DWL@DWL10000878085
| Versão | Idiomas | Sistema operacional | Data | Tamanho | Tipos | Download |
|---|---|---|---|---|---|---|
| 1.8.0.1 | * | 10/06/2026 | 966 KB | EXE | AS6_HW_X20cDO4332.exe | |
| Descrição |
V6.0 HW Upgrade (X20cDO4332) Revision information X20cDO4332 Version 1.8.0.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel descriptionchanged: no Configuration description changed: yes Firmware changed: no Version 1.8.0.0: ID: 775560 Support new HW variant 20 Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\57895_10.fw(250), 1\57895_11.fw(250), 1\57895_20.fw(250), 1\57895_5.fw(816) Version 1.7.0.0: ID: 766275 Failure ModulOK If this module starting with revision I0is operated behind a bus controller, the network status fails every 10 s (forone X2X cycle). This failure has thefollowing effects. - Local X2X bus: No effect - POWERLINK / Modbus TCP / PROFIBUS / CAN I/O: No effect - CANopen: "Object 0x30B2 Network status OK" fails sporadically. - OPC-UA: Flag ModuleOK of the respective X2X module may fail sporadically - EthernetIP / PROFINET / Sercos3 / EtherCAT: - No effect directly on the bus controller. - The network status is transferred as BYTE at the beginning of the cyclicdata of the respective X2X station (ModuleOK) and can be evaluated by the respective remote station (data point mapping and evaluation within the application). - Setpoint: 0xF5, in the event of error: 0xF1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57895_10.fw(220), 1\57895_11.fw(220), 1\57895_5.fw(816) Version 1.6.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.5.0.0: ID: 676720 Adaptation framework for fast cycles for hardware variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 702290 Support hardware variant 11 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 702300 Module documentation revised Data sheet V 3.26 Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\57895_10.fw(190), 1\57895_11.fw(190), 1\57895_5.fw(816) Version 1.3.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.2.0.0: ID: 647530 Performance optimization of X2X communication Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57895_10.fw(150), 1\57895_5.fw(816) Version 1.1.0.0: ID: 626715 Support hardware variant 10 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 626725 Module documentation revised Data sheet V 3.25 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57895_10.fw(130), 1\57895_5.fw(816) Version 1.0.3.0: ID: 469110 Module documentation revised Data sheet V 3.22 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57895_5.fw(816) Version 1.0.0.0: ID: 343820 Support X20cDO4332 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57895_5.fw(816) |
|||||