upgrade problems and version dependency, see above.
Версия Язык
Операционная система
Дата
Размер
Тип Загрузка
1.01 * 26.08.2025 5 МБ ZIP UPG_xPC3200_MTCX_V0101_EFI.zip
Описание xPC3200 Firmware Upgrade (MTCX and SDL4T)

----------------------------------------------------------------
ATTENTION! Possible upgrade problems and version dependency
----------------------------------------------------------------

1. Do not reset or switch off the device during the upgrade
process !!!

2. If a UPS is connected to the system, the battery unit must be
disconnected or the Power button must be pressed (to set the
system in standby mode) after the upgrade is done, but before
the required Power Off/On is done. Otherwise the firmware
upgrade is not complete, because the UPS will provide the
system with power.

3. A Extended upgrade for the SDL4T Firmware is only necessary
if an SDL4T firmware less than V01.00 is installed.

4. Starting with SDL4T Firmware V01.00, a downgrade to a version
smaller then V01.00 is not possible.

5. Starting with SDL4T Firmware V01.00, a Automation Panel
Firmware update for the SDL4R Firmware at least from V06.14
and HDBT Firmware at least from V01.00 is necessary.

----------------------------------------------------------------
Version 01.01 / 02/07/2025 / MIK !MANDATORY UPDATE!
----------------------------------------------------------------

Content
LIESMICH.txt 01.01 NEW
README.txt 01.01 NEW
STARTUP.nsh 01.00
MTCXxPC3200.nsh 01.00
SDL4TxPC3200.nsh 01.00
MTCXSVC.efi 22.02
11411_0.fw 01.01 NEW
11412_0.fw 01.01 NEW
11413_0.fw 01.01 NEW
11414_0.fw 01.01 NEW
11415_0.fw 01.01 NEW
11426_0.fw 01.01 NEW
11427_0.fw 01.01 NEW
11428_0.fw 01.01 NEW
60620_0.fp (SDL4T) 01.04
60620i0.fp (SDL4TExt.) 01.04

Change(s)

61320_0.fw, 61321_0.fw, 61322_0.fw, 61333_0.fw, 61334_0.fw,
61335_0.fw, 61336_0.fw, 61337_0.fw (MTCX Firmware):
- Bugfix: when using PLK IF cards in the SL2 and CAN IF cards in
the SL1, the PLK did not work.

ATTENTION!
Possible upgrade problems and version dependency, see above.
Loading