DWL@DWL10000879073
| Versie | Taal | Besturingssysteem | Datum | Grootte | Type | Download |
|---|---|---|---|---|---|---|
| 1.7.0.1 | * | 12-10-2026 | 1 MB | EXE | AS6_HW_80PS080X3.10-01.exe | |
| Omschrijving |
V6.0 HW Upgrade (80PS080X3.10-01) Revision information 80PS080X3.10-01 Version 1.7.0.1: ID: Firmware signature enables automatic verification of the authenticity on the target system The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source. Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.7.0.0: ID: 778210 Configuration extension - additional module information Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\42921_3.fw(104), 1\42921_4.fw(104), 1\42921_5.fw(104), 1\42921_6.fw(104), 1\42921_7.fw(104) Version 1.6.0.0: ID: 752915 Steeper increase of output voltage can be activated via configuration A configuration was implemented specifically for compatibility with ACOPOSTrack segments, in which the output voltage of the power supply unit rises moresteeply Channel description changed: No Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42921_3.fw(104), 1\42921_4.fw(104), 1\42921_5.fw(104), 1\42921_6.fw(104), 1\42921_7.fw(104) Version 1.5.0.0: ID: 746015 Optimization of the control behavior with regenerative power supply in parallel operation Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42921_3.fw(103), 1\42921_4.fw(103), 1\42921_5.fw(103), 1\42921_6.fw(103), 1\42921_7.fw(103) Version 1.4.0.0: ID: 669195 Short circuit detection configurable Voltage threshold for undervoltage/short-circuit detection at power output Configurable Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 679200 Limitation of voltage at output X2 in case of HW defect Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42921_3.fw(102), 1\42921_4.fw(102), 1\42921_5.fw(102), 1\42921_6.fw(102), 1\42921_7.fw(102) Version 1.3.0.0: ID: 559755 Configured voltage is not output Wrongdoing: It occurs sporadically that the configured output voltage is not output afterstarting the device. The device must be restarted so that the correct voltage is output again. Troubleshooting: Error correction by new firmware. Workaround: Workaround is not possible. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42921_1.fw(6), 1\42921_2.fw(7), 1\42921_3.fw(101), 1\42921_4.fw(101), 1\42921_5.fw(101), 1\42921_6.fw(101) Version 1.2.4.0: ID: 421985 Optimization of current controller on Output OUT1 Minimization of ripple currents and voltage ripple for highest load range (about 1000 W) when Uout = 80VDC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42921_1.fw(6), 1\42921_2.fw(7), 1\42921_3.fw(100), 1\42921_4.fw(100) Version 1.2.3.0: ID: 332635 Optimized control for load alternation and when operated in parallel-mode Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42921_1.fw(6), 1\42921_2.fw(7), 1\42921_3.fw(7) Version 1.2.1.1: ID: 312075 Support for the module 80PS080X3.10-01 HW-Variant 3 Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 312085 Module bootup timeout configured Channel description changed: No Configuration descriptionchanged: Yes Firmware changed: No Firmware: 1\42921_1.fw(6), 1\42921_2.fw(6), 1\42921_3.fw(6) Version 1.1.1.0: ID: 303185 Set overload limit to 120% of nominal power to be conform with data sheet (for HW-Variant 2) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42921_1.fw(4), 1\42921_2.fw(5) Version 1.1.0.0: ID: 280120 Support for the module 80PS080X3.10-01 HW-Variant 2 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 280125 LED blink code for error conditions of OUT1 and OUT2 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 280130 Errors in power calculation for Bleedertemperature model Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 280135 Function model "CANIOBusController" Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\42921_1.fw(3), 1\42921_2.fw(3) Version 1.0.1.0: ID: 250855 80PS080X3 - Additional 24 VDC output problems Output Voltage of 24 VDCnot constant. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\42921_1.fw(2) Version 1.0.0.0: ID: 235255 Support for the module 80PS080X3.10-01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\42921_1.fw(1) |
|||||