DWL@DWL10000250509

Version Sprog
Operativ system
Dato
Størrelse
Type Download
1.4.0.0 * 03/02/2022 973 KB EXE AS4_HW_X20CM1941.exe
Beskrivelse V4.0 HW Upgrade (X20CM1941)

Revision information X20CM1941

Version 1.4.0.0:

ID: 688530
Support HW-variant 3
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(100), 1\7813_3.fw(100)

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed:yes
Firmware changed: no

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.1.3:

ID: 322660
Extended EPLAN data
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:No
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version 1.1.1.2:

ID: 257105
Serial number will be displayed correctly
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version 1.1.0.0:

ID: 241800 / Support ID: 400052686
Duty Cycle of AB signalsporadically not correct
Due to a faulty implementation of the ABR-simulation there is the possibility of invalid AB signals (depending on the velocity).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(7)
Version Sprog
Operativ system
Dato
Størrelse
Type Download
1.3.0.0 * 23/07/2021 409 KB EXE AS4_HW_X20CM1941.exe
Beskrivelse V4.0 HW Upgrade (X20CM1941)

Revision information X20CM1941

Version 1.3.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.1.3:

ID: 322660
Extended EPLAN data
Channel description changed:No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version 1.1.1.2:

ID: 257105
Serial number will be displayed correctly
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version 1.1.0.0:

ID: 241800 / Support ID: 400052686
Duty Cycle of AB signal sporadically not correct
Due to a faulty implementation of the ABR-simulation there is the possibility of invalid AB signals (depending on the velocity).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(7)
Version Sprog
Operativ system
Dato
Størrelse
Type Download
1.2.0.0 * 25/10/2019 406 KB EXE AS4_HW_X20CM1941.exe
Beskrivelse V4.0 HW Upgrade (X20CM1941)

Revision information X20CM1941

Version 1.2.0.0:

ID:
Adaptations for Automation Studio 4.8
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.1.1.3:

ID: 322660
ExtendedEPLAN data
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version 1.1.1.2:

ID: 257105
Serial number will bedisplayed correctly
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version 1.1.0.0:

ID: 241800 / Support ID: 400052686
Duty Cycle of AB signal sporadically not correct
Due to a faulty implementation of the ABR-simulation there is the possibility of invalid AB signals (depending on the velocity).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(7)
Version Sprog
Operativ system
Dato
Størrelse
Type Download
1.1.1.3 * 12/09/2013 426 KB EXE AS4_HW_X20CM1941.exe
Beskrivelse V4.0 HW Upgrade (X20CM1941)

Revision information X20CM1941

Version 1.1.1.3:

ID: 322660
Extended EPLAN data
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version 1.1.1.2:

ID: 257105
Serial number will be displayed correctly
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(8)

Version1.1.0.0:

ID: 241800 / Support ID: 400052686
Duty Cycle of AB signal sporadically not correct
Due to a faulty implementation of the ABR-simulation there is the possibility of invalid AB signals (depending on the velocity).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7813_1.fw(4), 1\7813_2.fw(7)
Loading
Tilbage til listen

Vælg venligst land og sprog

B&R Logo