DWL@DWL10000878148

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.4.2.1 * 06/10/2026 2 Mo EXE AS6_HW_X20CS1012.exe
Description V6.0 HW Upgrade (X20CS1012)

Revision information X20CS1012

Version 1.4.2.1:

ID:
Firmware signature enables automatic verification of the authenticity on the target system
The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source.
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.4.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID: 591180
New firmware for hardware variant 3
Due to a component discontinuation, the hardware had to be revised.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\51903_1.fw(212), 1\51903_2.fw(212), 1\51903_3.fw(212)

Version 1.1.1.1:

ID: 511960
Module documentation revised
Data sheet V1.16
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware:1\51903_1.fw(211), 1\51903_2.fw(211)

Version 1.1.1.0:

ID: 495100
Module documentation revised
Data sheet V1.15
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\51903_1.fw(211), 1\51903_2.fw(211)

Version 1.1.0.1:

ID: 470055
Module firmware has been adapted
The module is able to evaluate up to 48 parameters form a MBus slave. So the user candemand datenindices from 1 to 48 (previously 1-32).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\51903_1.fw(211), 1\51903_2.fw(211)

Version 1.0.5.0:

ID: 456890
Module documentation revised
Datasheet V1.13
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\51903_1.fw(210), 1\51903_2.fw(210)

Version 1.0.4.0:

ID: 433165
Ecad Section Correction
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 442250
Correction documentation
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\51903_1.fw(210), 1\51903_2.fw(210)

Version 1.0.3.1:

ID: 414965
FW modification
- FlatStream synchronisation modified
- error correction, if too many parameters are requested by FlatStream
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 425610
MBus Compatibility extended
DIF values with variable data length (0x0D) can be processed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\51903_1.fw(210), 1\51903_2.fw(210)

Version 1.0.2.1:

ID: 409030
Hardware file exdented
MBusComand byte can be used acyclically.
UART can be desabled when using flat steam interface only.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\51903_1.fw(208), 1\51903_2.fw(208)

Version 1.0.2.0:

ID: 400720
Firmware extened
The modules firmware was adapted for ensuring parameter request on more MBus slaves.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\51903_1.fw(208), 1\51903_2.fw(208)

Version 1.0.1.2:

ID: 387015
Signaltypes for APROL corrected
Channel descriptionchanged: Yes
Configuration description changed: No
Firmware changed: No
Firmware: 1\51903_1.fw(110), 1\51903_2.fw(110)

Version 1.0.1.1:

ID: 371750
Timing problem gelöst
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\51903_1.fw(110), 1\51903_2.fw(110)

Version 1.0.0.7:

ID: 330976
Module internal receive- and send buffers corrected
Ensuring the request of raw data on M-Bus slaves with variable data structure, the module internal communication buffers have been adapted to M-Bus specification.

Calculation of M-Bus data length in flatstream frame changed and adapted to infinite number of slaves in M-Bus network.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\51903_1.fw(107)

Version 1.0.0.6:

ID: 307035
Support X20CS1012
Support for AutomationStudio incl. documentation
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 322210
Allow Broadcast Adresse 254
If only one MBus Slave is connected to the X20CS1012, data canbe requested by using primary address 254.
(If supported by Mbus slave, this option can also be used, if primary addressof slave is set to 0.)
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes

ID: 322585
Timing problem emilinated
In case of bad configuratrion UART stoped, altough communication had been runed error-free for a random period of time before.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\51903_1.fw(106)

Version 1.0.0.2:

ID: 298515
Support X20CS1012
Support for AutomationStudio incl. documentation (german)
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\51903_1.fw(102)

Version 1.0.0.0:

ID: 293370
Support X20CS1012
Support for AutomationStudio
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\51903_1.fw(102)
Loading