DWL@DWL10000845240

Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
1.2.1.0 * 08-05-2026 2 MB EXE AS6_HW_X20SBD4M1.exe
Omschrijving V6.0 HW Upgrade (X20SBD4M1)

Revision information X20SBD4M1

Version 1.2.1.0:

ID: TDYD-11373
Documentation updated to v1.06
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: TDYD-11173
BISS and SSI: Improved error handling and revised error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\13213_2.fw(111)

Version 1.2.0.0:

ID: TDYD-11173
BISS and SSI: Improved error handling and revised error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\13213_2.fw(111)

Version 1.1.0.0:

ID: TDYD-10597
STO activation at high speeds can induce overvoltage
During the operation of stepper motors at high speeds,deactivation the PWM-Output stage (e.g. trigger of STO input) can induce unacceptably high voltages. To protect the device, a speed limit has been implemented based on the voltage constant.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\13213_2.fw(101)

Version 1.0.0.0:

ID: TDYD-10100
Support for the X20SBD4M1 module
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\13213_2.fw(100)
Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
1.2.0.0 * 29-04-2026 2 MB EXE AS6_HW_X20SBD4M1.exe
Omschrijving V6.0 HW Upgrade (X20SBD4M1)

Revision information X20SBD4M1

Version 1.2.0.0:

ID: TDYD-11173
BISS and SSI: Improved error handling and revised error messages.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\13213_2.fw(111)

Version 1.1.0.0:

ID: TDYD-10597
STO activation at high speeds can induce overvoltage
During the operation of steppermotors at high speeds,deactivation the PWM-Output stage (e.g. trigger of STO input) can induce unacceptably high voltages.To protect the device, a speed limit has been implemented based on the voltage constant.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\13213_2.fw(101)

Version 1.0.0.0:

ID: TDYD-10100
Support for the X20SBD4M1 module
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\13213_2.fw(100)
Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
1.1.0.0 * 05-03-2026 2 MB EXE AS6_HW_X20SBD4M1.exe
Omschrijving V6.0 HW Upgrade (X20SBD4M1)

Revision information X20SBD4M1

Version 1.1.0.0:

ID: TDYD-10597
STO activation at high speeds can induce overvoltage
During the operation of stepper motors at high speeds,deactivation the PWM-Output stage (e.g. trigger of STO input) can induce unacceptably high voltages. To protect the device, a speed limit has been implementedbased on the voltage constant.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\13213_2.fw(101)

Version 1.0.0.0:

ID: TDYD-10100
Support for the X20SBD4M1 module
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\13213_2.fw(100)
Versie Taal
Besturingssysteem
Datum
Grootte
Type Download
1.0.0.0 * 29-01-2026 2 MB EXE AS6_HW_X20SBD4M1.exe
Omschrijving V6.0 HW Upgrade (X20SBD4M1)

Revision information X20SBD4M1

Version 1.0.0.0:

ID: TDYD-10100
Support for the X20SBD4M1 module
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\13213_2.fw(100)
Loading
Terug naar overzicht

Graag land en taal kiezen

B&R Logo