| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
|---|---|---|---|---|---|---|
| 1.10.12.0 | * | 16/04/2021 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.12.0: ID: 710650 Timing of module internal communication updated The timing of the module internal communication was updated. Sporadic errors 98818, 119317, 99348, 102914, 99350 no longer occur. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 710815 Limit values for the module cycle time adjusted The limit values for the calculation and monitoring of module cycle time and slot time adjusted. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\53765_1.fw(333) Version 1.10.11.0: ID: 692705 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692605 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\53765_1.fw(332) Version 1.10.10.2: ID: 669910 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.10.1: ID: 643460 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.10.0: ID: 614390 / Support ID: 400257973 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.9.0: ID: 618255 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(330) Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.11.0 | * | 17/09/2020 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.11.0: ID: 692705 Improvement of the internal voltage monitoring. Improvement of the internal voltage monitoring. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 692605 / Support ID: 400299371 Loss of safety connection Loss of safety connection, even though the parametrized "safe data duration" is longer than the network failure Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 7\53765_1.fw(332) Version 1.10.10.2: ID: 669910 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.10.1: ID: 643460 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.10.0: ID: 614390 / Support ID: 400257973 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.9.0: ID: 618255 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(330) Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.10.2 | * | 31/01/2020 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.10.2: ID: 669910 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.10.1: ID: 643460 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response time has been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.10.0: ID: 614390 / Support ID: 400257973 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.9.0: ID: 618255 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(330) Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.10.1 | * | 16/05/2019 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.10.1: ID: 643460 data sheet V1.141 See chapture "Version history" in the data sheet. i.a. calculation of Safety response timehas been updated. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.10.0: ID:614390 / Support ID: 400257973 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.9.0: ID: 618255 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(330) Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configurationdescription changed: No Firmware changed: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization oftiming parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting with this version, the modulealso supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModuleIDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.10.0 | * | 06/12/2018 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.10.0: ID: 614390 / Support ID: 400257973 Sporadic errors 114982, 102914, 120065, 110385 Sporadic errors 114982, 102914, 120065, 110385 have been fixed Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(331) Version 1.10.9.0: ID: 618255 logger entry 112174, 108078 Logger entry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(330) Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type ofmodule in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.9.0 | * | 08/11/2018 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.9.0: ID: 618255 logger entry 112174, 108078 Loggerentry 112174, 108078 could happen sporadically with large projects. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(330) Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now itis possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.1.0 | * | 19/03/2018 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.1.0: ID: 541500 Improve the description section in the OSDD files Improve the description section in the OSDD files Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 570650 / Support ID: 400236267 set SafeOutputOKs even when channel is not mapped SafeOutputOKs are set now even whenchannel is not mapped Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 582210 Provide CRC of the Firmware Provide CRC of the Firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(325) Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmwarechanged: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changedmanual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmwarechanged: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting with this version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlockof SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption of module configuration file release 1.6 Channel descriptionchanged: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||
| Version | Sprog | Operativ system | Dato | Størrelse | Type | Download |
| 1.10.0.6 | * | 04/10/2017 | 2 MB | EXE | AS4_HW_X20SO2530.exe | |
| Beskrivelse |
V4.0 HW Upgrade (X20SO2530) Revision information X20SO2530 Version 1.10.0.6: ID: 533080 Add blackout mode Add blackout mode Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533165 New channel for ConnectionValid New channel for ConnectionValid Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 533185 Update ECAD data Update ECAD data Channel description changed: No Configuration description changed: Yes Firmwarechanged: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.2: ID: 483060 Added coated type of module in help Added coated type of module in help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.10.0.1: ID: 470595 Support of release 1.10 including openSAFETY 1.5 Support of release 1.10 including openSAFETY 1.5 with easier parametrization of timing parameters Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 470600 changed manual verion to 1.100 changed manual verion to 1.100 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300), 7\53765_1.fw(320) Version 1.9.0.0: ID: 399900 Update Online Help Update Online Help V1.90 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 413850 SafeModuleID >300 Now it is possible to set SafeModuleID greater than 300, like described in the AS-Help. Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 413950 Channel-Status-Info ON The default value of the Channel-Status information is now ON. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291), 4\53765_1.fw(300) Version 1.6.0.8: ID: 388425 The module also supports SafetyRelease 1.8 Starting with this version, the module also supports SafetyRelease 1.8 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.7: ID: 339270 internal Adjustments internal Adjustments Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 3\53765_1.fw(291) Version 1.6.0.5: ID: 335455 The module also supports SafetyRelease 1.7 Starting withthis version, the module also supports SafetyRelease 1.7 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 335460 / Support ID: 400083263 unlock of SafeModule IDs > 300 SafeModule IDs up to 1023 are now unlocked Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.6.0.0: ID: 314065 Adaption of module configuration file release 1.6 Adaption ofmodule configuration file release 1.6 Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 3\53765_1.fw(291) Version 1.5.0.4: ID: 303395 Support of AutomationStudio 4.0 Support of AutomationStudio 4.0 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 3\53765_1.fw(291) Version 1.5.0.1: ID: 294345 First Official Release First Official Release Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 3\53765_1.fw(291) |
|||||