V4.0 HW Upgrade (8EI8X8MWT10.0100-1)

DWL@DWL10000408297

Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.4.0.0 * 23/09/2025 553 KB EXE AS4_HW_8EI8X8MWT10.0100-1.exe
Opis V4.0 HW Upgrade (8EI8X8MWT10.0100-1)

Revision information 8EI8X8MWT10.0100-1

Version 2.4.0.0:

ID: UNNW-4572
New function: Support of EnDat 3 encoders
Support of the encoder interface 'EnDat 3'.

Minimum versions:
-TP ACP10/ARNC0 Version 5.30.0/6.2.0 to support EnDat 3 encoders
-TP ACP10/ARNC0 Version 5.30.0/6.3.0 for the current AS help
-mapp Motion Version 5.30.0/6.2.0 to support EnDat 3 encoders
-Automation Studio Version AS 4.0.11.x/6.0.x to support EnDat 3 encoders
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.3.2.0:

ID: 728020
Wrong description for encoder connector in module configuration
For some modules the description of the encoderconnector was wrong.
The description of the encoder connector in the configuration in AS was not the same as on the housing of the module.

Added attribute "Label" for encoder connectors.

-Automation Studio version AS4.0.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

ID: 768625
Support of new ACP P3 modules 8EI*-2
The following modules are now supported:
8EI2X2HCT10.XXXX-2
8EI2X2HWT10.XXXX-2
8EI2X2MCT10.XXXX-2
8EI2X2MWT10.XXXX-2
8EI4X5HCT10.XXXX-2
8EI4X5HWT10.XXXX-2
8EI4X5MCT10.XXXX-2
8EI4X5MWT10.XXXX-2
8EI8X8HCT10.XXXX-2
8EI8X8HWT10.XXXX-2
8EI8X8MCT10.XXXX-2
8EI8X8MWT10.XXXX-2


-Automation Studio version AS 4.0.11
-mapp Motion version5.24
Channel description changed: no
Configuration description changed:yes
Firmware changed: no

Version 2.3.1.1:

ID: 707900
Correct display of the DC-Bus Voltage in the speed torque chart.
The DC bus voltage from the configuration of the module is adopted in the Speed ​​Torque Chart.
This function is supported from AS 4.10.
The following upgrades don´t support the Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.3.1.0:

ID: 446210
Support of Speed Torque Chart in Automation Studio for ACOPOS P3
Extension of the hardware upgrades to support the Speed Torque Chart for ACOPOS P3.
This function is supported from AS 4.10.
The following upgrades don´t supportthe Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.3.0.3:

ID: 699970
Added description "(PLK)" for attribute "Label" for Powerlink connectors
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

ID: 699975
Misconfiguration of mapp Motion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is notrecognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- Automation Studio V4.4.4
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

ID: 699980
Parameter "SdcEnabled" initialized incorrectly
Data type of parameter was changed to STRING and inital value to "off".
Channel description changed: no
Configuration description changed:yes
Firmware changed: no

ID: 699985
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

ID: 653390
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.3.0.2:

ID: 622565
Parameter "SdcEnabled" initialized incorrectly
Data type ofparameter was changed to STRING and inital value to "off".
Channel description changed: no
Configuration description changed: no
Firmware changed:no

Version 2.3.0.0:

ID: 600425
Misconfiguration of mapp Motion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is notrecognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- AutomationStudio V4.4.4
Channel description changed: no
Configuration descriptionchanged: no
Firmware changed: no

ID: 602480
Incorrect connector designation
Connector designation X41 was used instead of X43. Affected hardware: 8EI013HWS10.xxxx-1 and 8EI017HWS10.xxxx-1
Channel description changed: no
Configuration description changed: no
Firmware changed: no

Version 2.2.0.1:

ID: 593915
ACOPOS P3: Support for new hardware upgrades
The following ACOPOS P3 hardware can now be configured:
- 8EI013HWS10.xxxx-1
- 8EI013HWSS0.xxxx-1
- 8EI017HWD10.xxxx-1
- 8EI017HWDS0.xxxx-1
- 8EI017HWSS0.xxxx-1
- 8EI022HWDS0.xxxx-1
- 8EI024HWS10.xxxx-1
- 8EI024HWSS0.xxxx-1
- 8EI034HWS10.xxxx-1
- 8EI034HWSS0.xxxx-1
- 8EI044HWSS0.xxxx-1
- 8EI1X6HWS10.xxxx-1
- 8EI1X6HWSS0.xxxx-1
- 8EI1X6MWS10.xxxx-1
- 8EI1X6MWSS0.xxxx-1
- 8EI2X2HWD10.xxxx-1
- 8EI2X2HWDS0.xxxx-1
- 8EI2X2HWS10.xxxx-1
- 8EI2X2HWSS0.xxxx-1
- 8EI2X2HWT10.xxxx-1
- 8EI2X2HWTS0.xxxx-1
- 8EI2X2MWD10.xxxx-1
- 8EI2X2MWDS0.xxxx-1
- 8EI2X2MWS10.xxxx-1
- 8EI2X2MWSS0.xxxx-1
- 8EI2X2MWT10.xxxx-1
- 8EI2X2MWTS0.xxxx-1
- 8EI4X5HWD10.xxxx-1
- 8EI4X5HWDS0.xxxx-1
- 8EI4X5HWS10.xxxx-1
- 8EI4X5HWSS0.xxxx-1
- 8EI4X5HWT10.xxxx-1
- 8EI4X5HWTS0.xxxx-1
- 8EI4X5MWD10.xxxx-1
- 8EI4X5MWDS0.xxxx-1
- 8EI4X5MWS10.xxxx-1
- 8EI4X5MWSS0.xxxx-1
- 8EI4X5MWT10.xxxx-1
- 8EI4X5MWTS0.xxxx-1
- 8EI8X8HWD10.xxxx-1
- 8EI8X8HWDS0.xxxx-1
- 8EI8X8HWS10.xxxx-1
- 8EI8X8HWSS0.xxxx-1
- 8EI8X8HWT10.xxxx-1
- 8EI8X8HWTS0.xxxx-1
- 8EI8X8MWD10.xxxx-1
- 8EI8X8MWDS0.xxxx-1
- 8EI8X8MWS10.xxxx-1
- 8EI8X8MWSS0.xxxx-1
- 8EI8X8MWT10.xxxx-1
- 8EI8X8MWTS0.xxxx-1
Channel description changed: no
Configuration description changed: no
Firmware changed: no

Version 2.2.0.0:

ID: 549300
Support of motion system mapp Motion
HWX fileextended for usage with motion system mapp Motion.
Channel description changed: no
Configuration description changed: no
Firmware changed: no

Version 1.0.0.5:

ID: 523745
Encodertype added
Hiperface DSL isnow selectable in the encoderconfiguration of ACOPOS P3.
ACP10 Minimumversion 3.16.0
Channel description changed: no
Configuration description changed: no
Firmware changed: no

Version 1.0.0.4:

ID: 515600
Wrong display of ACOPOS P3 modules in SDM.
Informations of ACOPOS P3 plug-in module and ACOPOS P3 motors weren't shown.
Channel description changed: no
Configuration description changed: no
Firmware changed: no

Version 1.0.0.3:

ID: 476920
ACOPOS P3 with encoder setting BISS or SSI
With setting BISS or SSI an error in the ARCONFIG occured and errornumber 32225: "This ACOPOS POWERLINK node does not exist in the AR Configuration" was displayed.
Channel description changed: no
Configuration description changed: no
Firmware changed: no

Version 1.0.0.2:

ID: 462370
HW upgrade for support of BiSS, SSI and Technology Guard
HW upgrade for support of BiSS, SSI and Technology Guard for 8EI8X8MWT10.0100-1 within Automation Studio.
ACP10 minimumversion V3.12.0
Channel description changed: no
Configuration description changed: no
Firmware changed: no

Version1.0.0.1:

ID: 461725
HW upgrade for 8EI8X8MWT10.0100-1
HW upgradefor Support of 8EI8X8MWT10.0100-1 within Automation Studio.
ACP10 minimumversion V3.10.0
Channel description changed: no
Configuration descriptionchanged: no
Firmware changed: no

Version 1.0.0.0:

ID: 457645
HW upgrade for 8EI8X8MWT10.0100-1
HW upgrade for Support of 8EI8X8MWT10.0100-1 within Automation Studio.
ACP10 minimumversion V3.10.0
Channel description changed: no
Configuration description changed: no
Firmware changed: no
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.3.2.0 * 20/07/2023 560 KB EXE AS4_HW_8EI8X8MWT10.0100-1.exe
Opis V4.0 HW Upgrade (8EI8X8MWT10.0100-1)

Revision information 8EI8X8MWT10.0100-1

Version 2.3.2.0:

ID: 728020 / Support ID: 400353504
Wrong description for encoder connector in module configuration
For some modules the description of the encoder connector was wrong.
The description of the encoder connector in the configuration in AS was not the same as on the housing of the module.

Added attribute "Label" for encoder connectors.

-Automation Studio version AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 768625
Support of new ACP P3 modules 8EI*-2
The following modules are now supported:
8EI2X2HCT10.XXXX-2
8EI2X2HWT10.XXXX-2
8EI2X2MCT10.XXXX-2
8EI2X2MWT10.XXXX-2
8EI4X5HCT10.XXXX-2
8EI4X5HWT10.XXXX-2
8EI4X5MCT10.XXXX-2
8EI4X5MWT10.XXXX-2
8EI8X8HCT10.XXXX-2
8EI8X8HWT10.XXXX-2
8EI8X8MCT10.XXXX-2
8EI8X8MWT10.XXXX-2


-Automation Studio version AS 4.0.11
-mapp Motion version 5.24
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.1.2:

ID: 728020 / Support ID: 400353504
Wrong description for encoder connector in module configuration
For some modules the description of the encoder connector was wrong.
The description of the encoder connector in the configuration in AS was not the same as on the housing of the module.

Added attribute "Label" for encoder connectors.

-Automation Studio version AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.1.1:

ID: 707900
Correct display of the DC-Bus Voltage in the speed torque chart.
The DC bus voltage from the configuration of the module is adopted in the Speed ​​Torque Chart.
This function is supported from AS 4.10.
The following upgrades don´t support the Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.3:

ID: 653390
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 683190
Added description "(PLK)" forattribute "Label" for Powerlink connectors
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.2:

ID: 622565
Parameter "SdcEnabled" initializedincorrectly
Data type of parameter was changed to STRING and inital value to "off".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.3.1.1 * 27/11/2020 240 KB EXE AS4_HW_8EI8X8MWT10.0100-1.exe
Opis V4.0 HW Upgrade (8EI8X8MWT10.0100-1)

Revision information 8EI013HCS10.xxxx-1

Version 2.3.1.1:

ID: 707900
Correct display of theDC-Bus Voltage in the speed torque chart.
The DC bus voltage from the configuration of the module is adopted in the Speed ​​Torque Chart.
This function is supported from AS 4.10.
The following upgrades don´t support the Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.1.0:

ID: 446210 / Support ID: 400193653, 400199515, 400216656, 400240315, 400244641, 400259325, 400259805,400264294, 400264504, 400267855, 400276023, 400282533, 400286540, 400293220, 400292633, 400307303, 400307335, 400318959, 400325019, 400330060
Support of Speed Torque Chart in Automation Studio for ACOPOS P3
Extension of thehardware upgrades to support the Speed Torque Chart for ACOPOS P3.
This function is supported from AS 4.10.
The following upgrades don´t support the Speed Torque Chart
8EIxxxHxD1x.xxxx-1
8EIxxxHxS1x.xxxx-1
8EIxxxHxT1x.xxxx-1
8EIxxxMxD1x.xxxx-1
8EIxxxMxS1x.xxxx-1
8EIxxxMxT1x.xxxx-1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.3:

ID: 653390
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: No
Configuration description changed:Yes
Firmware changed: No

ID: 683190
Added description "(PLK)" for attribute "Label" for Powerlink connectors
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.3.0.2:

ID: 622565
Parameter "SdcEnabled" initialized incorrectly
Data type of parameter was changed to STRING and inital value to "off".
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.3.0.3 * 09/09/2020 239 KB EXE AS4_HW_8EI8X8MWT10.0100-1.exe
Opis V4.0 HW Upgrade (8EI8X8MWT10.0100-1)

Revision information 8EI8X8MWT10.0100-1

Version 2.3.0.3:

ID: 699970
Added description "(PLK)" for attribute "Label" for Powerlink connectors
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 699975
Misconfiguration of mapp Motion axis assignment not detected in Automation Studio
mapp Motion axes can be assigned to a drive multiple times. This error is not recognized until runtime.
Corrected in combination with:
- mapp Motion V5.4.0
- Automation Studio V4.4.4
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 699980
Parameter "SdcEnabled" initialized incorrectly
Data type of parameter was changed to STRING and inital value to "off".
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 699985
Support of T-Format (Tamagawa) and HIPERFACE DSL encoder added
-ACP10 version 5.08.0
-mapp Motion version 5.8.0
-Automation Studio version
AS 4.0.11
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.2.0.0:

ID: 549300
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.0.0.5:

ID: 523745
Encodertype added
Hiperface DSL is now selectablein the encoderconfiguration of ACOPOS P3.
ACP10 Minimumversion 3.16.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.0.0.4:

ID: 515600
Wrongdisplay of ACOPOS P3 modules in SDM.
Informations of ACOPOS P3 plug-in module and ACOPOS P3 motors weren't shown.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.0.0.3:

ID: 476920
ACOPOS P3 with encoder setting BISS or SSI
With setting BISS or SSI an error in the ARCONFIG occured and errornumber 32225: "This ACOPOS POWERLINK node does not exist in the AR Configuration" wasdisplayed.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 1.0.0.2:

ID: 462370
HW upgrade for support of BiSS, SSI and Technology Guard
HW upgrade for support of BiSS, SSI and Technology Guard for 8EI8X8MWT10.0100-1 within Automation Studio.
ACP10 minimumversion V3.12.0
Channel description changed: No
Configuration description changed: No
Firmwarechanged: No

Version 1.0.0.1:

ID: 461725
HW upgrade for 8EI8X8MWT10.0100-1
HW upgrade for Support of 8EI8X8MWT10.0100-1 within Automation Studio.
ACP10 minimumversion V3.10.0
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Wersja Język
System operacyjny
Data
Rozmiar
Typ Pobierz
2.2.0.0 * 01/09/2017 184 KB EXE AS4_HW_8EI8X8MWT10.0100-1.exe
Opis V4.0 HW Upgrade (8EI8X8MWT10.0100-1)

Revision information 8EI017HWS10.xxxx-1

Version 2.2.0.0:

ID: 549300
Support of motion system mapp Motion
HWX file extended for usage with motion system mapp Motion.
Channel description changed: No
Configuration description changed:No
Firmware changed: No

Version 1.0.0.0:

ID: 520095
HW upgrade for 8EI017HWS10.xxxx-1
HW upgrade for Support of 8EI017HWS10.xxxx-1 within Automation Studio.
Channel description changed: No
Configuration description changed: No
Firmware changed: No