DWL@DWL10000811542

Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.1.1.1 * 18.08.2026 3 MB EXE AS6_HW_X20DS838A.exe
Descripción V6.0 HW Upgrade (X20DS838A)

Revision information X20DS838A

Version 1.1.1.1:

ID: QCAS-3535
CVE-2025-43715: Installer is vulnerable to local privilege escalation
The installation system NSIS used by B&Rcan allow local attackers to escalate their privileges.
CVE-2025-43715, CVSS: 8.1 (High) CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.1.0:

ID: TDYD-9534
Support BOOL[8]Process Data and fix the issue in the parameter server
hwx-adaption:
In addition, the data type BOOL[8] is now also available for input and outputprocess data, in which the eight bits are stored as individual Boolean valuesin the I/O mapping.
The register addresses in the HWX file have been corrected for the ParameterCtrOut.
Versioning error in 1.1.0.0 has been fixed.

FW-adaption:
In the sequence for data storage (parameter server), additional commands wereincluded that, in combination with certain devices, caused problems. This issue has been resolved.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(103)

Version 1.1.0.0:

ID: TDYD-9534
Support BOOL[8] Process Data and fix the issue in the parameter server
hwx-adaption:
In addition, the data type BOOL[8] is now also available for input and outputprocess data, in which the eight bits are stored as individual Boolean valuesin the I/O mapping.
The register addresses in the HWX filehave been corrected for the ParameterCtrOut.


FW-adaption:
In the sequence for data storage (parameter server), additional commands wereincluded that, in combination with certain devices, caused problems. This issue hasbeen resolved.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(103)

Version 1.0.0.0:

ID: TDYD-6352
Support of X20DS838A
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(102)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.1.1.0 * 18.05.2026 3 MB EXE AS6_HW_X20DS838A.exe
Descripción V6.0 HW Upgrade (X20DS838A)

Revision information X20DS838A

Version 1.1.1.0:

ID: TDYD-9534
Support BOOL[8] Process Data and fix the issue in the parameter server
hwx-adaption:
In addition, the data type BOOL[8] is now also available for input and outputprocess data, in whichthe eight bits are stored as individual Boolean values in the I/O mapping.
The register addresses in the HWX file have been corrected for the ParameterCtrOut.
Versioning error in 1.1.0.0 has been fixed.

FW-adaption:
In the sequence for data storage (parameter server), additional commands wereincluded that, in combination with certain devices, caused problems. This issuehas been resolved.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(103)

Version 1.1.0.0:

ID: TDYD-9534
Support BOOL[8] Process Data and fix the issue in the parameter server
hwx-adaption:
In addition, the data type BOOL[8] is now also available for input and outputprocess data, in which the eight bits are stored as individual Boolean valuesin the I/O mapping.
The register addresses in the HWX file have been corrected for the ParameterCtrOut.


FW-adaption:
In the sequence for data storage (parameter server), additional commands wereincluded that, in combination with certain devices, caused problems. This issue has been resolved.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(103)

Version 1.0.0.0:

ID: TDYD-6352
Support of X20DS838A
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(102)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.1.0.0 * 27.04.2026 3 MB EXE AS6_HW_X20DS838A.exe
Descripción V6.0 HW Upgrade (X20DS838A)

Revision information X20DS838A

Version 1.1.0.0:

ID: TDYD-9534
Support BOOL[8] Process Data and fix the issue in the parameter server
hwx-adaption:
In addition, the data type BOOL[8] is now also available for input and outputprocess data, in whichthe eight bits are stored as individual Boolean values in the I/O mapping.
The register addresses in the HWX file have been corrected for the ParameterCtrOut.


FW-adaption:
In the sequence for data storage (parameter server), additional commands wereincluded that, in combination with certain devices, caused problems. This issue has been resolved.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(103)

Version 1.0.0.0:

ID: TDYD-6352
Support of X20DS838A
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(102)
Versión Idioma
Sistema operativo
Fecha
Tamaño
Tipo Descargar
1.0.0.0 * 20.02.2025 3 MB EXE AS6_HW_X20DS838A.exe
Descripción V6.0 HW Upgrade (X20DS838A)

Revision information X20DS838A

Version 1.0.0.0:

ID: TDYD-6352
Support of X20DS838A
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\12462_1.fw(102)
Loading
Volver al listado