V4.0 HW Upgrade (X67BC8321.L12)

DWL@DWL10000303946

Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.17.0.0 * 2025-05-14 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.17.0.0:

ID: RKFY-9500
Added capability to disable Fast Link Down detection
In the event of interferences on the network cable, the active Fast Link Down Detection very quickly leads to a complete loss of the link and thus to a failure of all subsequent stations. The Fast Link Down Detection can now be deactivated, which means that minor faults on the cable have less impact.

Channel description changed: No
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\7966_1.fw(438), 1\7966_3.fw(438), 1\7966_4.fw(438), 1\7966_5.fw(438), 1\7966_6.fw(438), 1\7966_7.fw(438)

Version 2.16.0.0:

ID: 772415
Continuous product improvement
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(436), 1\7966_3.fw(436), 1\7966_4.fw(436), 1\7966_5.fw(436), 1\7966_6.fw(436),1\7966_7.fw(436)

Version 2.15.0.0:

ID: 758510
Optimization of asynchronous register access
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware:1\7966_1.fw(433), 1\7966_3.fw(433), 1\7966_4.fw(433), 1\7966_5.fw(433), 1\7966_6.fw(433), 1\7966_7.fw(433)

Version 2.14.0.0:

ID: 712665
POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438)
POWERLINK Security Vulnerability (CVE-2020-13987)
The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets.

POWERLINK Security Vulnerability (CVE-2020-17438)
The POWERLINK IP stack was affected by a security vulnerability impacting fragmentedpacket reassembly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 720890
NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(432), 1\7966_3.fw(432), 1\7966_4.fw(432), 1\7966_5.fw(432), 1\7966_6.fw(432), 1\7966_7.fw(432)

Version 2.12.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 2.11.1.0:

ID: 695110
Support for automatic DNA configuration from AS 4.9.1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 695280
Module documentation revised
Data sheet V2.38
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7966_1.fw(430), 1\7966_3.fw(430), 1\7966_4.fw(430), 1\7966_5.fw(430), 1\7966_6.fw(430), 1\7966_7.fw(430)

Version 2.11.0.0:

ID: 519270
Accessing non-cyclic registers with AsIOAccwhile ModuleOk = FALSE prevents module from starting/communicating
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 631020
ModuleOk of IO module FALSE after warm restart even though the module is working as expected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 663630
DNA: Hub of PLK BC active until first IDENT_REQUEST
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 663720
Adaptations forAutomation Studio 4.8
Channel description changed: No
Configurationdescription changed: No
Firmware changed: No

ID: 666180
Module documentation revised
Data sheet V2.37
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7966_1.fw(430), 1\7966_3.fw(430), 1\7966_4.fw(430), 1\7966_5.fw(430), 1\7966_6.fw(430), 1\7966_7.fw(430)

Version 2.10.0.0:

ID: 624175
Optimization of the firmware update process
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(428), 1\7966_3.fw(428), 1\7966_4.fw(428),1\7966_5.fw(428), 1\7966_6.fw(428), 1\7966_7.fw(428)

Version 2.9.0.0:

ID: 602705
Ring redundancy: Cannot address the CN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 611630
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624130
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 624385
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(427), 1\7966_3.fw(427), 1\7966_4.fw(427), 1\7966_5.fw(427), 1\7966_6.fw(427)

Version 2.8.0.0:

ID: 603160
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 608585
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(426), 1\7966_3.fw(426), 1\7966_4.fw(426), 1\7966_5.fw(426), 1\7966_6.fw(426)

Version 2.7.0.0:

ID: 574890
Temporary toggling of data point ModuleOk if I/O module fails
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(424), 1\7966_3.fw(424), 1\7966_4.fw(424), 1\7966_5.fw(424), 1\7966_6.fw(424)

Version 2.6.0.0:

ID: 574205
Optimization of boot procedure for hardware variant 5 und 6
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(423), 1\7966_3.fw(423), 1\7966_4.fw(423), 1\7966_5.fw(423), 1\7966_6.fw(423)

Version 2.5.6.0:

ID: 564615
Optimization the boot up for hardware variant 5
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(422), 1\7966_3.fw(422), 1\7966_4.fw(422), 1\7966_5.fw(422)

Version 2.5.5.0:

ID: 548065
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(421), 1\7966_3.fw(421), 1\7966_4.fw(421), 1\7966_5.fw(421)

Version 2.5.4.0:

ID: 539100
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(419), 1\7966_3.fw(419), 1\7966_4.fw(419)

Version 2.5.3.0:

ID: 517445
SDO streaming connection via UDP is not always established when PLC and BC are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(417), 1\7966_3.fw(417), 1\7966_4.fw(417)

Version 2.5.2.0:

ID: 271540
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(415), 1\7966_3.fw(415), 1\7966_4.fw(415)

Version 2.5.0.0:

ID: 431950
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 465250
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 467335
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468515
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\7966_1.fw(413), 1\7966_3.fw(413), 1\7966_4.fw(413)

Version 2.3.0.0:

ID: 428150
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 437925
AS4.2.5 modifications
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID:455930
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(411), 1\7966_3.fw(411), 1\7966_4.fw(411)

Version 2.2.0.0:

ID: 338175
Expansion for AR to detect the Ethernet port being used
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 380760
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 431210
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(400), 1\7966_3.fw(400), 1\7966_4.fw(400)

Version 2.1.0.0:

ID: 393570
Upgrade 2.0.0.0 leads to a problem with WinIO switchboard
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID: 396220
X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed.
When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change.
The data point diechange when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing.
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(300), 1\7966_3.fw(300), 1\7966_4.fw(300)

Version 2.0.0.0:

ID: 385125
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(210), 1\7966_3.fw(210), 1\7966_4.fw(210)

Version 1.3.5.0:

ID: 328265
Firmware of special I/O modules on POWERLINK bus controllers not updating reliably when using an X2X cycle time less than 400 µs
This problem occurs if the following conditions are met at the same time:
- Firmware being updated on I/O modules on a POWERLINK bus controller
- Some I/O modules using an older revision
Current I/O module revisions are not affected. There is therefore no problem if a customer is replacing an old I/O module with a new I/O module on an existing system.
- X2X cycle time < 400 us
- Short X2X cable length configured
This problem does not occur if longer cable lengths are configured (e.g. the default value of 1000 m).
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(170), 1\7966_3.fw(170), 1\7966_4.fw(170)

Version 1.3.4.0:

ID: 299875
Expansion: Link- selector flag
New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No

ID:310065
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(168), 1\7966_3.fw(168), 1\7966_4.fw(168)

Version 1.3.3.0:

ID: 302500
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(167), 1\7966_3.fw(167), 1\7966_4.fw(167)

Version 1.3.2.0:

ID: 295655
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(165), 1\7966_3.fw(165), 1\7966_4.fw(165)

Version 1.3.1.0:

ID: 288750
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 290070
New Hardwarevariant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(163), 1\7966_3.fw(163), 1\7966_4.fw(163)

Version 1.3.0.0:

ID: 240940
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration descriptionchanged: Yes
Firmware changed: Yes

ID: 274795
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(160), 1\7966_3.fw(160)

Version 1.2.1.0:

ID: 247260
DNA  runup upgraded
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(152), 1\7966_3.fw(152)

Version 1.2.0.0:

ID: 245095
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (DynamicNode Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\7966_1.fw(150), 1\7966_3.fw(150)

Version 1.0.8.0:

ID: 218490
Extensions and Bugfixes
- Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1
- Support of PollResponse-Chaining
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(145)

Version 1.0.7.0:

ID: 214340
Extensions and Bugfixes
- In systems with high X2X load it happened thatIO modules were not restarted when the CPU did a warmstart (A&P 211805)
- Activation of MultipleRead/Write feature for faster startup after configuration change
- Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed
- Number of configuration entries per IO module changed from 100 to 155
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(144)

Version 1.0.6.0:

ID: 210955
Extensions and Bugfixes
- Error correction for operation in Powerlink V1 networks (A&P 210765)
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(143)

Version 1.0.5.0:

ID: 210215
Extensions and Bugfixes
- New ASICS will be set to 3mA output current (A&P 182905)
- Optimization of SDO communication (unnecessary acknowledges removed)
- Support of commands ReadMultipleParameter / WriteMultipleParameter
- NodeID assignment by digital inputs supported (NodeId 241 and 242)
- Minor corrections certification
- ASnd frames with unknown ServiceID could disturb the BC (only possible with 3rd party MN)
- Access to not existing objects in OD could cause firmware crash
- When running X2X cycle times <200 us the X2X Bus was not working correctly (A&P 190630)
- When in state PREOP_2 no SoC is received for 10sec the BC will fall back in PREOP_1
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\7966_1.fw(142)

Version 1.0.4.1:

ID: 183285
New info-/diagnostic data points, new FW 1.39 for signal filter and corrections
New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7966_1.fw(141)

Version 1.0.3.0:

ID: 173310
Extensions and Bugfixes
- Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987)
- Optimizations for operation in 200us networks
- 2 nodes with thesame node number generated disturbance on the network (A&P 166040)
- Functions for a new firmware download mechanism implemented (A&P 168537)
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7966_1.fw(138)

Version 1.0.2.0:

ID: 164640
Extensions
- Extensions for operation with Safety
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\7966_1.fw(136)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.15.0.0 * 2022-10-13 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.15.0.0:

ID: 758830
Optimization of asynchronous register access
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(433), 1\43278_2.fw(433), 1\43278_3.fw(433), 1\43278_4.fw(433)

Version 2.14.0.0:

ID: 737330
NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 737335
POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438)
POWERLINK Security Vulnerability (CVE-2020-13987)
The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets.

POWERLINK Security Vulnerability (CVE-2020-17438)
The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(432), 1\43278_2.fw(432), 1\43278_3.fw(432), 1\43278_4.fw(432)

Version 2.11.1.0:

ID: 697875
Support for automatic DNA configuration from AS 4.9.1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(430), 1\43278_2.fw(430), 1\43278_3.fw(430), 1\43278_4.fw(430)

Version 2.11.0.0:

ID: 664430
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 664460
DNA: Hub of PLK BC active until first IDENT_REQUEST
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665785
ModuleOk of IO module FALSE after warm restart even though the module is working as expected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665875
Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666155
Module documentation revised
Data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\43278_1.fw(430), 1\43278_2.fw(430), 1\43278_3.fw(430), 1\43278_4.fw(430)

Version 2.9.3.0:

ID: 639725 / Support ID: 400268096
Alignment of ASoutput according to the FieldBusDesigner
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.9.0.0:

ID: 624525
L/A IF LED permanently green although Ethernet activity is taking place on the bus
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 625035
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629045
Ring redundancy: Cannot address the CNthat closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629120
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629195
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.8.0.0:

ID: 619235
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 619265
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621710
Display of further diagnostic data points in the I / O mapping of theX2X interface from the X67 bus controller
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 624315
Firmwareupdate of X2XLink module at POWERLINK Stations doesnot work since H4.34
Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming.

Problem occurs on BC and SL:
X20BC0083 X20cBC0083 &lt; HW-Upgrade 2.2.0.0
X20BC1083 X20cBC1083 &lt; HW-Upgrade 2.5.0.0
X20BC8083 X20cBC8083 &lt; HW-Upgrade 2.5.0.0
X20BC8084 X20cBC8084 &lt; HW-Upgrade 2.5.0.0
X20SL8101 X20cSL8101
X67BC81RT.L12 &lt; HW-Upgrade 2.5.0.0
X67BC8321-1
X67BC8331
X67BC8513.L12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(426), 1\43278_2.fw(426), 1\43278_3.fw(426), 1\43278_4.fw(426)

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421), 1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after longtime takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468195 / Support ID: 400177243
X2X FW updateof several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468200 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID: 460140 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID: 385270 / Support ID: 400132264
hwc, hwx adaption
Channel address adapted for fieldbusdesigner
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers nolonger achieving Operationalmode after multiple power-on cycles
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware for hardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167), 1\43278_4.fw(167)

Version1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID: 289030
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2Xand NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem in the MAC
effect: causes a losing connection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 268580
New hardware variant
New hardware variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
- support for Simulation device added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID: .
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(144)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.14.0.0 * 2021-10-25 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.14.0.0:

ID: 737330
NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 737335
POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438)
POWERLINK Security Vulnerability (CVE-2020-13987)
The POWERLINKIP stack was affected by a security vulnerability impacting the checksum calculation of TCP/UDP packets.

POWERLINK Security Vulnerability (CVE-2020-17438)
The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(432), 1\43278_2.fw(432), 1\43278_3.fw(432), 1\43278_4.fw(432)

Version 2.11.1.0:

ID: 697875
Support for automatic DNA configuration from AS 4.9.1
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(430), 1\43278_2.fw(430), 1\43278_3.fw(430), 1\43278_4.fw(430)

Version 2.11.0.0:

ID: 664430
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 664460
DNA: Hub of PLK BC active until first IDENT_REQUEST
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665785
ModuleOk of IO module FALSE after warm restart even though the module is working as expected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665875
Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666155
Module documentation revised
Data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\43278_1.fw(430), 1\43278_2.fw(430), 1\43278_3.fw(430), 1\43278_4.fw(430)

Version 2.9.3.0:

ID: 639725 / Support ID: 400268096
Alignment of AS output according to the FieldBusDesigner
Channeldescription changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.9.0.0:

ID: 624525
L/A IF LED permanently green although Ethernet activity is taking place on thebus
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 625035
Optimization of hubbehavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629045
Ring redundancy: Cannot address the CN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629120
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629195
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.8.0.0:

ID: 619235
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes

ID: 619265
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621710
Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 624315
Firmwareupdate of X2XLink module atPOWERLINK Stations does not work since H4.34
Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming.

Problem occurs on BC and SL:
X20BC0083 X20cBC0083 &lt; HW-Upgrade 2.2.0.0
X20BC1083 X20cBC1083 &lt; HW-Upgrade 2.5.0.0
X20BC8083 X20cBC8083&lt; HW-Upgrade 2.5.0.0
X20BC8084 X20cBC8084 &lt; HW-Upgrade 2.5.0.0
X20SL8101 X20cSL8101
X67BC81RT.L12 &lt; HW-Upgrade 2.5.0.0
X67BC8321-1
X67BC8331
X67BC8513.L12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(426), 1\43278_2.fw(426), 1\43278_3.fw(426), 1\43278_4.fw(426)

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421), 1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 / Support ID: 400205694
safety modules notswitching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / SupportID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FW updates
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 468195 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 468200 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.bySL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID: 460140 /Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID: 385270/ Support ID: 400132264
hwc, hwx adaption
Channel address adapted for fieldbusdesigner
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / SupportID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware for hardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- UpgradeVersion 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channeldescription changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167), 1\43278_4.fw(167)

Version 1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
Thefirmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID: 289030
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem in the MAC
effect: causes a losing connection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 268580
New hardware variant
New hardware variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
- support for Simulation device added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID: .
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(144)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.11.1.0 * 2020-08-24 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.11.1.0:

ID: 697875
Support for automatic DNA configuration from AS 4.9.1
Channel description changed: No
Configurationdescription changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(430), 1\43278_2.fw(430), 1\43278_3.fw(430), 1\43278_4.fw(430)

Version2.11.0.0:

ID: 664430
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 664460
DNA: Hub of PLK BC active until first IDENT_REQUEST
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 665785
ModuleOk of IO module FALSE after warm restart even though the module is working as expected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665875
Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 666155
Module documentation revised
Data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\43278_1.fw(430), 1\43278_2.fw(430), 1\43278_3.fw(430), 1\43278_4.fw(430)

Version 2.9.3.0:

ID: 639725 / Support ID: 400268096
Alignment of AS output according to the FieldBusDesigner
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.9.0.0:

ID: 624525
L/A IF LED permanently green although Ethernet activity is taking place on the bus
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 625035
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629045
Ring redundancy:Cannot address the CN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629120
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629195
Shortened preamble of Ethernetframe leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.8.0.0:

ID: 619235
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 619265
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621710
Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 624315
Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34
Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming.

Problem occurs on BC and SL:
X20BC0083 X20cBC0083 &lt; HW-Upgrade 2.2.0.0
X20BC1083 X20cBC1083 &lt; HW-Upgrade 2.5.0.0
X20BC8083 X20cBC8083 &lt; HW-Upgrade 2.5.0.0
X20BC8084 X20cBC8084 &lt; HW-Upgrade 2.5.0.0
X20SL8101 X20cSL8101
X67BC81RT.L12 &lt; HW-Upgrade 2.5.0.0
X67BC8321-1
X67BC8331
X67BC8513.L12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(426), 1\43278_2.fw(426), 1\43278_3.fw(426), 1\43278_4.fw(426)

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421), 1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FWupdates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468195 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468200 / Support ID: 400178654
Safety modules inconnection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed:No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID: 460140 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID: 385270 /Support ID: 400132264
hwc, hwx adaption
Channel address adapted forfieldbusdesigner
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware forhardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;-RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a highload on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronouscommunication caused the safety-IO to stop.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167), 1\43278_4.fw(167)

Version 1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID: 289030
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem in the MAC
effect: causes a losing connection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 268580
New hardware variant
New hardware variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
- support for Simulation device added
Channeldescription changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID: .
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(144)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.11.0.0 * 2020-02-20 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.11.0.0:

ID: 664430
Adaptations for Automation Studio 4.8
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 664460
DNA: Hub of PLK BCactive until first IDENT_REQUEST
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665785
ModuleOk of IO module FALSE after warm restart even though the module is working as expected
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 665875
Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 666155
Module documentation revised
Data sheet V2.08
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\43278_1.fw(430), 1\43278_2.fw(430), 1\43278_3.fw(430), 1\43278_4.fw(430)

Version 2.9.3.0:

ID: 639725 / Support ID: 400268096
Alignment of AS output according to the FieldBusDesigner
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427),1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.9.0.0:

ID: 624525
L/A IF LED permanently green although Ethernet activity is taking place on the bus
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 625035
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629045
Ring redundancy: Cannot address the CN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629120
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629195
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.8.0.0:

ID: 619235
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 619265
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621710
Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 624315
Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34
Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming.

Problem occurs on BC and SL:
X20BC0083 X20cBC0083 &lt; HW-Upgrade 2.2.0.0
X20BC1083 X20cBC1083 &lt; HW-Upgrade 2.5.0.0
X20BC8083 X20cBC8083 &lt; HW-Upgrade 2.5.0.0
X20BC8084 X20cBC8084 &lt; HW-Upgrade 2.5.0.0
X20SL8101 X20cSL8101
X67BC81RT.L12 &lt; HW-Upgrade 2.5.0.0
X67BC8321-1
X67BC8331
X67BC8513.L12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(426), 1\43278_2.fw(426), 1\43278_3.fw(426), 1\43278_4.fw(426)

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421),1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDPis not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468195 / SupportID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468200 / Support ID: 400178654
Safetymodules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID:460140 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID: 385270 / Support ID: 400132264
hwc, hwx adaption
Channel address adapted for fieldbusdesigner
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305 / Support ID: 400129274
Uncommon X2X settingscause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware for hardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When therewas a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167),1\43278_4.fw(167)

Version 1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID: 289030
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem in the MAC
effect: causes a losingconnection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 268580
New hardwarevariant
New hardware variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
- support for Simulation device added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID: .
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed:No
Firmware: 1\43278_1.fw(144)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.9.3.0 * 2019-04-12 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.9.3.0:

ID: 639725 / Support ID: 400268096
Alignment of AS output according to the FieldBusDesigner
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.9.0.0:

ID: 624525
L/A IF LED permanently green although Ethernet activity is taking place on the bus
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 625035
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629045
Ring redundancy: Cannot addressthe CN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629120
DNA: BC as head-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629195
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware:1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.8.0.0:

ID: 619235
DNA: PLK hub forwarding for thenext node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID:619265
Outputs of I/O modules behind the bus coupler not working in somecases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621710
Display of further diagnostic data points in the I / O mappingof the X2X interface from the X67 bus controller
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 624315
Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34
Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming.

Problem occurs on BC and SL:
X20BC0083 X20cBC0083 &lt; HW-Upgrade 2.2.0.0
X20BC1083 X20cBC1083 &lt; HW-Upgrade 2.5.0.0
X20BC8083 X20cBC8083 &lt; HW-Upgrade 2.5.0.0
X20BC8084 X20cBC8084 &lt; HW-Upgrade 2.5.0.0
X20SL8101 X20cSL8101
X67BC81RT.L12 &lt; HW-Upgrade 2.5.0.0
X67BC8321-1
X67BC8331
X67BC8513.L12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(426), 1\43278_2.fw(426), 1\43278_3.fw(426), 1\43278_4.fw(426)

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421), 1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always establishedwhen PLC and SafeLogic are booted together.
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468195 / Support ID: 400177243
X2X FWupdate of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468200 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed:No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID: 460140 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID: 385270 / Support ID: 400132264
hwc, hwx adaption
Channel address adapted for fieldbusdesigner
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware for hardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontrollerwas interrupted. Restarting the boscontroller restored communication. Loss ofasynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restartingthe boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167), 1\43278_4.fw(167)

Version 1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem withFW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID: 289030
Certain X2Xconfigurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem in the MAC
effect: causes a losing connection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 268580
New hardware variant
New hardwarevariant 4
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
- support for Simulation device added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID: .
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(144)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.9.0.0 * 2019-03-13 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.9.0.0:

ID: 624525
L/A IF LED permanently green although Ethernet activity is taking place on the bus
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 625035
Optimization of hub behavior
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629045
Ring redundancy: Cannot address the CN that closes the ring
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629120
DNA: BC ashead-end station switching hub off again
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 629195
Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(427), 1\43278_2.fw(427), 1\43278_3.fw(427), 1\43278_4.fw(427)

Version 2.8.0.0:

ID: 619235
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 619265
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621710
Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 624315
Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34
Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming.

Problem occurs on BC andSL:
X20BC0083 X20cBC0083 &lt; HW-Upgrade 2.2.0.0
X20BC1083 X20cBC1083 &lt; HW-Upgrade 2.5.0.0
X20BC8083 X20cBC8083 &lt; HW-Upgrade 2.5.0.0
X20BC8084 X20cBC8084 &lt; HW-Upgrade 2.5.0.0
X20SL8101 X20cSL8101
X67BC81RT.L12 &lt; HW-Upgrade 2.5.0.0
X67BC8321-1
X67BC8331
X67BC8513.L12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(426), 1\43278_2.fw(426), 1\43278_3.fw(426), 1\43278_4.fw(426)

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421), 1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 /Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468195 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468200 / Support ID: 400178654
Safety modules in connection with PLK BCs, withonly input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID: 460140 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID: 385270 / Support ID: 400132264
hwc, hwx adaption
Channel address adapted for fieldbusdesigner
Channeldescription changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes

ID: 439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305 / Support ID:400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware for hardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815 / Support ID: 400097674
POWERLINKV1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware:1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronouscommunication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167), 1\43278_4.fw(167)

Version 1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID: 289030
Certain X2X configurationsdon't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem inthe MAC
effect: causes a losing connection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 268580
New hardware variant
New hardware variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
- support for Simulation device added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID: .
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(144)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.8.0.0 * 2018-12-12 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.8.0.0:

ID: 619235
DNA: PLK hub forwarding for the next node not enabled in rare cases
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 619265
Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 621710
Display of further diagnostic data points in the I / O mapping of the X2X interface from the X67 bus controller
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 624315
Firmwareupdate of X2XLink module at POWERLINK Stations does not work since H4.34
Since H4.34 the firmware update of X2XLink modules connected to X67BC8321-1did not work, if they are connected to POWERLINK-Buscontrollers that have no explicit enable for streaming.

Problem occurs on BC and SL:
X20BC0083 X20cBC0083 &lt; HW-Upgrade 2.2.0.0
X20BC1083 X20cBC1083 &lt; HW-Upgrade 2.5.0.0
X20BC8083 X20cBC8083 &lt; HW-Upgrade 2.5.0.0
X20BC8084 X20cBC8084 &lt; HW-Upgrade 2.5.0.0
X20SL8101 X20cSL8101
X67BC81RT.L12 &lt; HW-Upgrade 2.5.0.0
X67BC8321-1
X67BC8331
X67BC8513.L12
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(426), 1\43278_2.fw(426), 1\43278_3.fw(426), 1\43278_4.fw(426)

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421), 1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468195 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 468200 / Support ID: 400178654
Safety modules in connection withPLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID: 460140 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed:No
Configuration description changed: No
Firmware changed: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID: 385270 / Support ID: 400132264
hwc, hwx adaption
Channel address adapted for fieldbusdesigner
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID:439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305/ Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware for hardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815 / Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167), 1\43278_4.fw(167)

Version 1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID: 289030
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channeldescription changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configurationdescription changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem in the MAC
effect: causes a losing connection
Channel description changed: No
Configuration description changed: No
Firmwarechanged: Yes

ID: 268580
New hardware variant
New hardware variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior on X2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
- new objects: 20A3h and 2000h/9
- support for Simulation device added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID: .
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(144)
Version Språk
Operativ system
Datum
Storlek
Typ Ladda ner
2.5.5.0 * 2017-09-08 3 MB EXE AS4_HW_X67BC8321.L12.exe
Beskrivning V4.0 HW Upgrade (X67BC8321.L12)

Revision information X67BC8321.L12

Version 2.5.5.0:

ID: 551150
Startup time optimizations
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(421), 1\43278_2.fw(421), 1\43278_3.fw(421), 1\43278_4.fw(421)

Version 2.5.4.0:

ID: 540350 / Support ID: 400202320
BC sporadically not going into Operational due to X2X-bus problems at startup
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(419), 1\43278_2.fw(419), 1\43278_3.fw(419), 1\43278_4.fw(419)

Version 2.5.3.0:

ID: 523585 / Support ID: 400205694
safety modules not switching to operational state
SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(417), 1\43278_2.fw(417), 1\43278_3.fw(417), 1\43278_4.fw(417)

Version 2.5.2.0:

ID: 493935 / Support ID: 400103115, 400101850, 400154063, 400190752
First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(415), 1\43278_2.fw(415), 1\43278_3.fw(415), 1\43278_4.fw(415)

Version 2.5.0.0:

ID: 468190
optimization of X2X FW updates
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468195 / Support ID: 400177243
X2X FW update of several X2X modules is not working
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 468200 / Support ID: 400178654
Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL
Channel description changed: No
Configuration descriptionchanged: No
Firmware changed: Yes

ID: 468575
CiR support
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(413), 1\43278_2.fw(413), 1\43278_3.fw(413), 1\43278_4.fw(413)

Version 2.2.1.0:

ID: 460140 / Support ID: 400168329
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 460260 / Support ID: 400150525
Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(412), 1\43278_2.fw(412), 1\43278_3.fw(412), 1\43278_4.fw(412)

Version 2.1.0.0:

ID:385270 / Support ID: 400132264
hwc, hwx adaption
Channel address adapted for fieldbusdesigner
Channel description changed: Yes
Configuration description changed: No
Firmware changed: No

ID: 439135 / Support ID: 400150496
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 439240 / Support ID: 400128436
I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(400), 1\43278_2.fw(400), 1\43278_3.fw(400), 1\43278_4.fw(400)

Version 2.0.0.1:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 392930 / Support ID: 400138511
X2X communication revised
A new firmware for hardware variant 3 (BC-Part) was released.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(211), 1\43278_2.fw(211), 1\43278_3.fw(211), 1\43278_4.fw(211)

Version 2.0.0.0:

ID: 390305 / Support ID: 400129274
Uncommon X2X settings cause permanent boot of bus controller
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(210), 1\43278_2.fw(210), 1\43278_3.fw(210), 1\43278_4.fw(210)

Version 1.3.4.0:

ID: 310815/ Support ID: 400097674
POWERLINK V1: Bug-fix for Up/Downgrade
POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 311035 / Support ID: 400051206
Expansion: Link- selector flag
New datapoints:&lt;br/&gt;- RedundancyFirstLinkState&lt;br/&gt;- RedundancySecondLinkState
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(168), 1\43278_2.fw(168), 1\43278_3.fw(168), 1\43278_4.fw(168)

Version 1.3.3.0:

ID: 305175 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 305180 / Support ID: 400094368
ACOPOSmulti with SafeMC, asynchronous communication lost
When there was a high load on the CPU, asynchronous communication to the buscontroller wasinterrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop.
Channel descriptionchanged: No
Configuration description changed: No
Firmware changed:Yes
Firmware: 1\43278_1.fw(167), 1\43278_2.fw(167), 1\43278_3.fw(167), 1\43278_4.fw(167)

Version 1.3.2.0:

ID: 299000 / Support ID: 400090781
Problem with FW-Update of IO modules on Powerlink buscontrollers
The firmware update of IO modules does not work in certain configurations.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(165), 1\43278_2.fw(165), 1\43278_3.fw(165), 1\43278_4.fw(165)

Version 1.3.1.0:

ID:289030
Certain X2X configurations don't work
In very rare I/O constellations, the X2X modules don't start
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\43278_1.fw(163), 1\43278_2.fw(163), 1\43278_3.fw(163), 1\43278_4.fw(163)

Version 1.3.0.0:

ID: 277190
Support of 'Multiple Asynchronous Send'
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 277760
New X2X datapoints
- NettimeOffsetX2X and NettimeX2X
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(160), 1\43278_2.fw(160), 1\43278_3.fw(160), 1\43278_4.fw(160)

Version 1.2.3.0:

ID: 268080 / Support ID: 400072663
Error in FPGA cause a problem in the MAC
effect: causes a losing connection
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 268580
New hardware variant
New hardware variant 4
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware:1\43278_1.fw(154), 1\43278_2.fw(154), 1\43278_3.fw(154), 1\43278_4.fw(154)

Version 1.2.2.0:

ID: 246365
DNA support; Update behavior onX2X bus of the BC improved
- DNA support (Dynamic Node Allocation)
- faster updating of modules with big FW files on the X2X bus of the BC
-new objects: 20A3h and 2000h/9
- support for Simulation device added
Channel description changed: Yes
Configuration description changed: Yes
Firmware changed: Yes
Firmware: 1\43278_1.fw(152), 1\43278_2.fw(152), 1\43278_3.fw(152)

Version 1.0.3.0:

ID: 240470 / Support ID:.
Correction of X67BCOnboard Compatible Code
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\43278_1.fw(144)