DWL@DWL10000878428

Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.3.0.1 * 07.10.2026 3 MB EXE AS6_HW_X67DC1198.exe
Descripción V6.0 HW Upgrade (X67DC1198)

Revision information X67DC1198

Version 1.3.0.1:

ID:
Firmware signature enables automatic verification of the authenticity on the target system
The firmware package contains a digital signature that is automatically validated by Automation Runtime versions, which are supporting this feature. Thisensures that the installed firmware is unchanged and comes from a trusted source.
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.3.0.0:

ID: 770620
New function model "MotionConfiguration" for mappMotion
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_10.fw(115), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(11)

Version 1.2.0.0:

ID: 715515
Support new HW-variant 10
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_10.fw(1), 1\6352_2.fw(105), 1\6352_3.fw(105),1\6352_5.fw(11)

Version 1.1.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.0.6.0:

ID: 547605
Module documentation revised
Data sheet V3.02
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(11)

Version 1.0.5.0:

ID: 519555
Module documentation revised
Data sheet V3.00
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(11)

Version 1.0.4.0:

ID: 268675
Enhancement length check of I/O block size during Build
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(11)

Version 1.0.3.1:

ID: 237195
Customer-specific expansion of hardware description file
This upgrade has no impact on the Automation Studio and the standard version of the FieldbusDESIGNER
Channel description changed: No
Configurationdescription changed: Yes
Firmware changed: No
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(11)

Version 1.0.3.0:

ID: 197310
Comparator problem corrected. ATTENTION :: incompatibility at window margin
New FW V11 : comparator problem corrected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\6352_0.fw(105),1\6352_1.fw(105), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(11)

Version 1.0.2.0:

ID: 177490
Enhancement SSI encoder configuration and position latch, correction internal communication
Enhancement monoflop check SSI encoder configuration and position latch with pos./neg. edge, correction internal communication
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(10)

Version 1.0.1.0:

ID: 163715
New Firmware V9
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\6352_0.fw(105), 1\6352_1.fw(105), 1\6352_2.fw(105), 1\6352_3.fw(105), 1\6352_5.fw(10)
Loading
Volver al listado

Seleccione país e idioma

B&R Logo