DWL@DWL10000342066
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
|---|---|---|---|---|---|---|
| 1.15.0.0 | * | 20/07/2023 | 5 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT Version 1.15.0.0: ID: 772660 / Support ID: 400400350, 400406359, 400407650 Wrong power consumption data corrected: calculated values in AS did not match to correct documentation Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(17), 1\58206a0.epl(142) Version 1.14.0.0: ID: 736765 Fixed boot and warm restart issue In rare cases the X20CP13xx does not boot correctly after a restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(17), 1\58206a0.epl(142) Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 704900 POWERLINK: Operating mode"Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(142) Version 1.11.1.0: ID: 664930 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channeldescription changed: Yes Configuration description changed: No Firmware changed: No ID: 695245 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.11.0.0: ID: 673085 Additional status bit for rtiABRPos reference impulse loss An additional statusbit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673135 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.10.0.0: ID: 652295 POWERLINK: Possible failure of already configured CNs if new "chained stations" addedduring operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652390 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669010 Module documentation revised Datasheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(13), 1\58206a0.epl(141) Version 1.8.0.0: ID: 635890 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 636545 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(13), 1\58206a0.epl(138) Version 1.7.0.0: ID: 610700 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be receivedfrom all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610710 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wrong length check of reACTION task Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 new FUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDiv Runtime-Correction in hwx Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 472835 Instable reACTION cycle time caused by rtiPWM andrtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Moduledocumentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479345 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgrade file corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK managerfailed, the controlled node sometimes registered with an incorrect NMT statusin the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 SupportX20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.6: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT FirstVersion Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.14.0.0 | * | 24/09/2021 | 5 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT-RT Version 1.14.0.0: ID: 736765 Fixed boot and warm restart issue In rare cases the X20CP13xx does not boot correctly after a restart Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(17), 1\58206a0.epl(142) Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 704900 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(142) Version 1.11.1.0: ID: 664930 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configurationdescription changed: No Firmware changed: No ID: 695245 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.11.0.0: ID: 673085 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673135 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.10.0.0: ID: 652295 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652390 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669010 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(13), 1\58206a0.epl(141) Version 1.8.0.0: ID: 635890 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 636545 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(13), 1\58206a0.epl(138) Version 1.7.0.0: ID: 610700 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency"and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610710 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing the CPU Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wrong length check of reACTION task Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 new FUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDiv Runtime-Correction in hwx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472835 Instable reACTION cycle time caused by rtiPWM and rtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Module documentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed:No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479345 Datatransfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgrade file corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 SupportBonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed:Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.6: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware:1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.13.0.0 | * | 23/07/2021 | 4 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT-RT Version 1.13.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.12.0.0: ID: 704900 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet" and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(142) Version 1.11.1.0: ID: 664930 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 695245 Supportfor automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.11.0.0: ID: 673085 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of thereference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673135 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.10.0.0: ID: 652295 POWERLINK: Possible failure of already configured CNs ifnew "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652390 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669010 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(13), 1\58206a0.epl(141) Version 1.8.0.0: ID: 635890 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 636545 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(13), 1\58206a0.epl(138) Version 1.7.0.0: ID: 610700 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can causeno input data to be received from all CNs with setting "Optimization: Minimallatency". Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 610710 Correction ofthe functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent inthe mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wrong length check of reACTION task Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 new FUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDiv Runtime-Correction inhwx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472835 Instable reACTION cycle time caused by rtiPWM and rtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Module documentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479345 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgrade file corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing ofthe input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registeredwith an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.6: ID:355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.12.0.0 | * | 08/04/2021 | 4 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT-RT Version 1.12.0.0: ID: 704900 POWERLINK: Operating mode "Ethernet" If a POWERLINK interface was operated in operating mode "Ethernet"and connected to a POWERLINK network in this mode, the interface could fail. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(142) Version 1.11.1.0: ID: 664930 Support data point StorageWear, wear level of storage medium starting fromAR A4.90 Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 695245 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.11.0.0: ID: 673085 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673135 The insufficient synchronization of the local inputs has been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.10.0.0: ID: 652295 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652390 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669010 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(13), 1\58206a0.epl(141) Version 1.8.0.0: ID: 635890 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 636545 POWERLINK-Manager: With frequent failure of CN's, which are operatedwith the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(13), 1\58206a0.epl(138) Version 1.7.0.0: ID:610700 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are notphysically present in the network can cause no input data to be received fromall CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610710 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wrong length check of reACTION task Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 new FUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDiv Runtime-Correction in hwx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472835 Instable reACTION cycle time caused by rtiPWM and rtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Module documentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479345 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgradefile corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.6: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.11.0.0 | * | 28/01/2020 | 4 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT Version 1.11.0.0: ID: 673085 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 673135 The insufficient synchronization of the local inputshas been corrected. The local inputs are now delayed by 40ns. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(14), 1\58206a0.epl(141) Version 1.10.0.0: ID: 652295 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652390 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:669010 Module documentation revised Data sheet V 1.23 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(13), 1\58206a0.epl(141) Version 1.8.0.0: ID: 635890 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 636545 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization"Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(13),1\58206a0.epl(138) Version 1.7.0.0: ID: 610700 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization:Minimal latency" and "Chained station: On" that are not physically present inthe network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610710 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing theCPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wronglength check of reACTION task Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 new FUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDivRuntime-Correction in hwx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472835 Instable reACTION cycle time caused by rtiPWM and rtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Module documentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:479345 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgrade file corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode Innetworks with heavy SoC jitter, the dropping out of an SoC sometimes caused apermanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version1.0.0.6: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.0.0 | * | 11/12/2019 | 4 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT Version 1.10.0.0: ID: 652295 POWERLINK: Possible failure of already configured CNs if new "chained stations" added during operation Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 652390 Error correction: DNA tree topologies not always started up correctly Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 669010 Module documentation revised Data sheet V 1.23 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(13), 1\58206a0.epl(141) Version 1.8.0.0: ID: 635890 Module documentation revised Datasheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 636545 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressedby the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(13), 1\58206a0.epl(138) Version 1.7.0.0: ID: 610700 / Support ID:400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting"Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610710 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature displayrange Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wrong length check of reACTION task Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 newFUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDiv Runtime-Correction in hwx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472835 Instable reACTION cycle time caused by rtiPWM and rtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Module documentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479345 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgrade file corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 Support X20CP1382-RT Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.6: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channel description changed:Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmwarechanged: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.8.0.0 | * | 21/05/2019 | 4 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT Version 1.8.0.0: ID: 635890 Module documentation revised Data sheet V 1.21 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 636545 POWERLINK-Manager: With frequent failure of CN's, which are operated with the optimization "Chained station" it can be happen that failed CN's were not longer adressed by the manager. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(13), 1\58206a0.epl(138) Version 1.7.0.0: ID: 610700 / SupportID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause no input data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610710 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wrong length check of reACTION task Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 new FUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDiv Runtime-Correction in hwx Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472835 Instable reACTION cycle time caused by rtiPWM and rtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Module documentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479345 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgrade file corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 Support Bonding feature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 SupportX20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.6: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmwarechanged: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed:Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.7.0.0 | * | 06/09/2018 | 4 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20CP1382-RT Version 1.7.0.0: ID: 610700 / Support ID: 400250890 POWERLINK CNs with configuration "Optimization: Minimal latency": No input data received POWERLINK CNs with configuration "Optimization: Minimal latency" and "Chained station: On" that are not physically present in the network can cause noinput data to be received from all CNs with setting "Optimization: Minimal latency". Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 610710 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(12), 1\58206a0.epl(136) Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.6.0.0: ID: 542545 Configurable negative temperature display range Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version1.5.0.0: ID: 529350 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 534325 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 536910 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(131) Version 1.4.0.0: ID: 500555 / Support ID: 400199021 Corrected FW concerning wrong length check of reACTIONtask Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(11), 1\58206a0.epl(129) Version 1.3.2.0: ID: 495810 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.1.0: ID: 490235 Additional info data points FirmwareVersion and HardwareVariant Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.3.0.0: ID: 464565 hwx description corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472235 SystemDesigner adjustment Channel description changed: No Configuration description changed: No Firmware changed: No ID: 472255 new FUB rtiRegister Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 472265 rtiDiv Runtime-Correction in hwx Channel description changed: No Configuration description changed:No Firmware changed: No ID: 472835 Instable reACTION cycletime caused by rtiPWM and rtiDiv corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 475530 Module documentation revised Data sheet V 1.05 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 476115 Reduced CAN susceptibility to disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 479345 Data transfer errors on POWERLINK-Interface Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(10), 1\58206a0.epl(129) Version 1.2.0.1: ID: 460560 Problems with HW-upgrade file corrected Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.2.0.0: ID: 455395 IP packets with multicast addresses not received by POWERLINK interface (problem only occurs with Automation Runtime versions <A4.23) Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455425 Reduced X2X susceptibilityto disturbances Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 455760 Update online help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(8), 1\58206a0.epl(129) Version 1.1.0.0: ID: 443600 Support Bondingfeature Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 443620 / Support ID: 400138730 POWERLINK V2: "Controlled node" mode In networks with heavy SoC jitter, the dropping out of an SoC sometimes caused a permanent freezing of the input data on the controlled node. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:443640 / Support ID: 400150240 POWERLINK V2: "Controlled node" mode After a POWERLINK manager failed, the controlled node sometimes registered with an incorrect NMT status in the ident response. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(128) Version 1.0.3.0: ID: 434335 / Support ID: 400152273 hwx file correction Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.2.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(7), 1\58206a0.epl(123) Version 1.0.1.0: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.15: ID: 355325 Support X20CP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58206_0.pci(6), 1\58206a0.epl(123) Version 1.0.0.14: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(5), 1\58206a0.epl(123) Version 1.0.0.11: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.10: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.9: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.8: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.7: ID:355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(4), 1\58206a0.epl(123) Version 1.0.0.6: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.5: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.4: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.3: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: Yes Firmware: 1\58206_0.pci(3), 1\58206a0.epl(123) Version 1.0.0.2: ID: 355325 Support X20CP1382-RT Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\58206a0.epl(123), 1\58206_0.pci(3) Version 1.0.0.1: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Version 1.0.0.0: ID: 355325 Support X20CP1382-RT First Version Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.6.2.0 | * | 21/12/2017 | 4 MB | EXE | AS4_HW_X20CP1382-RT.exe | |
| Beskrivelse |
V4.1 HW Upgrade (X20CP1382-RT) Revision information X20cCP1382-RT Version 1.6.2.0: ID: 569150 hwx modifications Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.5.0.0: ID: 543215 X20(c)CP138x-RT module documentation revised Data sheet V 1.16 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 543220 Correct setting of ETH-parameters when replacing the CPU Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 543225 / Support ID: 400204420 POWERLINK V2: no asynchronous frames in mode NMT PRE_OPERATIONAL_1 Because of a timing problem in the firmware it could happen that no asynchronous frames were sent in the mode PRE_OPERATIONAL_1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\59143_0.pci(11), 1\59143a0.epl(131) Version 1.4.0.0: ID: 490205 Support X20cCP1382-RT Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\59143_0.pci(11), 1\59143a0.epl(129) |
|||||