V4.0 HW Upgrade (5PP552.0573-00)

DWL@DWL10000244587

Version Language
Operating System
Date
Size
Type Download
2.1.3.1 * 07/26/2021 287 KB EXE AS4_HW_5PP552.0573-00.exe
Description V4.0 HW Upgrade (5PP552.0573-00)

Revision information 5PP552.0573-00.0573-00

Version 2.1.3.1:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration descriptionchanged: yes
Firmware changed: no

Version 2.0.3.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.2.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.2:

ID: 344775
The RTOS driver for COM1 must not be installed in the Windows Device Manager
ARwin does not requires RTOS-Driver for COM1 with aktive INA Communication
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.1:

ID: 288000
ARwin: Support for second Ethernet-interface
For support of a second Ethernet interface itwas necassary to introduce a new parameter in hwd-section.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.1.0:

ID: 279545
Important information!
Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xx have a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPUboards), 5PP5IF* (interface boards), 5PP5IO* (I/O boards).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 285400
Preperation to support a second Ethernet interface
-
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.4:

ID: 266945
Support for USB keyboards
USB keyboards can be projected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.3:

ID: 262220
Problem with ARwin & embedded terminal client
The operation of an embedded terminal client on 5PP552.0573-00 with operating Automation Runtime Windows(ARwin) caused a black screen on the terminal device. This malfunction was corrected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.2:

ID: 261645
Correction of incorrect key assignment
The incorrect key assignment was corrected in the corresponding hardware description file.
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.1:

ID: 261240
Problems with terminal modes
Problems, that occured in connection with the terminal modes, were corrected with changes in the respective hardware description files.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 255945
Support for 5PP552.0573-00
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Version Language
Operating System
Date
Size
Type Download
2.0.3.0 * 07/18/2016 302 KB EXE AS4_HW_5PP552.0573-00.exe
Description V4.0 HW Upgrade (5PP552.0573-00)

Revision information 5PP520.0573-00

Version 2.0.3.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.2.0:

ID: 482810 / Support ID: 400188739
Support as Modbus TCP Slave in ARwin
The Modbus TCP Slave is supported with AS4.1.4.x and ARwin version G4.10 orwith AS4.2.4.x and ARwin version A4.24.
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.2:

ID: 344710
The RTOS driver for COM1 must not be installed in the Windows Device Manager
ARwin does not requires RTOS-Driver for COM1 with aktive INA Communication
Channel description changed: No
Configuration description changed: No
Firmware changed: No

Version 2.0.1.1:

ID: 287945
ARwin: Support for second Ethernet-interface
For support of a second Ethernet interface it was necassary to introduce a new parameter in hwd-section.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 2.0.1.0:

ID: 278345
Important information
Attention, important information: If this upgrade will be installed in conjunction with Automation Runtime >= A4.01,
it is absolutely necassery because of a conceptual change in the hardware representation,
that all of the components of used PP500/APC5xxhave a version >= V2.0.0.0,
otherwise it may be compatibility problems with the used Automation Runtime.
Affected are the following components: 5PP5##* (system units), 5PP5CP* (CPUboards), 5PP5IF* (interface boards), 5PP5IO* (I / O boards).
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 285250
Preperation to support a second Ethernet interface
-
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.5:

ID: 266825
Error in the addressing
Because of collision of USB and COM interface, the USB is postponed to IF2 und IF3.
Channel description changed: No
Configuration descriptionchanged: Yes
Firmware changed: No

Version 1.0.0.4:

ID: 266720
Support for USB keyboards
USB keyboards can be projected.
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.3:

ID: 259035
Problems with terminal modes
Problems, that have arisen in connection with the terminal modes, will be corrected with changes in the respective hardware description files.
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

Version 1.0.0.0:

ID: 255455
Support for 5PP520.0573-00
Channel description changed:Yes
Configuration description changed: Yes
Firmware changed: Yes