DWL@DWL10000861896
| Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
|---|---|---|---|---|---|---|
| 2.5.2.0 | * | 10/06/2026 | 21 Mo | EXE | AS6_HW_8I76xxxxxxx.0P-xxx.exe | |
| Description |
V6.0 HW Upgrade (8I76xxxxxxx.0P-xxx) Revision information 8I76xxxxxxx.0P-xxx Version 2.6.0.0: ID: 754470 Interaction between communication card and drive revised Up to now, the internal communication between communication card and drive was kept on Schneider's default setting. Now, operation mode was adapted to the circumstances of a POWERLINK network. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\62042_1.fw(201), 1\62042_2.fw(201), 1\62042_30.fw(201) Version 2.5.1.1: ID: AHBM-523 Compatibility version of interfacefirmware V180 with new hardware variant 3 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\62042_1.fw(180), 1\62042_2.fw(180), 1\62042_3.fw(181) Version 2.5.1.0: ID: 742210 mappMotion inplementation restored Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 742805 Harmonization of module configuration (Group: Axis management) The user surfaces for the product group ACOPOSinverter was designed specially. One demands is to provide a homogeneous structure for all devices of the product generation. This harmonization of several device from different vendorsresults in a similar commissioning process and simplisfies a product change within the productgroup. The extension of the product group by the ACPi P96 forced adaptions ofthe general structure. These changes are rolled out to the products that havealready been published. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\62042_1.fw(180), 1\62042_2.fw(180) Version 2.5.0.0: ID: 738360 Continuous product improvement Optimization of initial commissioning. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\62042_1.fw(180), 1\62042_2.fw(180) Version 2.4.0.0: ID: 727200 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727210 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IPstack was affected by a security vulnerability impacting the checksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727275 Boot routine of PLK communication card revised The state of the reset-line of the inverter is now taken into account during re/booting Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 727290 DS402-PLK-objects revised Revision and correction of PLK object 0x6060 and 0x6061 DS402 operation mode) Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 727295 Parameter FLR revised The parameter FLR is added to the module configuration in Automation Studio. It turn on the function "Catch on the fly", that permitts the restart of a coasting motor (motor in freewheel stop). Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 730190 Automation Runtime versions greater D3.10 supported Support of Automation Runtime versions greater D3.10 (up to now minimum version required was D4.10) Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\62042_1.fw(170), 1\62042_2.fw(170) Version 2.3.3.0: ID: 714060 Configuration parameters for current and torque limitation revised Structural bugin hardware upgrade version 2.3.2.0 eliminated. The configuration parameters for current and torque limitation were not shown if function model "Motion Control" was chosen. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 714070 Singlebits initialisation (parameter BRH) revised The configuration bits of parameter BRH can be downloaded as shown in the configuration view. Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\62042_1.fw(160), 1\62042_2.fw(160) Version 2.3.2.0: ID: 667480 Filter conditions for hardware catalog revised The ACOPOSinverter is still shown, if module selection is resticted to "single axis" modules. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 694755 External error detection revised The error message EPF1 does not haveto be acknowledged after a restart - even not if the external error detectionis used in low active mode. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 695295 Configuration parameter SFR revised If the operating mode for long motor cable is selected (Parameter SVL = YES), the value range for the stator frequency is restricted; the valid maximum is reduced to 4 kHz (Instead of this,the minimum value was raised to 4 kHz in previous versions). Channel description changed: No Configuration description changed: Yes Firmwarechanged: No ID: 701980 Correction of configuration surface The "axis behavior in case of error" can be defined by the user (see Moduleconfiguration: Function model > ACOPOSinverter parameters >General hardware setup > Drive > Axis management >Reference model > Stop commands > DS 402 state machine). The adaption eliminates a structural fault in the confguration surface that can cause a reset of this userdefined configuration in case of changing the thegeneral hardware setup. CAUTION: After changing to this version, the setting for the "axis behavior in case of error"must be verified. This is ecessary especilyy if the general hardware setup for synchronous motors or asynchronous motors with holding brake is used. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 702900 Module configuration correted The module configuration of function model "motion configuration" seemed tobe able to switch between rpm and Hz as setpoint unit. However, the switch works only if function model "direct control" was selected before. The ineffective swtich was eliminated from the configuration surface. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 704745 Restrictions for se in AutomationStudio (Aprol-Edition) added Due to the faulty processing of the hardware description files in the Aproledition of AutomationStudio, the product release for Aprol projects must be restricted to APROL R 4.2-06 and higher. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\62042_1.fw(160), 1\62042_2.fw(160) Version 2.2.0.1: ID: 619895 Support for mappMotion Support for mappMotion (from version 5.8) The usage of the onboard POWERLINK interfaces on ARM CPUs (e.g. X20CP04xx) for mappMotion is restricted to the following minimun versions of AutomationRuntime; M4.34, F4.45, C4.53, C4.63, A4.72 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 657100 List of monitoring data points extended The list of optional monitoring data points was extended to enable access to unfiltered values (SRFR, SOTR, SLCR, SOPR, SULN) Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\62042_1.fw(110) Version 1.1.0.5: ID: 637255 POWERLINK communication revised Ongoing product improvements - Ring redundancy: Cannot address the CN that closes the ring - Optimization of hub behavior - Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors - DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 637535 Download ofParameter "OPL" revised The parameter "OPL" can be used to activate/deactivate the supervision "output phase loss". Channel description changed: No Configuration description changed: No Firmware changed: No ID: 638525 Configuration view extended and corrected Configuration view revised Access: Configuration parameter RSF added Intermediate circuit: Configuration parameter DCCM always visible Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 638655 List of monitoring data points extended The list of optional monitoring data points was extended by data point SMSS(status of safety function "Safe Maximum Speed") Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 638665 ERROR CORRECTION The following optional monitoring datapoints had to be renamed: 1. GDLS, 2.ETAD(unpacked). In consequence of double naming of the optional input data points, a malicious behavior of AutomationStudio can occur. After switching to the upgrade version, the links of the affected data points have to be checked and if necessary restored. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 638685 Download of motor data for synchronousmotors enabled Bug eliminated which avoided the download of motor data for synchronous motors. Channel description changed: No Configurationdescription changed: No Firmware changed: No ID: 639625 Behavior of 7 segment display adapted After downloading the parameter set of the ACOPOSinverter, the display switches to the actual state of the drive. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 642740 Download of the "I²t" motor temperature model revised The parameters of the "I²t" motor temperaturemodel (ITH, MTM, THT) can be downloaded as shown in the configuration view. Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 645290 Maximum speed definition revised The "TFR [Hz]" does not need to be configured anymore if the "rpm" reference model is used. The valid maximum speed of the axis is defined exclusively byparameter "SMA [rpm]". Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 649485 Module documentation revised User manual V 1.20 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\62042_1.fw(110) Version 1.0.2.0: ID: 631640 Support ACOPOSinverter P76-P Support for AutomationStudio Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 633575 General input template - BLC revised The sub function PES "external weight measurement" was unlock in the general input template "BLC function: Brake control (ASM)". It can be used for dynamic braking on vertical load movement scenarios. Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\62042_1.fw(101) |
|||||