V4.3 HW Upgrade (5PPC3100.KBU1-000)

DWL@DWL10000532110

Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.3.1.0 * 02/07/2025 934 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000

Version 2.3.1.0:

ID: AQAJ-9507
New MTCX V4.28 for PPC3100 with following changes:
- Bugfix: when using PLK IF cards in the SL2 and CAN IF cards in
the SL1, the PLK did not work.
- Bugfix: Slight image distortions occurred sporadically and in
very rare cases on the PPC3100 when used with SXGA displays.
The default "PLLRange" value of the DPtoLVDS bridge has been
adjusted, and this can also be adjusted starting with BIOS V1.46.
- Bugfix: When using four SDL4 panels (with SDL4 Converter Box)
and a special customer-specific panel variant, problems occurred
on the last panel of the SDL4 converter (e.g., the backlight of
this panel could not be adjusted).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(428)

Version 2.3.0.0:

ID: AQAJ-8596
Support for 5AC901.ICAN-01
Support for 5AC901.ICAN-01 starting with:
- AS 4.12.7 andAR L4.93
- AS 6.1.1 and AR 6.1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware:1\61320_0.fw(427)

Version 2.2.7.0:

ID: 781665
New MTCX version V04.27
New MTCX version V04.27 with following changes.
- Bugfix: if a SDL3 Converter Box is installed on the onboard
SDL interface, sporadic problems (slow response rate) of the
ADI Control Center could occur.
This behavior could only be observed with MTCX V4.26.
- Bugfix: Display timings on PPC3100. Some display combinations
could lead to image disturbances when changing the graphics
modes or when activating/deactivating the screen saver.
This behavior became more common observed with a 12.1in XGA
display. The Power off/on and backlight off/on timings have
been optimized.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(427)

Version 2.2.6.0:

ID: 773110
New MTCX version V04.26
New MTCX version V04.26 with following changes:
- Optimized internal power supply.
- Optimized SDL link timing.
- Optimized PowerOff/On/Standby handling for Hypervisor systems.
- Support of alternative/new temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(426)

Version 2.2.5.0:

ID: 756230
New MTCX version V04.25
New MTCX version V04.25 with following changes.
- Optimized internal power supply.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(425)

Version 2.2.4.0:

ID: 752930
Bugfix: Support for PTP (ETH2 only) starting withAS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.3.0:

ID: 749065
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.2.0:

ID: 742320
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24with following changes.
- Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface incombination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + ARA4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for allcomponents (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX versionV04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware:1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX versionV04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID:585445
First version
The Panel PC 3100 is supported with AutomationStudio Version V4.3.4. As operating system it is mandatory to use the versionE4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.3.0.0 * 04/02/2025 933 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000

Version 2.3.0.0:

ID: AQAJ-8596
Support for 5AC901.ICAN-01
Support for 5AC901.ICAN-01 starting with:
- AS 4.12.7 and AR L4.93
- AS 6.1.1 and AR 6.1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(427)

Version 2.2.7.0:

ID: 781665
New MTCX version V04.27
New MTCX version V04.27 with following changes.
- Bugfix: if a SDL3 Converter Box is installed on the onboard
SDL interface, sporadic problems (slow response rate) of the
ADI Control Center could occur.
This behavior could only be observed with MTCX V4.26.
- Bugfix: Display timings on PPC3100. Some display combinations
could lead to image disturbances when changing the graphics
modes or when activating/deactivating the screen saver.
This behavior became more common observed with a 12.1in XGA
display. The Power off/on and backlight off/on timings have
been optimized.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(427)

Version 2.2.6.0:

ID: 773110
New MTCX version V04.26
New MTCXversion V04.26 with following changes:
- Optimized internal power supply.
- Optimized SDL link timing.
- Optimized PowerOff/On/Standby handling for Hypervisor systems.
- Support of alternative/new temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(426)

Version 2.2.5.0:

ID: 756230
New MTCX version V04.25
New MTCX version V04.25 with following changes.
- Optimized internal power supply.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(425)

Version 2.2.4.0:

ID: 752930
Bugfix: Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.3.0:

ID: 749065
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.2.0:

ID: 742320
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24 with following changes.
- Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-SlotSL3 of the PPC3100 can only be used for interface cards from AS 4.9 + AR A4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID:658770
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistivesingle touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID:595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation StudioVersion V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the PanelPC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0.For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.7.0 * 17/04/2024 933 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000

Version 2.2.7.0:

ID: 781665
New MTCX version V04.27
New MTCX version V04.27 with following changes.
- Bugfix: if a SDL3 Converter Box is installed on the onboard
SDL interface, sporadic problems(slow response rate) of the
ADI Control Center could occur.
This behavior could only be observed with MTCX V4.26.
- Bugfix: Display timings onPPC3100. Some display combinations
could lead to image disturbances whenchanging the graphics
modes or when activating/deactivating the screen saver.
This behavior became more common observed with a 12.1in XGA
display. The Power off/on and backlight off/on timings have
been optimized.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(427)

Version 2.2.6.0:

ID: 773110
New MTCX version V04.26
New MTCX version V04.26 with following changes:
- Optimized internal power supply.
- Optimized SDL link timing.
- Optimized PowerOff/On/Standby handling for Hypervisor systems.
- Support of alternative/new temperature sensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(426)

Version 2.2.5.0:

ID: 756230
New MTCX version V04.25
New MTCX version V04.25 with following changes.
- Optimized internal power supply.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(425)

Version 2.2.4.0:

ID: 752930
Bugfix: Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.3.0:

ID: 749065
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version2.2.2.0:

ID: 742320 / Support ID: 400365944
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24 with following changes.
- Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen onPPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards fromAS 4.9 + AR A4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgradesis not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisortarget systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support forIF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with followingchanges.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occursin combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: batterystate implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* haveto be used mandatory in the version V1.2.0.0. For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.6.0 * 08/09/2023 933 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000

Version 2.2.6.0:

ID: 773110
New MTCX version V04.26
New MTCX version V04.26 with following changes:
- Optimized internal power supply.
- Optimized SDL link timing.
- Optimized PowerOff/On/Standby handling for Hypervisor systems.
- Support of alternative/new temperaturesensors.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(426)

Version 2.2.5.0:

ID: 756230
New MTCX version V04.25
New MTCX version V04.25 with following changes.
- Optimized internal power supply.
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes
Firmware: 1\61320_0.fw(425)

Version2.2.4.0:

ID: 752930
Bugfix: Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.3.0:

ID: 749065
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.2.0:

ID: 742320 / Support ID: 400365944
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24 with following changes.
- Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + ARA4.90. The IF-Slot has no function with olderAS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX versionV04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware:1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Startingwith Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix -Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Componentsthe minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.5.0 * 14/09/2022 617 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000

Version 2.2.5.0:

ID: 756230
New MTCX version V04.25
New MTCX version V04.25 with following changes.
- Optimized internal power supply.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(425)

Version 2.2.4.0:

ID: 752930
Bugfix: Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.3.0:

ID: 749065
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.2.0:

ID: 742320 / Support ID: 400365944
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24 with following changes.
- Bugfix:in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + ARA4.90. The IF-Slot has no functionwith older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.Thisrequires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of thecurrent and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal powersupply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Componentsthe minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.4.0 * 10/06/2022 622 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000

Version 2.2.4.0:

ID: 752930
Bugfix: Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware:1\61320_0.fw(424)

Version 2.2.3.0:

ID: 749065
Support for PTP (ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.2.0:

ID: 742320 / SupportID: 400365944
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPCUA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
NewMTCX version V04.24
New MTCX version V04.24 with following changes.
-Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 isoperated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + AR A4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channeldescription changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from ARA4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of thishardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX versionV04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID:585445
First version
The Panel PC 3100 is supported with AutomationStudio Version V4.3.4. As operating system it is mandatory to use the versionE4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.3.0 * 03/05/2022 622 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000.KBU0-000

Version 2.2.3.0:

ID: 749065
Support for PTP(ETH2 only) starting with AS V4.12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.2.0:

ID: 742320 / Support ID: 400365944
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCXversion V04.24
New MTCX version V04.24 with following changes.
- Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + ARA4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmwarechanged: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Supportfor IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed:No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for theusage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of theAutomation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix forthe ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed:No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the displayunits 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.2.0 * 10/02/2022 622 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000.KBU0-000

Version 2.2.2.0:

ID: 742320 / Support ID: 400365944
If Linux should be restarted separately from AR on a PPC3100 hypervisor system, Linux no longer boots and the system must be restarted as a whole.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24 with following changes.
- Bugfix: invery rare cases, short sporadic display flickering can occur.
Until nowthis effect is only seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + ARA4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCXversion V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description filethe 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usageof the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. ForVisual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.1.0 * 21/12/2020 619 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU1-000.KBU1-000

Version 2.2.1.0:

ID: 711290
Preparation forhyperthreading expansions in the B&R Hypervisor from AS 4.10.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61321_0.fw(424)

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24 with following changes.
- Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect isonly seen on PPC3100.
APC3100 system is not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + ARA4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61321_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDMis displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that theappropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and olderHWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61321_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61321_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 inB&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61321_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61321_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61321_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch paneland MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61321_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. Asoperating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the PanelPC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61321_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.0.0 * 30/07/2020 619 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 2.2.0.0:

ID: 685420
Preparation for the support of OPC UA TSN from AS 4.9.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 687455
New MTCX version V04.24
New MTCX version V04.24 with following changes.
- Bugfix: in very rare cases, short sporadic display flickering can occur.
Until now this effect is only seen on PPC3100.
APC3100 systemis not affected.
- Optimization of the SDL interface in combination with DVI panels.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 691555
Preparation for the support for 5ACCIF04.FPLK-000 from AS 4.9/AR A4.90.
The 5ACCIF04.FPLK-000 is operated in the IF-Slot SL3 of the PPC3100. The IF-Slot SL3 of the PPC3100 can only be used for interface cards from AS 4.9 + ARA4.90. The IF-Slot has no function with older AS/AR versions.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(424)

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID:677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IFoption 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate andjumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Componentsthe minimum version VC4.34.1 has to beused.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.1.0.0 * 31/03/2020 629 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 2.1.0.0:

ID: 658770 / Support ID: 400297557
Bugfix: SDM is displaying "wrong" CPU temperature.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665440
Wear level of storage medium from AR A4.90:
Additional data point to display the wear level in %.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 665445
Extensions Hypervisor from AR A4.81
USB allocation between GPOS and RTOS also possible on the Automation Panel.This requires that the appropriate hardware upgrades are used for all components (APC/PPC, AP, SDLx Receiver, SDLx Transmitter).
Starting with AS 4.8 following HWX upgrades (or newer) are recommended for PPC3100, mixed operation of the current and older HWX upgrades is not recommended:
PPC3100 system unit: V2.1.0.0
AP1000 panels: V2.0.0.0
AP9x3 panels: V2.0.0.0
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 673905 / Support ID: 400297541
Bugfix for 'TemperatureCPU'
Sporadic problems with the IO datapoint 'TemperatureCPU' are solved within the MTCX version V4.22. It's part of this hardware upgrade version.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 677065
New MTCX version V04.22
New MTCX version V04.22 with following changes.
- Bugfix: Sporadically the CPU temperature showed invalid values.
- Support for IF option 5ACCIF04.FPLK-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\61320_0.fw(422)

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supplysyncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the5AC901.ISRM-00 is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOSis restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio VersionV4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the PanelPC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.0.3.0 * 13/05/2019 579 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 2.0.3.0:

ID: 644370
Soft reset support for hypervisor target systems.
From version AR 4.71 an independent reboot of AR and GPOS is possible.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00is now correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 /Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&RHypervisor
Is at least the version A4.53 of the Automation Runtime embedded in usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
-Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel andMTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the PanelPC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Components the minimum version VC4.34.1 has to be used.
Channel description changed:Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.0.2.0 * 19/04/2019 691 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 2.0.2.0:

ID: 634010
New MTCX version V04.21
New MTCX version V04.21 with following changes.
- Optimized internal keyboard syncronization.
- Optimized internal power supply syncronization.
- Optimized MTCX IRQ support.
- Optimized NMI syncronization.
- Support for IF option 5ACCIF02.ISS0-000 implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 634020 / Support ID: 400275422
Support of 5AC901.ISRM-00 in ARwin
With a bugfix in the hardware description file the 5AC901.ISRM-00 isnow correctly detected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 640795 / Support ID: 400271965, 400275569
Bugfix for the usage of the ETH2 in B&R Hypervisor
Is at least the version A4.53 of the Automation Runtime embeddedin usage, the ETH2 works fine in the GPOS, even if the GPOS is restarted.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(421)

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmwarechanged: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Components theminimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.0.1.0 * 05/12/2018 693 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 2.0.1.0:

ID: 620085
New MTCX version V04.20
New MTCX version V04.20 with following changes.
- Bugfix: serial COMPort (FIFO).
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 621260
Bugfix for the ETHinternal interface
ModbusTCP and OPC UA are working now for the ETHinternal.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(420)

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Componentsthe minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.0.0.0 * 30/10/2018 659 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 2.0.0.0:

ID: 601485
New MTCX version V04.19
New MTCX version V04.19 with following changes.
- Support for IF option 5AC901.I232-00 implemented.
- Support for USB standby PowerOn switch implemented.
- MTCX communication interface IRQ support implemented.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 602130
Preperation to support the B&R Hypervisor
- Starting with Automation Studio V4.4.5 and Automation Runtime B4.45 or D4.51.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\61320_0.fw(419)

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100 and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmwarechanged: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Componentsthe minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed:Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
1.0.2.0 * 29/06/2018 649 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 1.0.2.0:

ID: 594270
New MTCX version V04.18
New MTCX version V04.18 with following changes.
- Enhancements for B&R Hypervisor.
- Bugfix - Customer Panel Interface A.
Inaccurate and jumping touch service.
Problem only occurs in combination with a PPC3100and a resistive single touch panel and MTCX V04.16.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 595590
IO Mapping: battery state implemented
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\61320_0.fw(418)

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Componentsthe minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
1.0.1.0 * 14/03/2018 646 KB EXE AS4_HW_5PPC3100.KBU1-000.exe
Opis V4.3 HW Upgrade (5PPC3100.KBU1-000)

Revision information 5PPC3100.KBU0-000

Version 1.0.1.0:

ID: 585445
First version
The Panel PC 3100 is supported with Automation Studio Version V4.3.4. As operating system it is mandatory to use the version E4.34 of the Automation Runtime Embedded or the Automation Runtime Windows. To be able to project the Panel PC 3100 correctly it is mandatory to use the display units 5AP9* in the version V1.6.0.0 and the 5AP1* in the version V1.2.0.0. The interface options 5AC901.I* have to be used mandatory in the version V1.2.0.0. For Visual Componentsthe minimum version VC4.34.1 has to be used.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\61320_0.fw(415)
Loading
Powrót do listy