DWL@DWL10000286135

仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
1.9.0.0 * 2023/09/22 1 MB EXE AS4_HW_5ACPCI.XPNS-00.exe
説明 V4.0 HW Upgrade (5ACPCI.XPNS-00)

Revision information 5ACPCI.XPNS-00

Version 1.9.0.0:

ID: 775400
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 775410
Upgraded field bus FWversions
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(103)

Version 1.8.0.0:

ID: 730345
Denial of Service vulnerability in PROFINET IO Device solved.
Denial of Service vulnerability in PROFINET IODevice solved.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(102)

Version 1.5.1.0:

ID: 628735
Exchange in Automation Studiooptimized
The replacement of the module works now correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 634590 / Support ID: 400280705
Dynamic configuration
The name of the generated netX module can be freely assigned inorder to enable a dynamic configuration of netX modules in AR.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45520a1.fw(101)

Version 1.5.0.0:

ID: 515705
DMA is activated again
Attention: In rare cases it waspossible, that an inconsistency in data transmission arised in combination with third party devices.
This problem is fixed with the hardware revision E0of the 5ACPCI.XPNS-00.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(101)

Version 1.3.0.0:

ID: 420055 / Support ID: 400143066, 400183504
Profinet communication stuck
Included new firmware version 3.5.52.1 and deactivated DMA
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(100)

Version 1.2.0.2:

ID: 377895
Added additionaldatapoints in the I/O Mapping
New datapoints: ModuleOK, SerialNumber, ModuleID, HardwareVariant, FimrwareVersion
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.2.0.1:

ID: 369965
Parameter added
Parameter "Manual start of bus communication" has been added in the I/O configuration.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.0.1.2:

ID: 240485
Configuration of netXcycle time
The cycle time for data exchange between CPU and netX can be configured now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45520a1.fw(3), 1\45520_1.fw(1)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
1.8.0.0 * 2021/06/25 754 KB EXE AS4_HW_5ACPCI.XPNS-00.exe
説明 V4.0 HW Upgrade (5ACPCI.XPNS-00)

Revision information 5ACPCI.XPNS-00.XPNS-00

Version 1.8.0.0:

ID: 730345
Denial of Service vulnerability in PROFINET IO Device solved.
Denial of Service vulnerability in PROFINET IO Device solved.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(102)

Version 1.5.1.0:

ID: 628735
Exchange in Automation Studio optimized
The replacement of the module works now correctly.
Channel description changed: No
Configuration description changed:No
Firmware changed: No

ID: 634590 / Support ID: 400280705
Dynamic configuration
The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45520a1.fw(101)

Version 1.5.0.0:

ID: 515705
DMA is activated again
Attention: In rarecases it was possible, that an inconsistency in data transmission arised in combination with third party devices.
This problem is fixed with the hardware revision E0 of the 5ACPCI.XPNS-00.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(101)

Version 1.3.0.0:

ID: 420055 / Support ID:400143066, 400183504
Profinet communication stuck
Included new firmware version 3.5.52.1 and deactivated DMA
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(100)

Version 1.2.0.2:

ID: 377895
Added additional datapoints in the I/O Mapping
New datapoints: ModuleOK, SerialNumber, ModuleID, HardwareVariant, FimrwareVersion
Channel descriptionchanged: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.2.0.1:

ID: 369965
Parameter added
Parameter "Manual start of bus communication" hasbeen added in the I/O configuration.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.0.1.2:

ID: 240485
Configuration of netX cycle time
The cycle time for data exchange between CPU andnetX can be configured now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45520a1.fw(3), 1\45520_1.fw(1)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
1.5.1.0 * 2019/03/06 734 KB EXE AS4_HW_5ACPCI.XPNS-00.exe
説明 V4.0 HW Upgrade (5ACPCI.XPNS-00)

Revision information 5ACPCI.XPNS-00

Version 1.5.1.0:

ID: 628735
Exchange in Automation Studio optimized
The replacement of the module works now correctly.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No

ID: 634590 / Support ID: 400280705
Dynamic configuration
The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45520a1.fw(101)

Version 1.5.0.0:

ID: 515705
DMA is activated again
Attention: In rare cases it was possible, that an inconsistency in data transmission arised in combination with third party devices.
This problem is fixed with the hardware revision E0 of the 5ACPCI.XPNS-00.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(101)

Version 1.3.0.0:

ID: 420055 / Support ID: 400143066, 400183504
Profinet communication stuck
Included new firmware version 3.5.52.1 and deactivated DMA
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(100)

Version 1.2.0.2:

ID: 377895
Added additional datapoints in the I/O Mapping
New datapoints: ModuleOK, SerialNumber, ModuleID, HardwareVariant, FimrwareVersion
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.2.0.1:

ID: 369965
Parameter added
Parameter "Manual start of bus communication" has been added inthe I/O configuration.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.0.1.2:

ID: 240485
Configuration of netX cycle time
The cycle time for data exchange between CPU and netX can be configured now.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45520a1.fw(3), 1\45520_1.fw(1)
仕様版 言語
オペレーティングシステム
日付
サイズ
タイプ ダウンロード
1.5.0.0 * 2017/03/03 801 KB EXE AS4_HW_5ACPCI.XPNS-00.exe
説明 V4.0 HW Upgrade (5ACPCI.XPNS-00)

Revision information 5ACPCI.XPNS-00

Version 1.5.0.0:

ID: 515705
DMA is activated again
Attention: In rare cases it was possible, that an inconsistency in data transmission arised in combination with third party devices.
This problem is fixed with the hardware revision E0 of the 5ACPCI.XPNS-00.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(101)

Version 1.3.0.0:

ID: 420055 / Support ID: 400143066, 400183504
Profinet communication stuck
Included new firmware version 3.5.52.1 and deactivated DMA
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\45520a1.fw(100)

Version 1.2.0.2:

ID:377895
Added additional datapoints in the I/O Mapping
New datapoints: ModuleOK, SerialNumber, ModuleID, HardwareVariant, FimrwareVersion
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.2.0.1:

ID: 369965
Parameter added
Parameter "Manual start of bus communication" has been added in the I/O configuration.
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\45520a1.fw(04)

Version 1.0.1.2:

ID: 240485
Configuration of netX cycle time
The cycle time for data exchangebetween CPU and netX can be configured now.
Channel description changed:No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\45520a1.fw(3), 1\45520_1.fw(1)