DWL@DWL10000303029
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
|---|---|---|---|---|---|---|
| 1.13.0.0 | * | 2024/12/11 | 3 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP3586 Version 1.13.0.0: ID: QCAS-1019 POWERLINK: Lockup of MN operating 3rd party CN devices Unsynchronized frame reception in the MN caused by 3rd party CN blocked thecommunication. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\1538_0.pci(19), 1\1538a0.epl(143) Version 1.2.0.0: ID:772265 Wrong power consumption data corrected: calculated values in AS did not match to correct documentation Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\1538_0.pci(17), 1\1538a0.epl(141) Version 1.1.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.0.0.0: ID: 691650 Support PLCCP3585 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\1538_0.pci(17), 1\1538a0.epl(141) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.11.0.0 | * | 2023/07/20 | 3 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP3586 Version 1.11.0.0: ID: 772685 / Support ID: 400400350, 400406359, 400407650 Wrong power consumption data corrected: calculated values in AS did not match to correct documentation Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(142) Version 1.10.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.9.0.1: ID: 709895 Test Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(142) Version 1.9.0.0: ID: 691740 / Support ID: 400325418 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(142) Version 1.8.1.0: ID: 664845 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694590 Support for automatic DNA configuration fromAS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(141) Version 1.8.0.0: ID: 652280 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652445 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(141) Version 1.6.0.0: ID: 635430 Module documentation revised Data sheet V1.52 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 635555 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chainedstation" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(138) Version 1.5.0.0: ID: 542445 Changing the position of "Temperature data type configuration" in the CPU configuration Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 590110 X20CPx58x: I/O Datapoints "SupplyVoltage" and "SupplyCurrent" for onboard PS module Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 590125 Module documentation revised Data sheet V1.39 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 603380 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(136) Version 1.4.2.0: ID: 539065 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature displayrange Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.3.0.0: ID: 462635 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462670 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No ID: 462740 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462830 / SupportID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.2.0.0: ID: 443670 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 445155 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(15), 1\57886a0.epl(128) Version 1.1.0.0: ID: 417210 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417285 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417350 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417475 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 423955 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter,the dropping out of an SoC sometimes caused a permanent freezing of the inputdata on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424055/ Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(15), 1\57886a0.epl(127) Version 1.0.1.1: ID: 391700 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(13), 1\57886a0.epl(123) Version 1.0.1.0: ID: 391235 / Support ID: 0 Sporadic error when starting the onboard POWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(13), 1\57886a0.epl(123) Version 1.0.0.1: ID: 341970 Support X20cCP3586 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(12), 1\57886a0.epl(123) Version 1.0.0.0: ID: 341970 Support X20cCP3586 Firstversion Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(11), 1\57886a0.epl(121) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.10.0.0 | * | 2021/07/23 | 2 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP3586 Version 1.10.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.9.0.1: ID: 709895 Test Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(142) Version 1.9.0.0: ID: 691740 / Support ID: 400325418 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operatedin operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(142) Version 1.8.1.0: ID: 664845 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694590 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(141) Version 1.8.0.0: ID: 652280 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652445 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(141) Version 1.6.0.0: ID: 635430 Module documentation revised Data sheet V1.52 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 635555 POWERLINK-Manager: With frequent failure of CN's, which are operatedwith the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(138) Version 1.5.0.0: ID:542445 Changing the position of "Temperature data type configuration" inthe CPU configuration Channel description changed: No Configurationdescription changed: Yes Firmware changed: No ID: 590110 X20CPx58x: I/O Datapoints "SupplyVoltage" and "SupplyCurrent" for onboard PS module Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 590125 Module documentation revised Data sheet V1.39 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 603380 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization:Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(136) Version 1.4.2.0: ID: 539065 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.3.0.0: ID: 462635 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462670 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No ID: 462740 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462830 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.2.0.0: ID: 443670 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 445155 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(15), 1\57886a0.epl(128) Version 1.1.0.0: ID: 417210 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417285 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417350 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417475 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 423955 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424055 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled nodesometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(15), 1\57886a0.epl(127) Version 1.0.1.1: ID: 391700 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(13), 1\57886a0.epl(123) Version 1.0.1.0: ID: 391235 / Support ID: 0 Sporadic error when starting the onboard POWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(13), 1\57886a0.epl(123) Version 1.0.0.1: ID: 341970 Support X20cCP3586 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(12), 1\57886a0.epl(123) Version 1.0.0.0: ID: 341970 Support X20cCP3586 First version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(11), 1\57886a0.epl(121) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.9.0.0 | * | 2020/11/04 | 2 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP1584 Version 1.9.0.0: ID: 691740 / Support ID: 400325418 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operatingmode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17),1\57883a0.epl(142) Version 1.8.1.0: ID: 664845 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694590 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(141) Version 1.8.0.0: ID: 652280 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652445 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(141) Version 1.6.0.0: ID: 635430 Module documentation revised Data sheet V1.52 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 635555 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(138) Version 1.5.0.0: ID: 542445 Changing the position of "Temperature data type configuration" in the CPU configuration Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 590110 X20CPx58x: I/ODatapoints "SupplyVoltage" and "SupplyCurrent" for onboard PSmodule Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 590125 Module documentation revised Data sheet V1.39 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 603380 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically presentin the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(136) Version 1.4.2.0: ID: 537770 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.0.0: ID: 462620 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462640 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No ID: 462725 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462805 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.2.0.0: ID: 443655 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 445140 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(15), 1\57883a0.epl(128) Version 1.1.0.0: ID: 417225 Enhancement ECAD data Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 417310 Support Bonding feature Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 417365 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417495 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 423920 / SupportID: 400138730 POWERLINK V2: "Controlled node" mode In networks withheavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424035 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(15), 1\57883a0.epl(127) Version 1.0.1.1: ID: 391690 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.1.0: ID: 388285 / Support ID: 0 Sporadic error when starting the onboard POWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.0.1: ID: 311570 Support X20cCP1584 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(12), 1\57883a0.epl(123) Version 1.0.0.0: ID: 311570 Support X20cCP1584 First version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(11), 1\57883a0.epl(121) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.8.1.0 | * | 2020/08/20 | 2 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP1584 Version 1.8.1.0: ID: 664845 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 694590 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(141) Version 1.8.0.0: ID: 652280 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652445 Error correction: DNA tree topologies not always started up correctly Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(141) Version 1.6.0.0: ID: 635430 Module documentation revised Data sheet V1.52 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 635555 POWERLINK-Manager: With frequentfailure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(138) Version 1.5.0.0: ID: 542445 Changing the position of "Temperature data type configuration" in the CPU configuration Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 590110 X20CPx58x: I/O Datapoints "SupplyVoltage" and "SupplyCurrent" for onboard PS module Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 590125 Module documentation revised Data sheet V1.39 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 603380 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(136) Version 1.4.2.0: ID: 537770 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.0.0: ID: 462620 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462640 Update online help Channel description changed:No Configuration description changed: No Firmware changed: No ID: 462725 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462805 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.2.0.0: ID: 443655 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 445140 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(15), 1\57883a0.epl(128) Version 1.1.0.0: ID: 417225 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID:417310 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:417365 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417495 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 423920 / Support ID: 400138730 POWERLINKV2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424035 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINKmanager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(15), 1\57883a0.epl(127) Version 1.0.1.1: ID: 391690 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.1.0: ID: 388285 / Support ID: 0 Sporadic error when starting the onboard POWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.0.1: ID: 311570 Support X20cCP1584 Enhancement online-help Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\57883_0.pci(12), 1\57883a0.epl(123) Version 1.0.0.0: ID: 311570 Support X20cCP1584 First version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(11), 1\57883a0.epl(121) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.8.0.0 | * | 2019/12/12 | 2 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP1584 Version 1.8.0.0: ID: 652280 POWERLINK: Possible failure of alreadyconfigured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652445 Error correction: DNA tree topologiesnot always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(141) Version 1.6.0.0: ID: 635430 Module documentation revised Data sheet V1.52 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 635555 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(138) Version 1.5.0.0: ID: 542445 Changing the position of "Temperature data type configuration" in the CPU configuration Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 590110 X20CPx58x: I/O Datapoints "SupplyVoltage" and "SupplyCurrent" for onboard PS module Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 590125 Module documentation revised Data sheet V1.39 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 603380 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(136) Version 1.4.2.0: ID: 537770 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed:No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.0.0: ID: 462620 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462640 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No ID: 462725 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462805 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.2.0.0: ID: 443655 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 445140 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(15), 1\57883a0.epl(128) Version 1.1.0.0: ID: 417225 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417310 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417365 Documentation: enhancements and corrections Channel description changed:No Configuration description changed: No Firmware changed: No ID: 417495 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 423920 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of anSoC sometimes caused a permanent freezing of the input data on the controllednode. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424035 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(15), 1\57883a0.epl(127) Version 1.0.1.1: ID: 391690 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.1.0: ID: 388285 / Support ID: 0 Sporadic error when starting the onboard POWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.0.1: ID: 311570 Support X20cCP1584 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(12), 1\57883a0.epl(123) Version 1.0.0.0: ID: 311570 Support X20cCP1584 First version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(11), 1\57883a0.epl(121) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.6.0.0 | * | 2019/04/16 | 2 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP1584 Version 1.6.0.0: ID: 635430 Module documentation revised Datasheet V1.52 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 635555 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization"Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17),1\57883a0.epl(138) Version 1.5.0.0: ID: 542445 Changing the position of "Temperature data type configuration" in the CPU configuration Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 590110 X20CPx58x: I/O Datapoints "SupplyVoltage" and "SupplyCurrent" for onboard PS module Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 590125 Module documentation revised Data sheet V1.39 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 603380 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(136) Version 1.4.2.0: ID: 537770 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed:No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.0.0: ID: 462620 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462640 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No ID: 462725 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462805 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.2.0.0: ID: 443655 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 445140 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(15), 1\57883a0.epl(128) Version1.1.0.0: ID: 417225 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417310 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417365 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417495 Optimized EMC characteristics for GL Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 423920 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424035 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(15), 1\57883a0.epl(127) Version 1.0.1.1: ID: 391690 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.1.0: ID: 388285 / Support ID: 0 Sporadic error when starting the onboard POWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version1.0.0.1: ID: 311570 Support X20cCP1584 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(12), 1\57883a0.epl(123) Version 1.0.0.0: ID: 311570 Support X20cCP1584 First version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(11), 1\57883a0.epl(121) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.5.0.0 | * | 2018/09/07 | 2 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP1584 Version 1.5.0.0: ID: 542445 Changing the position of "Temperature data type configuration" in the CPU configuration Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 590110 X20CPx58x: I/O Datapoints "SupplyVoltage" and "SupplyCurrent" for onboard PS module Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 590125 Module documentation revised Data sheet V1.39 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 603380 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(136) Version 1.4.2.0: ID: 537770 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(17), 1\57883a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration descriptionchanged: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.3.0.0: ID: 462620 IP packets withmulticast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462640 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No ID: 462725 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462805 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(17), 1\57883a0.epl(129) Version 1.2.0.0: ID: 443655 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 445140 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(15), 1\57883a0.epl(128) Version 1.1.0.0: ID: 417225 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417310 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417365 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417495 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 423920 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out ofan SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424035 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(15), 1\57883a0.epl(127) Version 1.0.1.1: ID: 391690 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.1.0: ID: 388285 / Support ID: 0 Sporadic error when starting the onboardPOWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57883_0.pci(13), 1\57883a0.epl(123) Version 1.0.0.1: ID: 311570 Support X20cCP1584 Enhancement online-help Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\57883_0.pci(12), 1\57883a0.epl(123) Version 1.0.0.0: ID: 311570 Support X20cCP1584 First version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57883_0.pci(11), 1\57883a0.epl(121) |
|||||
| 仕様版 | 言語 | オペレーティングシステム | 日付 | サイズ | タイプ | ダウンロード |
| 1.4.2.0 | * | 2017/06/09 | 2 MB | EXE | AS4_HW_X20cCP3586.exe | |
| 説明 |
V4.0 HW Upgrade (X20cCP3586) Revision information X20cCP3586 Version 1.4.2.0: ID: 539065 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timingproblem in the firmware it could happen that no asynchronous frames were sentin the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(17), 1\57886a0.epl(131) Version 1.4.0.0: ID: 497865 Configurable negative temperature display range Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: No ID: 520790 Module documentation revised Data sheet V 1.37 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 521655 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.3.2.0: ID: 490210 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.3.0.0: ID: 462635 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462670 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No ID: 462740 / Support ID: 400134699 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462830 / Support ID: 400164226 Corrected DRAM sizes in documentation Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(17), 1\57886a0.epl(129) Version 1.2.0.0: ID: 443670 / Support ID: 400154848 IP packets with multicast addresses not received by the POWERLINK interface Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 445155 Documentation changed Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(15), 1\57886a0.epl(128) Version 1.1.0.0: ID: 417210 Enhancement ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 417285 SupportBonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 417350 Documentation: enhancements and corrections Channel description changed: No Configuration description changed: No Firmware changed: No ID: 417475 Optimized EMC characteristics for GL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 423955 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 424055 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, thecontrolled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(15), 1\57886a0.epl(127) Version 1.0.1.1: ID: 391700 / Support ID: 400137793 Correction terminal mode Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\57886_0.pci(13), 1\57886a0.epl(123) Version 1.0.1.0: ID: 391235 / Support ID: 0 Sporadic error when starting the onboard POWERLINK interface corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(13), 1\57886a0.epl(123) Version 1.0.0.1: ID: 341970 Support X20cCP3586 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\57886_0.pci(12), 1\57886a0.epl(123) Version 1.0.0.0: ID: 341970 Support X20cCP3586 First version Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\57886_0.pci(11), 1\57886a0.epl(121) |
|||||